My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3012 34TH PL 2019-01-09
>
Address Records
>
34TH PL
>
3012
>
3012 34TH PL 2019-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 10:06:08 AM
Creation date
1/9/2019 10:06:02 AM
Metadata
Fields
Template:
Address Document
Street Name
34TH PL
Street Number
3012
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Unit E Townhome Polygon Northwest Company <br /> Eclipse Jamie Aubrey <br /> Everett,Wa (425)586-7700 <br /> Heating System Type: O Forced Air Furnace 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Inslrnrrion`. Design Temperature Difference(AT) 47 <br /> Everett IC <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 1,163 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 9,886 <br /> Glazing and Doors U-Factor X Area = UA <br /> 0.30 127 38.13 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> li;:•ii;1.lw"s <br /> R-49 �.: i 0.026 579 15.05 <br /> l J <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions <br /> No Vaulted Ceilings in this project. V --- <br /> Above Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions 0.056 590 33.04 <br /> • <br /> Lit 21 <br /> Floors U-Factor Area UA <br /> Instructions0.029 533 15.46 <br /> R 30 ;i <br /> Below Grade Walls(see Figure 1) U-Factor Area UA <br /> Iin;l13n:ho •., __.._ <br /> No Below Grade Walls in this pioject. V --- --- <br /> In•:Irnr.tion:• (see Figure 1) ly <br /> Slab F-Factor LeUA <br /> Below Grade <br /> No Slab Below Grade in this project. --- <br /> Slab on Grade(see Figure 1) F-Factor Len.th UA <br /> nc.tinctioiis - 0.540 22 11.88 <br /> 5.10 Perimeter <br /> J <br /> Location of Ducts <br /> r'r"coo"' - Duct Leakage Coefficient <br /> Conditioned Space V: <br /> 1.00 <br /> Sum of UA 113.56 <br /> Envelope Heat Load 5,337 Btu/Hour <br /> Figure 1. Sum of UAX AT <br /> Air Leakage Heat Load 5,018 Btu/Hour <br /> VolumeX 0.6X AT X.018 <br /> Above Grade Building Design Heat Load 10,355 Btu/Hour <br /> _.. <br /> �- Air Leakage+Envelope Heat Loss <br /> i' Betow Grade y'* <br /> Building and Duct Heat Load 10,355 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 14,497 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.