Laserfiche WebLink
���h�j I— <br /> �� �� ���� V <br /> � �' W <br /> H <br /> ��,�4192�� ��� = N <br /> °�a��� v � . <br /> SYMBOL LIST GENERAL NOTES <br /> 2015 WASHINGTON STATE ENERGY CODE NOTES °C � � <br /> � o <br /> � � Q � � - <br /> � ° oo � a�i <br /> � SYMBOL ABBV. DESCRIPTION a� v r, '� �-.- <br /> SYMBOL ABBV. DESCRIPTION PROTECT ALL DUCT OPENINGS OF FIRE RATED ASSEMBLIES PER I.B.C. 716. NOTE: ITEMS IN (PARENTHESIS) REFERENCE CODE SECTIONS FROM THE 2015 � fl- o m � <br /> WASHWGTON STATE ENERGY CODE. F- � 'a, o o � � <br /> C CONDENSATE INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF SHAFT � � <br /> C ELECT. ELECTRICAL .� i � �, � �,�_. �� ¢ � <br /> ENCLOSURES PER I.B.C. SECTION 707. (C403.2 PROVISIONS APPLICABLE TO ALL MECHANICAL SYSTEMS) CONTRACTOR SHALL � � <br /> R R REFRIGERANT EC ELECTRICAL CONTRACTOR PROVIDE ALL MECHANICAL SYSTEMS AND EQUIPMENT, SERVING THE BUtLDING HEATWG, W � � � o � <br /> INSTALL COMBINATION SMOKE FtRE DAMPERS AT ALL PENETRATIONS OF FIRE � o �`� 4� � <br /> COOLING OR VENTILATING NEEDS, WHICH COMPLY WITH SECTIONS C403.2.1 THROUGH a � ��� � � <br /> �y � � a � o <br /> e O EER ENERGY EFFICIENCY RATING PARTITIONS, FIRE WALLS, FIRE BARRIERS AND SMOKE PARTITIONS PER I.B.C. C403.2.13. `i N � <br /> DUCT SECTION -SUPPLY CHAPTER 7. O N � <br /> � O EFF EFFICIENCY/EFFICIENT (C403.2.6 VENTILATION) CONTRACTOR SHALL PROVIDE VENTILATION, EITHER NATURAL OR LL g`� � �� � � <br /> DUCT SECTION - RETURN ALL FIRE DAMPERS SHALL BE DYNAMIC TYPE, U.L. 555 RATED.ALL CEILING MECHANICAL, IN ACCORDANCE WITH CHAPTER 4 OF THE INTERNATIONAL MECHANICAL 0 � � o_ '; <br /> FR FLOOR REGISTER RADIATION DAMPERS SHALL BE U.L. 555C RATED.ALL COMBINATION SMOKE CODE. WHERE MECHANICAL VENTILATION IS PROVIDED, THE SYSTEM SHALL BE � °' <br /> RECTANGULAR DUCT(INSIDE DIMENSION) FIRE DAMPERS SHALL BE U.L. 555S RATED. CONFIGURED TO PROVIDE NO GREATER THAN 150 PERCENT OF THE MINIMUM OUTDOOR W �' ° � <br /> GC GENERAL CONTRACTOR AIR REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE OR OTHER ��f � � <br /> ROUND DUCT INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER APPLICABLE CODE OR STANDARD, WHICHEVER IS GREATER. (n '� ¢ � <br /> I.B.C. REQUIREMENTS. PROVIDE ENGINEERED AND STAMPED DESIGN � �- " � <br /> HSPF HEATING SEASONAL PERFORMANCE FACTOR DRAWINGS IF REQUtRED BY IBC. CONTRACTOR TO CONTACT OR HIRE A � �"` ��� � °- <br /> SL SOUND LINED DUCT(INSIDE DIMENSION) (C403.2.6.3 OCCUPANCY SENSORS) CONTRACTOR SHALL PROVIDE OCCUPANCY SENSORS <br /> HWR HIGH WALL REGISTER STRUCTURAL ENGINEER TO DETERMINE BUILDING AND SYSTEM IMPORTANCE FOR CLASSROOMS, GYMS,AUDITORIUMS AND CONFERENCE ROOMS LARGER THAN 500 <br /> FLEXIBLE DUCT FACTORS. UTILIZE ISAT OR OTHER SEISMIC BRACING COMPANY. SQUARE FEET OF FLOOR AREA THAT WILL EITHER CLOSE OUTSIDE AIR DAMPERS OR <br /> HWG HIGH WALL GRILLE INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. TURN OFF SERVING EQUIPMENT WHEN THE SPACE IS UNOCCUPIED EXCEPT WHERE <br /> EQUIPPED WITH ANOTHER MEANS TO AUTOMATICALLY REDUCE OUTSIDE AIR INTAKE <br /> � SPIRAL DUCT BELOW DESIGN RATES WHEN SPACES ARE PARTIALLY OCCUPIED. <br /> I.E. INVERT ELEVATION MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT <br /> NECESSARILY REFLECT EVERY REQUIRED OFF-SET, FITTING OR ACCESSORY. <br /> s� � ADJUSTABLE AIR EXTRACTOR IPLV INTEGRATED PART LOAD VALUE (C403.2.8.1) CONTRACTOR SHALL PROVIDE DUCTS, SHAFTS AND PLENUMS CONVEYING <br /> COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING OUTSIDE AIR FROM THE EXTERIOR OF THE BUILDING TO THE MECHANICAL SYSTEM WHICH <br /> � TURNING VANE LWR LOW WALL REGISTER STRUCTURE AND ALL OTHER TRADES. MEET ALL AIR LEAKAGE AND BUILDING ENVELOPE INSULATION REQUIREMENTS OF � � <br /> �'� SECTION C402, PLUS BUILDING ENVELOPE VAPOR CONTROL REQUIREMENTS FROM THE <br /> � LWG LOW WALL GRILLE THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO INTERNATIONAL BUILDING CODE, EXTENDING CONTINUOUSLY FROM THE BUILDING � <br /> �� VD VOLUME DAMPER BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXTERIOR TO AN AUTOMATIC SHUTOFF DAMPER OR HEATING OR COOLING EQUIPMENT. � - <br /> MC MECHANICAL CONTRACTOR EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, FOR THE PURPOSES OF BUILDWG ENVELOPE WSULATION REQUIREMENTS, DUCT O <br /> —�M MD MOTORIZED DAMPER PIPES, UTILITIES AND BUILDING STRUCTURE: SURFACES SHALL MEET THE REQUIREMENTS FOR METAL FRAMED WALLS PER TABLE � <br /> BACKDRAFT DAMPER MECH. MECHANICAL VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. C402.1.2. <br /> —� BDD � <br /> OFCI OWNER FURNISHED, CONTRACTOR INSTALLED PROVIDE AND INSTALL A COMPLETE AND OPERATIONAL AUTOMATIC FIRE (C403.2.8.3.1 LOW-PRESSURE DUCT SYSTEMS) CONTRACTOR SHALL PROVIDE ALL � <br /> COMBINATION SMOKE/FIRE DAMPER LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND <br /> � SFD e SPRINKLER SYSTEM PER N.F.P.A. 13. PROVIDE ALL REQUIRED PIPING, HEADS, <br /> POC POINT OF CONNECTION VALVES, CONTROLS AND ACCESSORIES. PROVIDE ALL REQUIRED RETURN DUCTS OPERATING AT A STATIC PRESSURE LESS THAN OR EQUAL TO 2 INCHES :~� �1� <br /> --/ FD FIRE DAMPER C A L C U L A T I O N S. O B T A I N A N Y R E Q U I R E D P E R M I T S,A N D P A Y A L L R E Q U I R E D W A T E R G A U G E (W.G.) (5 0 0 P A)W I T H S E C U R E L Y F A S T E N E D A N D S E A L E D W I T H W E L D S, � _ <br /> TYP. TYPICAL FEES IN ORDER TO INSTALL A COMPLETE AND OPERATIONAL SYSTEM. GASKETS, MASTICS (ADHESIVES), MASTIGPLUS EMBEDDED-FABRIC SYSTEMS OR TAPES �1� <br /> � RAD CEILING RADIATION DAMPER INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. � W <br /> U.O.N. UNLESS OTHERWISE NOTED PROVIDE WATER HAMMER ARRESTOR ON FAST ACTION VALVES. PRESSURE CLASSIFICATIONS SPECIFIC TO THE DUCT SYSTEM SHALL BE CLEARLY INDICATED . . � <br /> DUCT SMOKE DETECTOR ON THE CONSTRUCTION DOCUMENTS IN ACCORDANCE WITH THE INTERNATIONAL <br /> o SD WC1 PLUMBING FIXTURE TAG ALL MECHANICAL EQUIPMENT LOCATED W CEILING CAVITIES THAT REQUIRE MECHANICA� CODE. N � <br /> ELECTRICAL CONNECTION SHALL HAVE AN 8-1/2"x11" LAMINATED SIGN � �f' - <br /> �r T'STAT THERMOSTAT PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: <br /> EF EQUIPMENT TAG (C4032.9 PIPING INSULATION) CONTRACTOR SHALL PROVIDE ALL PIPING SERVING AS PART � Q <br /> OO S SWITCH 1 THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V)AND OF A HEATING OR COOLING SYSTEM WITH THERMAL INSULATION IN ACCORDANCE WITH L <br /> 42° (460V AND ABOVE)". NO TRADE SHAL� BLOCK THIS SPACE EVEN IF SHOWN TABLE C403.2.9. � � <br /> � COS CARBON MONOXIDE SENSOR � ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. 1 <br /> FLAG NOTE (C403.2.9.1 PROTECTION OF PIPING INSULATION) CONTRACTOR SHALL PROTECT ALL U � <br /> MAJOR APPLICABLE CODES: PIPING INSULATION EXPOSED TO WEATHER FROM DAMAGE, INCLUDING THAT DUE TO (� � <br /> AFF ABOVE FINISHED FLOOR CONNECTION (NECK) SIZE SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE AND WIND, AND SHALL PROVIDE <br /> 2015 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. � � <br /> ARCH. ARCHITECT/ARCHITECTURAL 10"� CDL TYPE (CEILING DIFF. LAY-IN) 2015 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENT ADHESIVES TAPE SHALL NOT BE PERMITTED. �"� <br /> 300 CFM 2015 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS .� � <br /> CDS CEILING DIFFUSER-SURFACE MOUNTED FLOW RATE (CUBIC FEET PER MINUTE) (C403.2.10 MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS ' <br /> 2015 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS ) � � <br /> 2015 INTERNATIONAL FUEL GAS CODE WITH WASHINGTON STATE AMENDMENTS MECHANICAL SYSTEMS SHALL BE COMMISSIONED AND COMPLETED IN ACCORDANCE WITH <br /> CDL CEILING DIFFUSER-LAY IN 3° (125) FIXTURE UNITS or BTUH SECTION C408. � � <br /> � 2015 WASHINGTON STATE ENERGY CODE � <br /> CGS CEILING GRILLE-SURFACE MOUNTED PIPE SIZE (C403.2.11.3 FAN EFFICIENCY) CONTRACTOR SHALL PROVIDE FANS WITH A FAN EFFICIENCY � <br /> GRADE(FEG) OF 67 OR HIGHER PER AMCA 205.THE TOTAL EFFICIENCY AT DESIGN CONDITIONS � � <br /> CGL CEILING GRILLE-LAY IN DETAIL NUMBER SHALL BE WITHIN 15 PERCENT OF THE MAXIMUM TOTAL EFFICIENCY. O y <br /> COP COEFFICIENT OF PERFORMANCE 1 SHEET ON WHICH DETAIL IS DRAWN D RAW I N G I N D EX (C403.2.14 ELECTRIC MOTOR EFFICIENCY) CONTRACTOR SHALL PROVIDE ALL ELECTRIC �, "�'�� � <br /> � � �— m�.o MOTORS, INCLUDING FRACTIONAL HP MOTORS WITH C405.8. � C� r O <br /> � X DEMOLISH SHEET DESCRIPTION � � � ■� <br /> E EXIST. EX SECTION INDICATOR 25-MP1.0 COVER SHEET � 0 � � <br /> � ISTING ITEMS <br /> SHEET ON WHICH SECTION IS DRAWN 25-MP1.1 SCHEDULES O � > <br /> 1 25-MP2.0 MECHANICAL DETAILS <br /> OO � C� CLEAN OUT M� o N � Q O � <br /> 25-M203 HVAC- FLOOR PLAN � _ <br /> W OR SAN SANITARY WASTE � 25-P203 PLUMBlNG- BELOW FLOOR PLAN � � � � <br /> V VENT PIPE � REVISION TAG J U �,_, , <br /> - -- - - -- - - -- - J � �, �C <br /> a� � � <br /> U > � <br /> FALL PROTECTION NOISE CALCS � � w � <br /> � � � <br /> NO NOISE CALCULATIONS PROVIDED. NO NEW i � � �/1 <br /> NO FALL PROTECTION REQUIRED BECAUSE NO EQUIPMENT IS BEING LOCATED ON EQUIPMENT PROVIDED TO THE EXTERIOR OF THE w� <br /> THE ROOF. BUILDING. � �L �---� <br /> a. � � -S <br /> � � � N <br /> � � c� � <br /> LAVATORY MIXING VALVE ELEVATIONS � � �' � � <br /> NO ELEVATIONS ELEVATIONS PROVIDED. NO NEW � .� � N <br /> HOT WATER DELIVERED FROM PUBLIC-USE LAVATORIES SHALL BE LIMITED TO A EQUIPMENT PROVIDED TO THE EXTERIOR OF THE � � N N <br /> MAXIMUM TEMPERATURE OF 120°F BY A DEVICE THAT CONFORMS TO ASSE 1070 OR BUILDING. <br /> CSA B125.3 THE WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED A <br /> CONTROL FRO MEETING THIS PROVISION. <br /> A LAVATORY SHALL BE DEFINED AS A SINK USED PRIMARILY FOR HAND WASHING Job No: 1662 Date: Apr 28 2017 <br /> THAT IS ADJACENT TO WATER CLOSET(S)/URINAL(S). File No: 1662 Wiqqums Renovation.rvt <br /> ALL LAVATORIES SHALL BE CONSIDERED PUBLIC USE EXCEPT FOR THE <br /> Drawn By: ADD <br /> FOLLOWING <br /> Checked By: RP <br /> Issued for: Permit Set <br /> • LAVATORIES IN RESIDENCES AND APARTMENTS <br /> � • LAVATORIES IN HOTEL ROOMS <br /> • LAVATORIES IN PRIVATE HOSPITAL ROOMS <br /> COVER SHEET <br /> — <br /> . <br />