oF V r 7f ~ <br /> �' ��,�� �„� <br /> � W <br /> .� � <br /> h <br /> ���I19�2���� y N . <br /> .�,� v � <br /> SYMBOL LIST GENERAL NOTES 2015 WASHINGTON STATE ENERGY CODE NOTES � °iC � � <br /> � � <br /> � � � � <br /> � o _ a � � <br /> � <br /> SYMBOL ABBV. DESCRIPTION SYMBOL ABBV. DESCRIPTION PROTECT ALL DUCT OPENINGS OF FIRE RATED ASSEMBLIES PER I.B.C. 716. NOTE: ITEMS W (PARENTHESIS) REFERENCE CODE SECTIONS FROM THE 2015 ai a. o �Y m � <br /> WASHINGTON STATE ENERGY CODE. � � <br /> H � �, � <br /> C C CONDENSATE ELECT. ELECTRICAL INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF SHAFT � � � � � ��� � � <br /> ENCLOSURES PER I.B.C. SECTION 707. (C403.2 PROVISIONS APPLICABLE TO ALL MECHANICAL SYSTEMS) CONTRACTOR SHALL �/ L cn 'L f- ��� ¢ � <br /> PROVIDE ALL MECHANICAL SYSTEMS AND EQUIPMENT, SERVING THE BUILDING HEATING, W � �° w �; @ � <br /> , R R REFRIGERANT EC ELECTRICAL CONTRACTOR -a � -� ,�: � � <br /> INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF FIRE COOLING OR VENTILATWG NEEDS, WHICH COMPLY WITH SECTIONS C403.2.1 THROUGH � � � � � �� � � <br /> PARTITIONS, FIRE WALLS, FIRE BARRIERS AND SMOKE PARTITIONS PER I.B.C. C403.2.13. a <br /> e O DUCT SECTION -SUPPLY O - N � <br /> EER ENERGY EFFICIENCY RATING � O � <br /> CHAPTER 7. §� � o <br /> EFF EFFICIENCY/EFFICIENT (C403.2.6 VENTILATION) CONTRACTOR SHALL PROVIDE VENTILATION, EITHER NATURAL OR � Y � •.�:-, J M <br /> a O DUCT SECTION - RETURN ALL FIRE DAMPERS SHALL BE DYNAMIC TYPE, U.L. 555 RATED.ALL CEILWG MECHANICAL, IN ACCORDANCE WITH CHAPTER 4 OF THE WTERNATIONAL MECHANICAL � a �- <br /> FR FLOOR REGISTER RADIATION DAMPERS SHALL BE U.L. 555C RATED.ALL COMBINATION SMOKE CODE. WHERE MECHANICAL VENTILATION IS PROVIDED, THE SYSTEM SHALL BE W .� M <br /> RECTANGULAR DUCT(INSIDE DIMENSION) FIRE DAMPERS SHALL BE U.L. 555S RATED. CONFIGURED TO PROVIDE NO GREATER THAN 150 PERCENT OF THE MINIMUM OUTDOOR = ��� � � <br /> GC GENERAL CONTRACTOR AIR REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE OR OTHER ''� '� � `� <br /> INSTALL SEISMIC BRACING FORALL DUCTWORK, EQUIPMENTAND PIPWG PER � s�+ � � <br /> ROUND DUCT APPLICABLE CODE OR STANDARD, WHICHEVER IS GREATER. <br /> HSPF HEATING SEASONA� PERFORMANCE FACTOR I.B.C:REQUIREMENTS. PROVIDE ENGINEERED AND STAMPED DESIGN � <br /> DRAWINGS IF REQUIRED BY IBC. CONTRACTOR TO CONTACT OR HIRE A ~ � <br /> ----- --- - - SOUND LINED DUCT(INSIDE DIMENSION) � �; � � � <br /> (C4032.6.3 OCCUPANCY SENSORS) CONTRACTOR SHALL PROVIDE OCCUPANCY SENSORS <br /> _______ SL HWR HIGH WALL REGISTER STRUCTURAL ENGINEER TO DETERMINE BUILDING AND SYSTEM IMPORTANCE FOR CLASSROOMS, GYMS,AUDITORIUMS AND CONFERENCE ROOMS LARGER THAN 500 <br /> FLEXIBLE DUCT FACTORS. UTILIZE ISAT OR OTHER SEISMIC BRACING COMPANY. SQUARE FEET OF FLOOR AREA THAT WILL EITHER CLOSE OUTSIDE AIR DAMPERS OR <br /> HWG HIGH WALL GRILLE INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. TURN OFF SERVING EQUIPMENT WHEN THE SPACE IS UNOCCUPIED EXCEPT WHERE <br /> � EQUIPPED WITH ANOTHER MEANS TO AUTOMATICALLY REDUCE OUTSIDE AIR INTAKE <br /> SPIRAL DUCT I.E. INVERT ELEVATION MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE,AND DO NOT BELOW DESIGN RATES WHEN SPACES ARE PARTIALLY OCCUPIED. <br /> NECESSARILY REFLECT EVERY REQUIRED OFF-SET, FITTING OR ACCESSORY. <br /> ADJUSTABLE AIR EXTRACTOR IPLV INTEGRATED PART LOAD VALUE (C403.2.8.1) CONTRACTOR SHALL PROVIDE DUCTS, SHAFTS AND PLENUMS CONVEYING <br /> �s� COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING OUTSIDE AIR FROM THE EXTERIOR OF THE BUILDING TO THE MECHANICAL SYSTEM WHICH <br /> � TURNING VANE LWR LOW WALL REGISTER STRUCTURE AND ALL OTHER TRADES. MEET ALL AIR LEAKAGE AND BUILDING ENVELOPE INSULATION REQUIREMENTS OF CI� - <br /> �1'�, I SECTION C402, PLUS BUILDING ENVELOPE VAPOR CONTROL REQUIREMENTS FROM THE <br /> L I ' I THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO INTERNATIONAL BUILDING CODE, EXTENDING CONTINUOUSLY FROM THE BUILDING � <br /> VOLUME DAMPER LWG LOW WALL GRILLE BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY <br /> �� VD EXTERIOR TO AN AUTOMATIC SHUTOFF DAMPER OR HEATWG OR COOLWG EQUIPMENT. � <br /> MC MECHANICAL CONTRACTOR EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, FOR THE PURPOSES OF BUILDING ENVELOPE INSULATION REQUIREMENTS, DUCT Q <br /> —�]M MD MOTORIZED DAMPER PIPES, UTILITIES AND BUILDING STRUCTURE. SURFACES SHALL MEET THE REQUIREMENTS FOR METAL FRAMED WALLS PER TABLE � <br /> MECH. MECHANICAL C402.1.2. <br /> BACKDRAFT DAMPER VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. � <br /> —� BDD � <br /> OFCI OWNER FURNISHED, CONTRACTOR INSTALLED PROVIDE AND INSTALL A COMPLETE AND OPERATIONAL AUTOMATIC FIRE (C403.2.8.3.1 LOW-PRESSURE DUCT SYSTEMS) CONTRACTOR SHALL PROVIDE ALL <br /> _♦ COMBINATION SMOKE/FIRE DAMPER LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND <br /> SFD e SPRINKLER SYSTEM PER N.F.P.A. 13. PROVIDE ALL REQUIRED PIPING, HEADS, � <br /> POC POINT OF CONNECTION VALVES, CONTROLS AND ACCESSORIES. PROVIDE ALL REQUIRED RETURN DUCTS OPERATING AT A STATIC PRESSURE LESS THAN OR EQUAL TO 2 INCHES }� .�i <br /> —� FD FIRE DAMPER CALCULATIONS. OBTAIN ANY REQUIRED PERMITS, AND PAY ALL REQUIRED WATER GAUGE (W.G.) (500 PA) WITH SECURELY FASTENED AND SEALED WITH WELDS, � � <br /> TYP. TYPICAL FEES IN ORDER TO INSTALL A COMPLETE AND OPERATIONAL SYSTEM. GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC SYSTEMS OR TAPES � <br /> . �p CEILING RADIATION DAMPER INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. � <br /> U.O.N. UNLESS OTHERWISE NOTED PROVIDE WATER HAMMER ARRESTOR ON FAST ACTION VALVES. PRESSURE CLASSIFICATIONS SPECIFIC TO THE DUCT SYSTEM SHALL BE CLEARLY WDICATED � � � <br /> DUCT SMOKE DETECTOR ON THE CONSTRUCTION DOCUMENTS IN ACCORDANCE WITH THE WTERNATIONAL <br /> o SD WC1 PLUMBING FIXTURE TAG ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE MECHANICAL CODE. N � <br /> ELECTRICAL CONNECTION SHALL HAVE AN 8-112"x11" LAMINATED SIGN � � <br /> �r T'STAT THERMOSTAT EF PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: (C403.2.9 PIPING INSULATION) CONTRACTOR SHALL PROVIDE ALL PIPING SERVING AS PART O <br /> � EQUIPMENT TAG "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V)AND OF A HEATING OR COOLING SYSTEM WITH THERMAL INSULATION IN ACCORDANCE WITH � L <br /> Os S SWITCH 42" (460V AND ABOVE)". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN TABLE C403.2.9. � � <br /> ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. � <br /> c� COS CARBON MONOXIDE SENSOR � FLAG NOTE (C403.2.9.1 PROTECTION OF PIPING INSULATION) CONTRACTOR SHALL PROTECT ALL (.,� <br /> MAJOR APPLICABLE CODES: PIPING INSULATION EXPOSED TO WEATHER FROM DAMAGE, INCLUDING THAT DUE TO (� � <br /> AFF ABOVE FINISHED FLOOR CONNECTION (NECK) SIZE SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE AND WIND, AND SHALL PROVIDE <br /> 2015 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. � � ' <br /> ARCH. ARCHITECT/ARCHITECTURAL 10"� CDL TYPE (CEILING DIFF. LAY-IN) 2015 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS ADHESIVES TAPE SHALL NOT BE PERMITTED. � �� <br /> 300 CFM 2015 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS � <br /> CDS CEILING DIFFUSER-SURFACE MOUNTED FLOW RATE (CUBIC FEET PER MINUTE) (C403.2.10 MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS) rY1 � _ <br /> 2015 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS MECHANICAL SYSTEMS SHALL BE COMMISSIONED AND COMPLETED IN ACCORDANCE WITH �-�-� <br /> CDL CEILING DIFFUSER-LAY IN f-3° (125) FIXTURE UNITS or BTUH 2O15 INTERNATIONAL FUEL GAS CODE WITH WASHWGTON STATE AMENDMENTS SECTION C408. � � <br /> 2015 WASHINGTON STATE ENERGY CODE � <br /> CGS CEILING GRILLE-SURFACE MOUNTED PIPE SIZE (C403.2.11.3 FAN EFFICIENCY) CONTRACTOR SHALL PROVIDE FANS WITH A FAN EFFICIENCY C/� <br /> GRADE (FEG) OF 67 OR HIGHER PER AMCA 205. THE TOTAL EFFICIENCY AT DESIGN CONDITIONS � � <br /> CGL CEILING GRILLE-LAY IN DETAIL NUMBER SHALL BE WITHIN 15 PERCENT OF THE MAXIMUM TOTAL EFFICIENCY. O y <br /> COP COEFFICIENT OF PERFORMANCE 1 SHEET ON WHICH DETAIL IS DRAWN D RAW I N G I N D EX (C403.2.14 ELECTRIC MOTOR EFFICIENCY) CONTRACTOR SHALL PROVIDE ALL ELECTRIC � �� _ <br /> M�.o MOTORS, INCLUDING FRACTIONAL HP MOTORS WITH C405.8. � CCS � O <br /> . � � � ■� <br /> X DEMOLISH SHEET DESCRIPTION <br /> SECTION INDICATOR 27-MP1.0 COVER SNEET r O � � ' <br /> E, EXIST. EXISTING ITEMS � <br /> SHEET ON WHICH SECTION IS DRAWN 27-MP1.1 SCHEDULES N ^♦ � > <br /> 1 W Q 0 <br /> � 27-MP2.0 MECHANICAL DETAILS <br /> OQ CO CLEAN OUT M1.0 � �/ - <br /> 27-M201 HVAC- FLOOR PLAN - BUILDING TYPES 1 &4 � � <br /> W OR SAN SANITARY WASTE 27-P201 PLUMBING- BELOW FLOOR- BUILDING TYPES 1 &4 �- � � <br /> J U �'' <br /> � REVISION TAG � �, �1/ <br /> V VENT PIPE � � Q� w� <br /> _ �— �r <br /> � � j � <br /> NOISE CALCS � � w i <br /> FALL PROTECTION � L � �..� <br /> NO NOISE CALCULATIONS PROVIDED. NO NEW � � � � • <br /> NO FALL PROTECTION REQUIRED BECAUSE NO EQUIPMENT IS BEING LOCATED ON EQUIPMENT PROVIDED TO THE EXTERIOR OF THE L � � <br /> THE ROOF. BUILDING. (� <br /> � � � -�-� _ <br /> � Ncn .�.� <br /> � � N � <br /> LAVATORY MIXING VALVE ELEVATIONS � � � 1�. <br /> NO ELEVATIONS ELEVATIONS PROVIDED. NO NEW � -� O � <br /> HOT WATER DELIVERED FROM PUBLIC-USE LAVATORIES SHALL BE LIMITED TO A EQUIPMENT PROVIDED TO THE EXTERIOR OF THE � <br /> MAXIMUM TEMPERATURE OF 120°F BY A DEVICE THAT CONFORMS TO ASSE 1070 OR BUILDING. � N N <br /> CSA B125.3 THE WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED A <br /> CONTROL FRO MEETING THIS PROVISION. <br /> A LAVATORY SHALL BE DEFINED AS A SINK USED PRIMARILY FOR HAND WASHING Job No: 1662 Date: Apr 28 2017 <br /> THAT IS ADJACENT TO WATER CLOSET(S)/URINAL(S). File No: 1662 Wiggums Renovation.rvt <br /> Drawn Bv: ADD - <br /> ALL LAVATORIES SHALL BE CONSIDERED PUBLIC USE EXCEPT FOR THE Checked By: RP <br /> FOLLOWING: ' <br /> Issued for: Permit Set <br /> • LAVATORIES IN RESIDENCES AND APARTMENTS <br /> • LAVATORIES IN HOTEL ROOMS <br /> • LAVATORIES IN PRIVATE HOSPITAL ROOMS <br /> COVER SHEET - <br /> - <br /> . <br />