My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2731 12TH ST 2017 Plans 2022-12-12
>
Address Records
>
12TH ST
>
2731
>
Plans
>
2731 12TH ST 2017 Plans 2022-12-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2022 12:02:59 PM
Creation date
1/10/2019 8:18:10 AM
Metadata
Fields
Template:
Address Document
Street Name
12TH ST
Street Number
2731
Permit
B1705-052
X1706-017
Year
2017
Notes
INTERIOR AND EXTERIOR RENOVATIONS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
oF V �j ~ <br /> �� ���f� V <br /> W <br /> � � <br /> ���'(iI19SP������ i N <br /> ���� v � <br /> SYMBOL LIST GENERAL NOTES °C � � � � <br /> 2015 WASHINGTON STATE ENERGY CODE NOTES � � � � <br /> . . � C , �y� (6 U <br /> SYMBOL ABBV. DESCRIPTION � � °O � � � y � �' <br /> SYMBOL ABBV. DESCRIPTION PROTECT ALL DUCT OPENINGS OF FIRE RATED ASSEMBLIES PER I.B.C. 716. NOTE: ITEMS IN (PARENTHESIS) REFERENCE CODE SECTIONS FROM THE 2015 � a�i � o m � � <br /> WASHINGTON STATE ENERGY CODE: � � •� o o a� � <br /> C C CONDENSATE ELECT. ELECTRICAL INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF SHAFT � � � � � �. � � <br /> ENCLOSURES PER I.B.C. SECTION 707. (C403.2 PROVISIONS APPLICABLE TO ALL MECHANICAL SYSTEMS) CONTRACTOR SHALL �/ �' �n 'L � � a' � <br /> R R REFRIGERANT EC ELECTRICAL CONTRACTOR PROVIDE ALL MECHANICAL SYSTEMS AND EQUIPMENT, SERVING THE BUILDING HEATING, �,�„� � � w ��� a � <br /> WSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF FIRE COOLING OR VENTILATING NEEDS, WHICH COMPLY WITH SECTIONS C403.2.1 THROUGH � � o �� � <br /> DUCT SECTION- SUPPLY EER ENERGY EFFICIENCY RATING PARTITIONS, FIRE WALLS, FIRE BARRIERS AND SMOKE PARTITIONS PER I.B.C. C403.2.13. � � � a � o <br /> e O CHAPTER 7. � - - �" °° <br /> EFF EFFICIENCY/EFFICIENT (C403.2.6 VENTILATION) CONTRACTOR SHALL PROVIDE VENTILATION, EITHER NATURAL OR O � p � �� `�� c_, � <br /> 0 O DUCT SECTION - RETURN ALL FIRE DAMPERS SHALL BE DYNAMIC TYPE, U.L 555 RATED.ALL CEiLING MECHANICAL, IN ACCORDANCE WITH CHAPTER 4 OF THE INTERNATIONAL MECHANICAL � � <br /> FR FLOOR REGISTER RADIATION DAMPERS SHALL BE U.L. 555C RATED.ALL COMBINATION SMOKE CODE. WHERE MECHANICAL VENTILATION IS PROVIDED, THE SYSTEM SHALL BE � � M <br /> RECTANGULAR DUCT(INSIDE DIMENSION) FIRE DAMPERS SHALL BE U.L. 555S RATED. CONFIGURED TO PROVIDE NO GREATER THAN 150 PERCENT OF THE MINIMUM OUTDOOR � � � <br /> GC GENERAL CONTRACTOR INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER AIR REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE OR OTHER � ��� � � <br /> � ROUND DUCT APPLICABLE CODE OR STANDARD, WHICHEVER IS GREATER. � <br /> HSPF HEATING SEASONAL PERFORMANCE FACTOR I.B.C. REQUIREMENTS. PROVIDE ENGINEERED AND STAMPED DESIGN � � � � � <br /> - -- - --- SOUND LINED DUCT(INSIDE DIMENSION) DRAWWGS IF REQUIRED BY IBC. CONTRACTOR TO CONTACT OR HIRE A (C4032.6.3 OCCUPANCY SENSORS) CONTRACTOR SHALL PROVIDE OCCUPANCY SENSORS A �= f n � � ° <br /> _ ___ ______ SL STRUCTURAL ENGINEER TO DETERMINE BUILDING AND SYSTEM IMPORTANCE F O R C L A S S R O O M S, G Y M S, A U D I T O R I U M S A N D C O N F E R E N C E R O O M S L A R G E R T H A N 5 0 0 <br /> H W R H I G H W A L L R E G I S T E R FACTORS. UTILIZE ISAT OR OTHER SEISMIC BRACING COMPANY. SQUARE FEET OF FLOOR AREA THAT WILL EITHER CLOSE OUTSIDE AIR DAMPERS OR <br /> FLEXIBLE DUCT <br /> HWG HIGH WALL GRILLE INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. TURN OFF SERVING EQUIPMENT WHEN THE SPACE IS UNOCCUPIED EXCEPT WHERE <br /> EQUIPPED WITH ANOTHER MEANS TO AUTOMATICALLY REDUCE OUTSIDE AIR INTAKE <br /> � SPIRAL DUCT BELOW DESIGN RATES WHEN SPACES ARE PARTIALLY OCCUPIED. <br /> I.E. INVERT ELEVATION MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE,AND DO NOT <br /> � NECESSARILY REFLECT EVERY REQUIRED OFF-SET, FITTING OR ACCESSORY. <br /> �— ADJUSTABLE AIR EXTRACTOR IPLV INTEGRATED PART LOAD VALUE (C403.2.8.1) CONTRACTOR SHALL PROVIDE DUCTS, SHAFTS AND PLENUMS CONVEYING <br /> COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING OUTSIDE AIR FROM THE EXTERIOR OF THE BUILDING TO THE MECHANICAL SYSTEM WHICH <br /> � TURNING VANE LWR LOW WALL REGISTER STRUCTURE AND ALL OTHER TRADES. MEET ALL AIR LEAKAGE AND BUILDING ENVELOPE INSULATION REQUIREMENTS OF U� <br /> I I�' I SECTION C402, PLUS BUILDING ENVELOPE VAPOR CONTROL REQUIREMENTS FROM THE <br /> LWG LOW WALL GRILLE THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO INTERNATIONAL BUILDING CODE, EXTENDING CONTINUOUSLY FROM THE BUILDING � <br /> , �� VD VOLUME DAMPER BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXTERIOR TO AN AUTOMATIC SHUTOFF DAMPER OR HEATING OR COOLING EQUIPMENT. � <br /> MC MECHANICAL CONTRACTOR EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTWG SYSTEMS, DUCTS, FOR THE PURPOSES OF BUILDING ENVELOPE INSULATION REQUIREMENTS, DUCT Q <br /> MOTORIZED DAMPER PIPES, UTILITIES AND BUILDING STRUCTURE. � - <br /> —� MD SURFACES SHALL MEET THE REQUIREMENTS FOR METAL FRAMED WALLS PER TABLE <br /> MECH. MECHANICAL C402.1.2. <br /> � BDD BACKDRAFT DAMPER VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. � <br /> OFCI OWNER FURNISHED, CONTRACTOR INSTALLED PROVIDE AND INSTALL A COMPLETE AND OPERATIONAL AUTOMATIC FIRE (C403.2.8.3.1 LOW-PRESSURE DUCT SYSTEMS) CONTRACTOR SHALL PROVIDE ALL � <br /> COMBINATION SMOKE/FIRE DAMPER <br /> � SFD e SPRINKLER SYSTEM PER N.F.P.A. 13. PROVIDE ALL REQUIRED PIPING, HEADS, LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND <br /> POC POINT OF CONNECTION VALVES, CONTROLS AND ACCESSORIES. PROVIDE ALL REQUIRED RETURN DUCTS OPERATING AT A STATIC PRESSURE LESS THAN OR EQUAL TO 2 INCHES }� y <br /> � FD FIRE DAMPER CALCULATIONS. OBTAIN ANY REQUIRED PERMITS, AND PAY ALL REQUIRED WATER GAUGE (W.G.) (500 PA)WITH SECURELY FASTENED AND SEALED WITH WELDS, � � <br /> TYP. TYPICAL FEES IN ORDER TO INSTALL A COMPLETE AND OPERATIONAL SYSTEM. GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC SYSTEMS OR TAPES �1� <br /> . �p CEILING RADIATION DAMPER INSTA�LED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. � W <br /> U.O.N. UNLESS OTHERWISE NOTED PROVIDE WATER HAMMER ARRESTOR ON FAST ACTION VALVES. PRESSURE CLASSIFICATIONS SPECIFIC TO THE DUCT SYSTEM SHALL BE CLEARLY INDICATED � <br /> DUCT SMOKE DETECTOR O ON THE CONSTRUCTION DOCUMENTS IN ACCORDANCE WITH THE INTERNATIONAL ^� �, <br /> o SD WC� PLUMBING FIXTURE TAG ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE MECHANICAL CODE. ` v � <br /> ELECTRICAL CONNECTION SHALL HAVE AN 8-1/2"x11" LAMINATED SIGN > <br /> �r T'STAT THERMOSTAT � O <br /> EF PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: (C403.2.9 PIPING INSULATION) CONTRACTOR SHALL PROVIDE ALL PIPING SERVING AS PART <br /> � EQUIPMENT TAG "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V)AND OF A HEATING OR COOLING SYSTEM WITH THERMAL INSULATION IN ACCORDANCE WITH � L <br /> O S SWITCH 42° (460V AND ABOVE)". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN TABLE C403.2.9. � <br /> c0 COS CARBON MONOXIDE SENSOR � FLAG NOTE ON THE DRAWINGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. �C <br /> (C403:2.9.1 PROTECTION OF PIPING INSULATION) CONTRACTOR SHALL PROTECT ALL V � <br /> AFF ABOVE FINISHED FLOOR MAJOR APPLICABLE CODES: PIPING INSULATION EXPOSED TO WEATHER FROM DAMAGE, INCLUDING THAT DUE TO (� � <br /> CONNECTION (NECK) SIZE SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE AND WIND, AND SHALL PROVIDE ^ <br /> 2015 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. LL <br /> ARCH. ARCHITECT/ARCHITECTURAL 300 C M TYPE (CEILING DIFF. LAY-IN) 2015 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS ADHESIVES TAPE SHALL NOT BE PERMITTED. � �••� <br /> 2 0 1 5 U N I F O R M P L U M B I N G C O D E W I T H W A S H I N G T O N S T A T E A M E N D M E N T S <br /> C D S CEILING DIFFUSER-SURFACE MOUNTED FLOW RATE (CUBIC FEET PER MINUTE) 2015 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS (C403.2.10 MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS) ry� � <br /> MECHANICAL SYSTEMS SHALL BE COMMISSIONED AND COMPLETED IN ACCORDANCE WITH � ' ' <br /> C D L CEILING DIFFUSER-LAY IN �-3" (125) FIXTURE UNITS or BTUH 2 O 1 5 I N T E R N A T I O N A L F U E L G A S C O D E W I T H W A S H I N G T O N S T A T E A M E N D M E N T S SECTION C408. � � � <br /> 2015 WASHINGTON STATE ENERGY CODE � <br /> ' CGS CEILING GRILLE-SURFACE MOUNTED PIPE SIZE (C403.2.11.3 FAN EFFICIENCY) CONTRACTOR SHALL PROVIDE FANS WITH A FAN EFFICIENCY (/� <br /> GRADE (FEG) OF 67 OR HIGHER PER AMCA 205. THE TOTAL EFFICIENCY AT DESIGN CONDITIONS � � � <br /> CGL CEILING GRILLE-LAY IN DETAIL NUMBER SHALL BE WITHIN 15 PERCENT OF THE MAXIMUM TOTAL EFFICIENCY. O � <br /> COP COEFFICIENT OF PERFORMANCE 1 SHEET ON WHICH DETAIL IS DRAWN D RAWI N G I N D EX �, � <br /> (C403.2.14 ELECTRIC MOTOR EFFICIENCY) CONTRACTOR SHALL PROVIDE ALL ELECTRIC -F-+ <br /> ;� ;� M�.o MOTORS, INCLUDING FRACTIONAL HP MOTORS WITH C405.8. � (� r O <br /> X DEMOLISH <br /> SECTION INDICATOR SHEET DESCRIPTION � � N �� <br /> 23-MP1.0 COVER SHEET � � � � <br /> E, EXIST. EXISTING ITEMS <br /> SHEET ON WHICH SECTION IS DRAWN 23-MP1.1 SCHEDULES N � � � <br /> O 1 23-MP2.0 MECHANICAL DETAILS � � O <br /> � CO CLEAN OUT M�.o , <br /> 23-M202 HVAC- FLOOR PLAN � � <br /> W OR SAN SANITARY WASTE 23-P202 PLUMBING- BELOW FLOOR PLA�I � <br /> J U �; CJ� <br /> � REVISION TAG � � � <br /> - - - - - -- - -- -- V VENTPIPE � � � <br /> �� L ♦J <br /> � � j � <br /> NOISE CALCS � � W i <br /> FALL PROTECTION NO NOISE CALCULATIONS PROVIDED. NO NEW � � � }+ <br /> NO FALL PROTECTION REQUIRED BECAUSE NO EQUIPMENT IS BEING LOCATED ON EQUIPMENT PROVIDED TO THE EXTERIOR OF THE � � � � <br /> THE ROOF. BUILDING. � +-+ <br /> � � � ��.+ <br /> � � .� N . <br /> � � CV r <br /> LAVATORY MIXING VALVE ELEVATIONS � � � M <br /> NO ELEVATIONS ELEVATIONS PROVIDED. NO NEW � .� � N <br /> HOT WATER DELIVERED FROM PUBLIGUSE LAVATORIES SHALL BE LIMITED TO A EQUIPMENT PROVIDED TO THE EXTERIOR OF THE — � �• <br /> MAXIMUM TEMPERATURE OF 120°F BY A DEVICE THAT CONFORMS TO ASSE 1070 OR BUILDING. � � (V N <br /> CSA B125.3 THE WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED A <br /> CONTROL FRO MEETING THIS PROVISION. <br /> A LAVATORY SHALL BE DEFINED AS A SINK USED PRIMARILY FOR HAND WASHING Job No: 1662 Date: Apr 28 2017 <br /> THAT IS ADJACENT TO WATER CLOSET(S)/URINAL(S). File No: 1662 Wiqgums Renovation.rvt <br /> ALL LAVATORIES SHALL BE CONSIDERED PUBLIC USE EXCEPT FOR THE <br /> Drawn By: ADD <br /> Checked BY: RP <br /> FOLLOWING: ' � <br /> Issuetl for. Permit Set <br /> ' • LAVATORIES IN RESIDENCES AND APARTMENTS <br /> • LAVATORIES IN HOTE� ROOMS - <br /> • LAVATORIES IN PRIVATE HOSPITAL ROOMS <br /> COVER SHEET . <br /> _ <br /> . <br />
The URL can be used to link to this page
Your browser does not support the video tag.