oF��r ~ . <br /> � I. ��� w <br /> H <br /> � � � , <br /> ��I19���� y N <br /> . . . � . s�� � t ' '� Q . <br /> V <br /> SYMBOL LIST GENERAL NOTES 2015 WASHINGTON STATE ENERGY CODE NOTES � � <br /> b � o <br /> � � Q � U <br /> B DESCRIPTION � � <br /> PROTECT ALL DUCT OPENINGS OF FIRE RATED ASSEMBLIES PER I.B.C. 716. NOTE: ITEMS W (PARENTHESIS) REFERENCE CODE SECTIONS FROM THE 2015 � o M ��+ �`. .�' �� <br /> SYMBOL A BV. SYMBOL ABBV. DESCRIPTION � � Q o m � <br /> WASHINGTON STATE ENERGY CODE. a� "o� a o � � <br /> C C CONDENSATE ELECT. ELECTRICAL INSTALL COMBINATION SMOKE FIRE DAMPERS ATALL PENETRATIONS OF SHAFT � � � � � � W q �� �._;..�� � � ' <br /> ENCLOSURES PER I.B.C. SECTION 707. (C403.2 PROVISIONS APPLICABLE TO ALL MECHANICAL SYSTEMS) CONTRACTOR SHALL � � •�? �i � ��`° � � <br /> REFRIGERANT EC ELECTRICAL CONTRACTOR PROVIDE ALL MECHANICAL SYSTEMS AND EQUIPMENT, SERVING THE BUILDING HEATING, W � � � '�� `° <br /> R R � ��-.:_ .� � <br /> INSTALL COMBINATION SMOKE FIRE DAMPERS AT ALL PENETRATIONS OF FIRE COOLWG OR VENTILATING NEEDS, WHICH COMPLY WITH SECTIONS C403.2.1 THROUGH a � � � � o <br /> EER ENERGY EFFICIENCY RATING PARTITIONS, FIRE WALLS, FIRE BARRIERS AND SMOKE PARTITIONS PER I.B.C. C403.2.13. � O N � <br /> B O DUCT SECTION - SUPPLYO , �• � <br /> CHAPTER 7. <br /> N M <br /> � � ti <br /> EFF EFFICIENCY/EFFICIENT (C403.2.6 VENTILATION) CONTRACTOR SHALL PROVIDE VENTILATION, EITHER NATURAL OR LL � '�°` � � � <br /> a O DUCT SECTION - RETURN ��� <br /> J M <br /> ALL FIRE DAMPERS SHALL BE DYNAMIC TYPE, U.L. 555 RATED.ALL CEILING MECHANICAL, IN ACCORDANCE WITH CNAPTER 4 OF THE INTERNATIONAL MECHANICAL � a `; <br /> FR FLOOR REGISTER RADIATION DAMPERS SHALL BE U.L 555C RATED.ALL COMBINATION SMOKE CODE. WHERE MECHANICAL VENTILATION IS PROVIDED, THE SYSTEM SHALL BE W �, '� � � <br /> RECTANGULAR DUCT(INSIDE DIMENSION) FIRE DAMPERS SHALL BE U.L. 555S RATED. CONFIGURED TO PROVIDE NO GREATER THAN 150 PERCENT OF THE MINIMUM OUTDOOR '� � <br /> GC GENERAL CONTRACTOR AIR REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE OR OTHER (_ . j� � �� � � <br /> ROUND DUCT INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER APPLICABLE CODE OR STANDARD, WHICHEVER IS GREATER. (n � � � <br /> HSPF HEATING SEASONAL PERFORMANCE FACTOR I.B.C. REQUIREMENTS. PROVIDE ENGINEERED AND STAMPED DESIGN — ��,��' � , � � � <br /> _____________________ DRAWINGS IF REQUIRED BY IBC. CONTRACTOR TO CONTACT OR HIRE A C403.2.6.3 OCCUPANCY SENSORS CONTRACTOR SHALL PROVIDE OCCUPANCY SENSORS <br /> SL SOUND LWED DUCT(INSIDE DIMENSION) � ) <br /> --------------------- HWR HIGH WALL REGISTER STRUCTURAL ENGINEER TO DETERMINE BUILDING AND SYSTEM IMPORTANCE FOR CLASSROOMS, GYMS, AUDITORIUMS AND CONFERENCE ROOMS LARGER THAN 500 � <br /> FLEXIBLE DUCT FACTORS. UTILIZE ISAT OR OTHER SEISMIC BRACING COMPANY. SQUARE FEET OF FLOOR AREA THAT WILL EITHER CLOSE OUTSIDE AIR DAMPERS OR <br /> HWG HIGH WALL GRILLE INSTALL ALL PIPING ON ROOM SIDE OF BUILDING INSULATION. TURN OFF SERVING EQUIPMENT WHEN THE SPACE IS UNOCCUPIED EXCEPT WHERE <br /> EQUIPPED WITH ANOTHER MEANS TO AUTOMATICALLY REDUCE OUTSIDE AIR INTAKE <br /> ' SPIRAL DUCT �.E. INVERT ELEVATION MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT BELOW DESIGN RATES WHEN SPACES ARE PARTIALLY OCCUPIED. <br /> NECESSARILY REFLECT EVERY REQUIRED OFF-SET, FITTING OR ACCESSORY. <br /> ADJUSTABLE A{R EXTRACTOR IPLV INTEGRATED PART LOAD VALUE (C403.2.8.1) CONTRACTOR SHALL PROVIDE DUCTS, SHAFTS AND PLENUMS CONVEYWG <br /> COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING OUTSIDE AIR FROM THE EXTERIOR OF THE BUILDING TO THE MECHANICAL SYSTEM WHICH � <br /> � TURNING VANE LWR LOW WALL REGISTER STRUCTURE AND ALL OTHER TRADES. MEET ALL AIR LEAKAGE AND BUILDING ENVELOPE INSULATION REQUIREMENTS OF <br /> '�, SECTION C402, PLUS BUILDWG ENVELOPE VAPOR CONTROL REQUIREMENTSfROM THE <br /> � LWG LOW WALL GRILLE THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO INTERNATIONAL BUILDING CODE, EXTENDING CONTINUOUSLY FROM THE BUILDING � <br /> �� VD VOLUME DAMPER BEGINNING WORK IN ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXTERIOR TO AN AUTOMATIC SHUTOFF DAMPER OR HEATING OR COOLING EQUIPMENT. � <br /> MC MECHANICAL CONTRAGTOR EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, FOR THE PURPOSES OF BUILDING ENVELOPE INSULATION REQUIREMENTS, DUCT O <br /> —� MD MOTORIZED DAMPER PIPES, UTILITIES AND BUILDWG STRUCTURE. SURFACES SHALL MEET THE REQUIREMENTS FOR METAL FRAMED WALLS PER TABLE � <br /> MECH. MECHANICAL C402.1.2. , <br /> –� BDD BACKDRAFT DAMPER VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. � <br /> OFCI OWNER FURNISHED, CONTRACTOR INSTALLED PROVIDE AND INSTALL A COMPLETE AND OPERATIONAL AUTOMATIC FIRE (C403.2.8.3.1 LOW-PRESSURE DUCT SYSTEMS) CONTRACTOR SHALL PROVIDE ALL � <br /> _♦ COMBINATION SMOKE/FIRE DAMPER LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND _ <br /> SFD e SPRINKLER SYSTEM PER N.F.P.A. 13. PROVIDE ALL REQUIRED PIPING, HEADS, V� <br /> POC POINT OF CONNECTION VALVES, CONTROLS AND ACCESSORIES. PROVIDE ALL REQUIRED RETURN DUCTS OPERATING AT A STATIC PRESSURE LESS THAN OR EQUAL TO 2 INCHES :'~� �1� <br /> —� FD FIRE DAMPER CALCULATIONS. OBTAIN ANY REQUIRED PERMITS, AND PAY ALL REQUIRED WATER GAUGE (W.G.) (500 PA)WITH SECURELY FASTENED AND SEALED WITH WELDS, � � <br /> TYP. TYPICAL FEES IN ORDER TO INSTALL A COMPLETE AND OPERATIONAL SYSTEM. GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABR�C SYSTEMS OR TAPES � � <br /> � RAD CEILING RADIATION DAMPER INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. � <br /> U.O.N. UNLESS OTHERWISE NOTED PROVIDE WATER HAMMER ARRESTOR ON FAST ACTION VALVES. PRESSURE CLASSIFICATIONS SPECIFIC TO THE DUCT SYSTEM SHALL BE CLEARLY INDICATED . . <br /> DUCT SMOKE DETECTOR ON THE CONSTRUCTION DOCUMENTS IN ACCORDANCE WITH THE INTERNATIONAL �1� <br /> o SD WC1 PLUMBING FIXTURE TAG ALL MECHANICAL EQUIPMENT LOCATED IN CEILING CAVITIES THAT REQUIRE MECHANICAL CODE. N W <br /> ELECTRICAL CONNECTION SHALL HAVE AN 8-1/2"x11" LAMINATED SIGN � � <br /> �r T'STAT THERMOSTAT EF PERMANENTLY MOUNTED ON THE ELECTRICAL ENCLOSURES THAT INDICATES: (C403.2.9 PIPING INSULATION) CONTRACTOR SHALL PROVIDE ALL PIPING SERVING AS PART <br /> s S SWITCH � EQUIPMENT TAG "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36" (LESS THAN 460V)AND OF A HEATING OR COOLING SYSTEM WITH THERMAL INSULATION IN ACCORDANCE WITH � O <br /> , � 42" (460V AND ABOVE)". NO TRADE SHALL BLOCK THIS SPACE EVEN IF SHOWN TABLE C403.2.9. � <br /> �c COS CARBON MONOXIDE SENSOR 1� ON THE DRAWWGS. INSTALL SIGN PRIOR TO INSTALLATION OF EQUIPMENT. � � <br /> � FLAG NOTE <br /> (C403.2.9.1 PROTECTION OF PIPING INSULATION) CONTRACTOR SHALL PROTECT ALL <br /> MAJOR APPLICABLE CODES: PIPING INSULATION EXPOSED TO WEATHER FROM DAMAGE, INCLUDING THAT DUE TO (a � <br /> AFF ABOVE FINISHED FLOOR CONNECTION (NECK) SIZE SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE AND WIND,AND SHALL PROVIDE <br /> 2015 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. � � � <br /> ARCH. ARCHITECT/ARCHITECTURAL 10"ra CDL TYPE (CEILING DIFF. LAY-IN) 2015 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENT ADHESNES TAPE SHALL NOT BE PERMITTED. � `� <br /> 300 CFM 2015 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS �� /� <br /> CDS CEILING DIFFUSER-SURFACE MOUNTED FLOW RATE (CUBIC FEET PER MINUTE) 2015 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS (C403.2.10 MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS) � V� <br /> 2015 INTERNATIONAL FUEL GAS CODE WITH WASHINGTON STATE AMENDMENTS MECHANICAL SYSTEMS SHALL BE COMMISSIONED AND COMPLETED IN ACCORDANCE WITH <br /> CDL CEILING DIFFUSER-LAY IN �3" (125) FIXTURE UNITS or BTUH 2O15 WASHINGTON STATE ENERGY CODE SECTION C408. 1 � <br /> CGS CEILING GRILLE-SURFACE MOUNTED PIPE SIZE (C403.2.11.3 FAN EFFICIENCY) CONTRACTOR SHALL PROVIDE FANS WITH A FAN EFFICIENCY � � <br /> GRADE (FEG) OF 67 OR HIGHER PER AMCA 205. THE TOTAL EFFICIENCY AT DESIGN CONDITIONS � � <br /> CGL CEILING GRILLE-LAY IN DETAIL NUMBER SHALL BE WITHIN 15 PERCENT OF THE MAXIMUM TOTAL EFFICIENCY. Q � <br /> COP COEFFICIENT OF PERFORMANCE 1 SHEET ON WHICH DETAIL IS DRAWN D RAWI N G i N D EX (G403.2.14 ELECTRIC MOTOR EFFICIENCY) CONTRACTOR SHALL PROVIDE ALL ELECTRIC � '�, � <br /> M�.o MOTORS, INCLUDING FRACTIONAL HP MOTORS WITH C405.8. r � � O <br /> � � .� <br /> X DEMOLISH SHEET DESCRIPTION " <br /> SECTION INDICATOR 11-MP1.0 COVER SHEET r– O QD � <br /> E, EXIST. EXISTING ITEMS � <br /> SHEET ON WHICH SECTION IS DRAWN 11-MP1.1 SCHEDULES N � � > <br /> 1 11-MP2.0 MECHANICAL DETAILS Q O <br /> OO � CD CLEAN OUT M�.o � �'�/ <br /> 11-M202 HVAC- FLOOR PLAN �"�� � � <br /> W OR SAN SANITARY WASTE 11-P202 PLUMBING - BELOW FLOOR PLAN � Q� � � <br /> � REVISION TAG � V � � <br /> - - --- - - - --- - V VENTPIPE � � � <br /> � � '�"� . <br /> U > � <br /> FALL PROTECTION NOISE CALCS � L w L <br /> NO NOISE CALCULATIONS PROVIDED. NO NEW � � � � <br /> NO FALL PROTECTION REQUIRED BECAUSE NO EQUIPMENT IS BEING LOCATED ON EQUIPMENT PROVIDED TO THE EXTERIOR OF THE L � � <br /> THE ROOF. BUILDING. <br /> � � � � <br /> � � � cv <br /> � � � r- <br /> LAVATORY MIXING VALVE ELEVATIONS � � � � <br /> NO ELEVATIONS ELEVATIONS PROVIDED. NO NEW � -- O � <br /> HOT WATER DELIVERED FROM PUBLIGUSE LAVATORIES SHALL BE LIMITED TO A EQUIPMENT PROVIDED TO THE EXTERIOR OF THE � � � <br /> MAXIMUM TEMPERATURE OF 120°F BY A DEVICE THAT CONFORMS TO ASSE 1070 OR BUILDING. N N <br /> CSA B125.3 THE WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED A <br /> CONTROL FRO MEETING THIS PROVISION. � <br /> A LAVATORY SHALL BE DEFINED AS A SINK USED PRIMARILY FOR HAND WASHING Job No: 1662 Date:Apr 28 2017 <br /> THAT IS ADJACENT TO WATER CLOSET(S)/URINAL(S). File No: 1662 Wigqums Renovation.rvt <br /> Drawn By: ADD <br /> ALL LAVATORIES SHALL BE CONSIDERED PUBLIC USE EXCEPT FOR THE Checked Bv: RP <br /> FOLLOWING: <br /> Issued for: Permit Set <br /> • LAVATORIES IN RESIDENCES AND APARTMENTS <br /> • LAVATORIES IN HOTEL ROOMS <br /> • LAVATORIES IN PRIVATE HOSPITAL ROOMS <br /> COVER SHEET <br /> _ <br /> . <br />