i i i i i
<br /> 3�'-2" VIF � �
<br /> �2�-2 �,4��+,_ 8�_��� 4'-4�� �2'-2 3/4�� y�� G E N E RAL M E D GAS N OT E S G E N E RAL N OT E S � z =
<br /> LAB HALLWAY I. THIS 15 A LEV�L 3 M�DIGAL �AGILITY AS DEFINED BY THE N�PA SEGTION 3.3.a2. I. PROTEGT ANY ITEMS TO REMAIN A6AIN5T DAMAGE DURIN6 GONSTRUGTION. � W
<br /> 110 111 "LE�lEL 3 MEDIGAL PIPED 6A5 AND 5Y5TEM5: SYSTEMS SERVING OGGUPANGIES WH�RE 2, pATGH AND REPAIR EXISTING G.W.B. THROUGHOUT A5 REQUIRED AND PREPARE SURFAGE ` °
<br /> �
<br /> ---- - ------- - - ------ ----- ____ INTERRUPTIONS O� THE PIPED MEDIGAL GA5 WOULD TERMINATE PROGEDUi�ES, BUT � F �� � �
<br /> -- - �OR N�W FINISH PER SGHEDUL�. �
<br /> ----"-- - --- - --- -- -" WOULD NOT PLAGE PATIENTS AT RISK O� MORBIDITY OR MORTALITY.° � '
<br /> 2. NITROUS OXIDE AND OXY6EN TANK STORAGE RODM MUST BE I-HOUR GONSTRUGTION 3. INSTALL NEW G.W.B. ON EXISTING BARE 5TUD5 THROUGHOUT, AND PREPARE SURFAGE �OR ;�� � ,
<br /> r _ _ � _ __ _-____ ____ NEW FIN15H PER SGHEDULE. ��� � �
<br /> KN-14 AND MEET Y�NTING REQUIREM�NTS �OR ALL GURRENT GODES AND R�GULATIONS. � " �
<br /> � � KN-O6 A KN-O6 4. f'ROVIDE AND INSTALL NEW PAINT, FLOORING AND BASE THROUGHOUT, UNO. ALL WALLS -
<br /> W/D A VERI�Y REQUIR�MFNTS WITH DENTAL �QUIPM�NT SPEGIALIST. ���� O `�
<br /> � � ' " ' I10 , 112 KN-14 3. PROVIDE NEGE55ARY SAGKING TO SEGURELY ATTAGH GA5 TANKS TO WA�LL. TO BE PAINTED. �� � ' '
<br /> L - - � - 5. REPAIR GONGRETE �LDOR 5UB5TRAT� A5 REQUIRED FOR NEW �INI5HE5. � �
<br /> r r I S O P 2 4. TANKS INGLUDE: � �
<br /> LAUNDRY � N� �� ��� � �.� ; r ��� 6. 5EE Iq/A6.01 FOR SAWGUT DETAIL WHERE REQUIRED. � ��� �
<br /> _ a
<br /> '- � A 8.0 1 ' � Q � 1 1 2 (2) T Y P E "G" N I T R O U S O X I D� T A N K S � 5 5 8 5 G� E A. „ �
<br /> 7. 5EE 4/A6.01 �OR TYPIGAL MOUNTING HEIGHTS.
<br /> + KN-10 _ _ __ ; � ,� I (2) TYPE ��G�� OXYGEN TANKS � 24q SGF EA. �
<br /> � STAFF ` /j ; 'T -- �`- � \ ; II - TOTAL 6A5: 3,228 5GF 8. PRIOR TO GOMPL�TION O� GONSTRUGTION, GLEAN ALL SUR�AGES, INGLUDING BUT NOT
<br /> m LOUNGE �� � ��� � / � �3`�'"`� � � � LIMIT�D TO, WINDOWS (INTERIOR AND EXTERIOR), STORE�RONTS, SWITGH AND OUTLET ■ �
<br /> �;' 109 �� � ���� ' �� �� � I ' a� PLATES, HVAG GRILLES AND GEILING GRID, RESTROOM �IXTURFS AND AGGE550RIE5. �
<br /> �`+ A8.01 _ _ � 'I � cr� RESTORE ANY O� TH� ABOVE TO GOOD WORKING GONDITION AS REQUIRED. � �■ � � �
<br /> '' ' q. WAT�R RE515TANT GWB TO BE USED AT ALL WET aREAS, NPIGAL. a
<br /> KN-13 A � ' ' �
<br /> i I 10.ALL OF�IGE �URNITURE AND 5ALE5 �LOOR �IXTURING BY OWNER.
<br /> 8'_� „2" '°p M E D I C A L G A S L E G E N D W -
<br /> 2 FLOOR PLAN KEYNOTES �
<br /> _ � - �� p� N20/02 (NITROUS OXIDE AND OXYGEN) GENTRAL SYSTEM:
<br /> A 15 0 __ ' P�� THIS 5Y5TEM REQUIRES I/2" D.D. GOPPER TUBING OXYGEN AND 3/8" O.D. GOPPER ��
<br /> ���r ` °' `` 108 � ' ` , A8.01 - - c� KN-OI ADA TRANSAGTION GOUNTER AT 36 A�F P�R IGG/AN51 AI I�.I-200q SEGTION 904.4.
<br /> 2 K N-�2 � �I'`�" L J TU�ING NITROUS OXIDE FROM MANIFOLD AT POINT PI IN TANK ROOM AT 66" UP �ROM
<br /> � 2 l'-4" � � � �,�� � ��__, �LOOR TO R�GE55ED WALL BOXES AT POINT PIA IN OPERATORIES � 24" UP �ROM KN-02 ADA 51NK GOUNTER AT 34" A�F PER IGG/AN51 All7.1-2009 SEGTION 606.3.
<br /> - - � �--r�� �LOOR. (�lERIFY EXAGT LOGATION WITH EQUIPMENT SPEGIALIST.) MANI�OLD AND {�N-03 INSTALL NEW ADA GRAB 8AR(5) IN ADA PATIENT RESTROOM TO MEET GODE.
<br /> � � KN-O6 ''� R�F I ' i ,'i ' �� - �--� N20/02 REGE55ED BOX�S SUPPLIED BY DOGTOR, INSTALLED BY PLUMBER. TEST PROVID� IN-WALL BAGKING A5 NEEDED. PRIVATE RESTRODM TO REGEIVE BAGKIN6 ' �.
<br /> } ' U T I L I T Y c 5 Y 5 T E M �O R 4 8 H O U R S A T 1 5 0 P S I W I T H N I T R O 6 E N. T H E R E S H A L L 8 E N O L E P�K S. U S E
<br /> N � ��� '' � � �, �j /� i FOR �UTURE GRAB BARS. %:
<br /> � � 108 � � � � � � , ; KN-04 ' � NO AIR OR WATER �OR TEST. PLUMBER TO SUPPLY RE6ULATOR AND NITROGEN FOR �
<br /> � , � j T E S T. R E F E R T O N F i'A �i�i G. K N-0 4 E X I 5 T I N 6 G O L U M N T O R E M A I N. P R O T�G T �R O M D A M A G E D U R I N G D E M O L I T I O N f�N D
<br /> "`` ` � NEW GONSTRUGTION. PREPARE SURFAGE �OR NEW FINISH.
<br /> _� I
<br /> m WH ,�M, � �. , �, � � ,, MEDIGfiL GA5 SYST�M TO BE VERIFIED BY 3RD PARTY fi'ER UPG 1302.2 OR
<br /> _ _ _ _ - ' � '� �,A r'� � �- - �-- �I � � , � --� � � � JURISDIGTION'S ADOPTED PLUMBIN6 GODE. KN-OS i'ANO VIEWING WINDOW SIZE: 2'-O"W x 3'-O"H . GLAZIN6 TO BE LEADED OR I/2"
<br /> � 4 _o__;� - � � o J� �- 3'-10" �� �' THIGK TEMPERED GLA55 PER GODE.
<br /> - _ `� " � � ��i �I MATERIALS: � -
<br /> KN-04 2 �� I ' � 4'-8" ! �I KN-04 �' � �; PIPING, TYPE K OR L PREGL�ANED, DEGREASED AND GAPPED TUBING. KN-O6 DENTAL �QUIPMENT BY EQUIPMENT SPEGIALIST. VERIFY ELEGTRIGAL, PLUMBIN6, �
<br /> STERILE � ' �' " ° � i4 = _ / u �� � �' OP � m JOINTS: 51LV�R 50LDER WITH MELTING POINT AT I,000°� MIN. �LARE GOMPRE5510N VENTING ff DATA REQUIREM�NTS. PROVID� NEGE55ARY GONDUIT �ROM GHAIR TO �
<br /> 107 � m �� I KN-O6 2 � 1 I 113 OR THREADED PIPE FITTIN6S UNAGGEPTABLE. 12 O'GLOGK GABINET AS REQUIRED BY EQUIPMENT SPEGIAL15T. ' ev
<br /> O A8.01 O I - --- �
<br /> 3'-O" _�
<br /> I ' SHOW�R , I 13 ' � �J '� KN-O� VERIFY 51Z� AND LOGATION O� BAGKING �OR EQUIPMENT WITH EQUIPMENT `"�' �
<br /> � PIA �'ORTER (OR EQUAL SP�GI�IGATION BY EQUI�'MENT SPEGIALIST) TRIPLE OUTLET 0 �� r.�
<br /> � � SPEGIALIST/ GLIENT. ��°� �
<br /> 2 � 8 � � ' - � II I STATION M41TH OXYGEN, �11TROU5, AND VAGUUM: ��
<br /> A6.01 � 5 �
<br /> � i VERIFY ALL PLUMBIN6 / PIPE REQUIREM�NTS WITH EQUIPMENT SPEGIALIST.
<br /> 6 , � i G � A i KN-OS WALL TERMINATION AT EXISTING WINDOW GLAZIN6 AND/OR WINDOW MULLION: INFILL §� ' "
<br /> � PRIVATE � A8.00 � / � 113 / K�'�� KN-14 WITH GWB AND ADD ALUMINUM END GAP TO EDGE OF WALL AT GLAZING OR �
<br /> m RESTROOM ' KN-02 � y � ., :, �, ' k ,: � KN-ob = D E N TAL E Q U I P M E N T N OT E S MULLION. FINISH TO MATGH WINDOW MULLIONS. 5EE DETAIL ON SHEET A6.01 FOR , �� �
<br /> ., : . ; � ,r �
<br /> :
<br /> m 106 _ _ $ __ � 2 2 � MORE INFO. ° a�
<br /> ( 2 �H`` ; �
<br /> �t- _
<br /> - A ( A � . . �V � � - I. EQUIPMENT SPEGIALIST, GEN�RAL GONTRAGTOR AND ALL SUBGONTRAGTORS SHALL KN-09 PRO�IIDE P�ND INSTALL NEW SEMI-REGESSED �IRE EXTINGUISNER GABINET. VERIFY "�� �,� ; �
<br /> � ,..,_ ., ,
<br /> I �u GOORDINATE �XAGT LOGATIONS AND SPEGIFIG REQUIREMENTS (INGLUDING ELEGTRIGAL, LOGATION 15 AGGEPTABLE WITH �IRE MARSHAL AND T�NANT. SEE 20/A6.01.
<br /> � 106 � � ., : �
<br /> PRIVATE I A8.00 ; ( �� 1O� + � KN-10 / � / � PLUMBING, VENTING, ETGJ �OR DENTAL EQUIPMENT INSTALLATION. VERI�Y ALL �
<br /> O F F I C E ' ; ' A 8.0 0 - �-- z DEDIGATED GIRGUITS # NEGESSARY AMPS OF ALL EQUIPMENT. PROVIDE TEMPLATES K N-1 0 P R O V I D E I N-W A L L SA G KI N G �O R T.V. V E R I�Y L O G A T I O N W I T H G L I E N T P R I O R T O °
<br /> 105 � � KN-14 � � FOR LOGATIONS O� ALL STU�-OUTS AND BLOGKIN6 POINTS �OR EQUIPMENT. GENERAL INSTALL. �
<br /> � 'ii� . � a- � �\ KN-O6 -� -- � GONTRAGTOR TO GOORDINATE, AND 15 RE5PON51BL� FOR, PROPER INSTALLATION O� `�
<br /> � � r- T� Iq Q ALL EQUIPMENT. KN-II PROVIDE IN-WALL SAGKING �OR LEAD APRON HOLD�R. VERIFY LOGATION WITH �
<br /> i Khl-03 ,r- � ! z GLIENT PRIOR TO INSTALL. �
<br /> / i 2. X-RAY 8 PANELIPSE LOGATIONS TYPIGALLY R�QUIRE FRAMIN6 / BLOGKING ON W,ALL TO
<br /> I ' � ' 2 ; , , ' � , A8.01 21 T � � W I T H S T A N D I 5 0 0# T O R Q U E. V E R I F Y B L O G K I N G R E Q U I R E M E N T S A N D L O G A T I O N S W I T H ` �
<br /> � _
<br /> /'
<br /> � r � / / ' , � '= ' � ___ i W KN-12 �ROST�D �l INYL WINDO W D E51GN ON 50UTH AND EAST PERIMETER WINDOWS �OR �
<br /> ,FN., , m „„�A , : / �' , � L EQUIPMENT SPEGIALIST. PRIVAGY. SPEGIFIGATION AND DE51GN TBD.
<br /> r ', DENTA
<br /> �, . �, ,, _ i � ..�.
<br /> _ _ __- 6�1a'11T'- - 12'-�° -"� / / i � m D E NT A L EQ U I P M E NT A P P ROX I M A T E W E IG NTS: �
<br /> VAGUUM: I80 - 275 LB KN-13 GOMPLETION O� DEMISING WALL TO BE PROVIDED BY LANDLORD I� R�QUIRED. �
<br /> A I5 10 8 8'-O" `t ; � Q GOMPRESSOR: I50 - 200 LB WALL TO EXTEND TO STRUGTURE ABOVE WITH 50UND ATTENUATION BLANKET. �
<br /> III ; A6.00 A6.00 A6.00 4-� � A r PANO: 400 LB / FLOOR PLATE FOR PANO: 250 LB VERIFY ALL DETAILS AND REQUIREMENTS WITH BUILDING OWNER. SITE VERI�Y �
<br /> `r 114 ' CONSULT 2 EXISTING GONDITIONS. INSTALL A 51NGLE LAYER O� QUIET ROGK E5 TO INTERIOR
<br /> KN-09 A�� A 1O 3. UTILITY ROOM TO REGEIVE PEMKO #303A5-36X84 SOUND SEAL, #18062GP-36� BRUSH SIDE OF UTILITY ROOM WEST WALL. � ' �
<br /> ' ' �
<br /> i 104 A8.00 114 SW�EP, AND #151A-36X3X1/4 THRESHOLD (OR EQUAL) ON DOOR. 50UND TILE (ARMSTRONG ° �
<br /> _ ° ` P� ���, , q,��2�� 2 #580 GIRRUS OR EQUAL) TO BE GLUED TO ALL VERTIGAL SUR�AGES AND GEILIN6, KN-14 KEEP EXISTING WINDOW TREATMENTS THROUGHOUT WHERE f�PPLIGaBLE. VERIFY ALL �
<br /> _ _ _ _ _ ry o / R�' � WITH GLIENT. .�.m
<br /> M E D G A S -' _ _ 3 � � _; u- INGLUDING THE BAGK OF DOOR. TILE ON DOOR TO REGEIVE M�TAL TRIM GAP. RU88ER
<br /> CLOSET f': � Z 2 KN-04 � y BASE TO BE IN5T,4LLED WITH GLEAR GAULK TO THE �LOOR. Y�RIFY REQUIREMENTS FOR �
<br /> KN-04 r BAGKFLOW PREV�NTERS. PRO�/IDE FLOOR 51NK OR DIREGT DRAIN A5 REQUIRED BY �
<br /> � :,
<br /> 104 � i KN-02 (
<br /> y, „ ,a.F �K �.�_� �� �
<br /> �� �� ���� �� - JURISDIGTION. V�NT TO EXTERIOR. `�
<br /> �_ � ' �
<br /> � i < � = KN-10 ° � 4. PROVIDE IN-WALL BLOGKING �OR LEAD APRON HOLDERS IN PANELIPSE / X-RAY ROOM �
<br /> � ADA PATIEN -� ' ; � � � ' � � I AND OPERATORIES A5 NOTED ON �LOOR PLAN.
<br /> RESTROO � Ku-os 2 � �
<br /> KN-14 �
<br /> v 103 I I ��_pb 5. GG TO VERIFY LEAD LIN�D WALL REQUIREMENTS AT X-RAY EQUIPMENT WITH GLIENT AND ' �
<br /> �-- � � EQUIPM�NT SP�GIALIST. �
<br /> 4 � I
<br /> � ;'
<br /> � I 3 I I �Q 6. PROVIDE PLASTER TRAPS AND OTH�R DENTAL RELATED PLUMBIN6 N��DS WHERE �
<br /> r / \ \ �
<br /> i A8.00 2 / 1O3 i �' N ��' AS.OI 2I - � � NEG�55ARY. VERIFY WITH EQUIPMENT SPEGIALIST. �
<br /> �
<br /> 10 2 6'-D" - � , I � �, G- � 7. DENTAL EQUIPMENT IS SEL�-GONTAINED AND DOES NOT GONNEGT TO RNY DOM�STIG ��
<br /> A6.01 � � = WATER SUPPLY. �
<br /> ; , r,�,,, , ::.. ' � 2 / I i �y stg
<br /> . ,.
<br /> � W �� � 8. THERE WILL BE NO �ILM DEVELOPIN6 EQUIPMENT AT TH15 LOGATION.
<br /> - ;: � � -
<br /> l / � °�� 1 - -- � ' �
<br /> - - - �- ; � � � '; 9. IF REQUIf�D BY GODE, INSTALL SEPARATE GROUND WIRE TO ALL TRE,4TMENT ROOMS.
<br /> �/ SEE EQUIPMENT SPEGIALIST'S PLAN �OR ELEGTRIGAL NOTES FOR ALL EQUIPM�NT.
<br /> �� X-R A Y � - � 10.PROVIDE GONDUIT �OR A L L EQUIPMENT A S REQ UIR E D. V E R I FY S I Z E A N D L O G A T I O N W I T H
<br /> ,
<br /> � �' � 12 WALL TYPE SCHEDULE
<br /> 1 � 102 ��� '� A8.00 , A I,II I LOW VOLTAGE SPEGIALIST AND EQUIPMENT SPEGIALIST.
<br /> � � CONSULT 1
<br /> / � 115 II. GALL SYSTEM PANELS (I� APPLIGABLE) REQUIRE A GONDUIT RUN AND POWER PROVIDED �
<br /> m �\ __ / , q 2 . 115 BY THE ELEGTRIGIAN. LOGATIONS TO BE VERI�I�D ONSITE BY DOGTOR. 5EE PLAN FOR N�'� DESGRIPTION _ HEIGHT R,4TING
<br /> � � -
<br /> i�� GENERAL LOGATIONS. VERIFY WITH GLI�NT AND EQUIPMENT SPEGIALIST.
<br /> _ _
<br /> ��� ,,. „; , I O �IEW INTERIOR WALL GONSTRUGTION T't'P. TO 6" ABOVE NON-RATED
<br /> KN-05 ; �� ...r.r � :� .. � ,n�e-, .... ,..�. � ,r �
<br /> ; - KN-O6 i �IN15H PER SGH�DUL� GEILING 5EE
<br /> - � ' 5/8" Tl'PE 'X' GYPSUM WALL BOARD 12/A6.00 `� �
<br /> � ���� � -� 6�'�° ; KN-OS 3-5/8" STEEL 5TUD5 PER LGMF MANUAL/SGHEDULE
<br /> � _
<br /> �� -- � � 'n � 5/S" TYPE 'X' GYPSUM WALL BOARD
<br /> �, f , �
<br /> � ' FINISH PER SGHEDULE
<br /> _ . � i KN-04 ; I'-�" 2 KN-14 '
<br /> -----
<br /> � i A8.02 ;
<br /> ° N �.�
<br /> � - m �'o B m � GH�GK-OUT � 2 NEW INTERIOR 50UND / DEMISING WALL TO UNDER5ID� NON-RATED
<br /> IOI ry KN-04 ;
<br /> O GONSTRUGTION OF FLOOR
<br /> _ ..:; � RECEPTIO �INISH P�R SGHEDULE STRUGTURE
<br /> - -
<br /> 5/8 QUIETROGK ES GYPSUM WALL BOARD 5E� 13/A6.00 , ,
<br /> � 116
<br /> �___- _- -
<br /> ,�
<br /> 3-5/8" STEEL STUDS PER LGMF MANUAL/SGHEDULE
<br /> 6�4 ' 4'-O° + 50UND BATT INSULATION
<br /> � 5/8" TYPE 'X' GYPSUM WALL BOARD
<br /> cv �IN15H PER SGHEDUL�
<br /> �-- �t � � --
<br /> O3 NEW INTERIOR WALL GONSTRUGTION TO UNDER5IDE I-HOUR RATED
<br /> �IN15H PER SGHEDULE OF FLOOR
<br /> � i_--______ KN-OI --- 5/8" TYPE 'X' GYPSUM WALL BOARD STRUGTURE
<br /> � 3-5/8" STEEL 5TUD5 PER LGMF MANUAL/SGHEDULE 5E� 14/A6.00
<br /> \ A 5/8" TYPE 'X' GYPSUM WALL BOARD
<br /> \ 101 2 A8.02 2 / I� FIN15H PER SGH�DUL�
<br /> � A8.02
<br /> ��'.
<br /> _-- 3'-4I/2" j I
<br /> � FLOOR PLAN LEGEND ���
<br /> KN-12 KN-10 _,�1 � -- - ;
<br /> 23
<br /> KN-14 � �/'� �- � � I � ���
<br /> I� � � �
<br /> � � � i �" ���
<br /> 6 � ' _ / � �' � EXI5TIN6 WALL �� �
<br /> � ��
<br /> � , � �-.� � ._� �dt��. �. ���
<br /> ,. 2 3
<br /> --- ��� � 7'-7° i I .
<br /> - � - NEW NON-LOAD BEARING PARTITION WALL.
<br /> -- - --
<br /> - - -
<br /> ___
<br /> - - - - -
<br /> � FA/ BUSINESS � ! ALL PARTITIONS TO B� TYPE "I" UNLE55 NOTED. REV DESCRIPTION DATE
<br /> iI WAITING OFFICE / '� � 5EE DETAILS ON SHEET A6.00 �OR MORE IN�O. PERMITSET 09127I2017
<br /> � 101 117 � � � > �: �� 1 REVISION-PERMIT COMMENTS 10113117
<br /> Ji � I � I � v- � � , / NEW MILLWORK
<br /> , - - -- � /� '% i � ;
<br /> � i� � �� �.:
<br /> - KN-12
<br /> - ��h
<br /> - - a�
<br /> .;�� �
<br /> 5U5PENDED N KN-14 F" �`��
<br /> � ��;. �
<br /> ���
<br /> � �ROM GEILING , - N20/ 02 LINES � -��� �
<br /> 8
<br /> A8.02 XXX ` ���� �
<br /> --- DOOR TAG - SEE DOOR SGHEDULE ON SHEET AQ.00 : ��f
<br /> ----� ----_ ______ __ XXX
<br /> A._ r-
<br /> 12'-6 3/4"± KN-12 14'-II"VIF II� � 1
<br /> XO WINDOW TAG - 5EE WINDOW SGHEDULE ON SHEET A9.00 FLOOR PLAN
<br /> I'-3°
<br /> i
<br /> �E �IRE EXTINGUISHER GABINET
<br /> FLOOR PLAN �
<br /> � o NEW ELEGTRIGAL PAN�L
<br /> -- - A3.01 SGALE: I/4" = I'_O" PROJECT NUMBER: A17•368 10113117
<br /> �FREIHEIT 8 HO ARCHITECTS, INC., P.S.
<br /> C:IUserslbrittanybrownllocal settingsltemplAcPublish_48241A17-368_STIVERS-A0.00 PRMT-SET.dwg Oct 13,2017-1:01 pm brittanybrown � I I I
<br />
|