REVISIOIV
<br /> ACCESSIBLE SYMBOLS KEY RESTROOM GENERAL NOTES
<br /> DATE IN
<br /> NO SCALE
<br /> ,/'^ 1. TOILET ROOM PLAN & ELEVATIONS ILLUSTRATE FIXTURE CLEARANCE DIMENSIONS, MOUNTING HEIGHTS AND ACCESSORY ,
<br /> � � PLACEMENT. ACTUAL lAYOUT MAY VARY. SEE FLOOR PLAN FOR CORRECT LAYOUT.
<br /> � � ( MANEUVERING CLEARANCE 2• LOWER EQGES OF LAVATORY TO BE 2'-3" MIN. ABOVE FINISH FLOOR FOR KNEE CLEARANCE.
<br /> � 60"X59" CLEAR FLOOR � — SIDE APPROACH AT HINGE, PUSH 3. MIRROR TO BE MOUNTED 3'-4" MAX. ABOVE FINISH FLOOR.
<br /> I, � SPACE � FLOOR MOUNTED SIDE OF DOOR 4. GRAB BARS TO BE 1-1/4" - 1-1/2" IN DIAMETER, MOUNTED 1 -1/2" FROM WALL BARS SHAL� BE CAPABLE OF
<br /> i � TOILET � � SUPPORTING 30OLB LIVE LQAD WITHOUT PERMANENT DEFLECTIQN.
<br /> L � i � � 5. LA'VATORY RIM TO BE 34" ABOVE FINISH FLOOR. 8�-9� 8-9„
<br /> �
<br /> � � „ „ � ' � 6. FLOORS SHALL BE SMOOTH, HARD, NON-ABSORBENT SURFACE SUCH AS SHEET VINYL OR OTHER AS ACCEPTABLE BY
<br /> 30 X48 CLEAR FLOOR
<br /> ( SPACE � SINK - ,�-- LOCAL HEALTH AND BUCLDING DEPARTMENTS. FLOORING MATERIAL MUST EXTEND ONTO THE WALLS AT LEAST 6". SEE FINISH
<br /> VERTICAL APPROACH ; SCHEDULE FOR MORE INFORMATION. ' ; � � � ry z
<br /> { '
<br /> I— .�I 1 7. DIMENSIONS, NOTES AND EQUIPMENT TYPICAL FOR ALL TOILET ROOMS, UNLESS NOTED OTHERWISE. � � ' ; ; � � �, ; ;` , , B � -
<br /> � e � a � � � z � 1 , �
<br /> i \ �` � � c � RESRObM ! � �2ES;TR00�, c � z � � �
<br /> 8, SEE FINISH SCHEDULE ON SHEET A6 FOR FINISH INFORMATION.
<br /> �.. � — � ��� o i i ��3� i � i 1��2 i s � �r
<br /> MANEUVERING CLEARANCE g, TOILET ROOM FAN TO BE INTEGRALLY SWITCHED WITH TOILET LIGHT AND VENTED TO THE OUTSIDE. �� ', �--�- -,-�---� _ `-- �.--�`J ,' �--�' r �-
<br /> �--- � SIDE APPROACH AT LATCH, PUSH -----�------� % � ,� �-----_� Q
<br /> � ' � FORWARD APPROACH i i SIDE OF DOOR 10. CONCREfE OR CMU WALLS IN TOILET ROOMS SHALL BE FURRED OUT AND FINISHED SIMILAR TO ADJACENT WALLS.
<br /> � OPENING ARE LOCATED 40" MAX. _ � �
<br /> ! + MANEUVERING CLEARANCE � � 11 . PROV{DE PAPER TOWEL DISPENSER. UNIT TO BE MOUNTED SO THAT CONTROLS OR � �' o" � W Z
<br /> � ' @ PULL SIDE OF DOOR � J ABOVE FINISH FLOOR.
<br /> i
<br /> � 12. GYPSUM BOARD APPLIED TQ PLUMBING WALLS SHOULD BE WATER-RESISTANT. , , �� O�C � Q
<br /> ---_
<br /> � '� �� 13. WATER CLOSET FLUSH VALVE TO BE ON OPEN SIDE OF TANK.
<br /> � �
<br /> ' ' � 14, PROVIDE BLOCKING AS REQUIRED TO SUPPORT SINK, GRAB BARS, ANQ �THER HARDWARE. � �
<br /> FORWARQ APPROACH l „ �
<br /> W '
<br /> i MANEUVERING CLEARANCE � 60 TURN AROUND CIRCLE 15. TOI�ET PAPER DISPENSERS SHALL BE LOCATEQ 7'-9" MIN. IN FRONT OF WATER CLOSET, MEASURED TO THE �
<br /> � W W
<br /> � C� PUSH SIDE OF DOOR � � � CENTERLINE OF THE DISPENSER. OUTLET SHALL BE 15" MIN AND 48" MAX ABQVE FINISH FLOOR. THERE SHALL BE E— N �
<br /> W
<br /> -- -� 1-1/2" MIN. CLEARANCE BELOW AND 12" MIN. ABOVE THE GRAB BAR. � O�i �
<br /> 16. OTHER DISPENSERS AND DISPOSAL FIXTURES SNALL BE LOCATED 40" MAX. ABOVE FINISH FL00 , Y RESTROOM PLAN RESTROOM PLAN �t. � W
<br /> RACK, OPERATING CONTROL, RECEPTACLE OR DISPENSER. � SCALE: 1/2" = 1'-0" � SCALE: 1/2" = 1'-0"
<br /> 17. WALLS WITHIN 2 FEET OF URINALS AND WATER CLOSEfS SHALL HAVE A SMOOTH, HARD, NON-ABSQRBENT SURFACE
<br /> TO A HEIGHT OF 4'-0" ABOVE FINISH FLOOR.
<br /> .
<br /> ACCESSIBLE � �
<br /> � �
<br /> RESTROOM SIGN �
<br /> No scALE VANITY LIGHT � Q
<br /> DEMO AND INFILL Q PER LIGHTING OBSCURE �� �
<br /> � �- irt------� NOTED PORTION OF PLAN/SCHEDULE GLASS O 5 O � �
<br /> i EXISTING WINDOW
<br /> � �
<br /> ° - - TO ALLOW FOR - vs
<br /> '� �i ,/ . . TOILET SEAT COVER MIRROR , � v
<br /> ,� VERTICAL GRAS BAR � DOOR � .r,
<br /> ` DISPENSER �'
<br /> � , � INSTALLATION PER PAPER TOWEL : � � : ' ` HOOK � � �
<br /> � GRAB BAR - CODE. SOAP 24 X 36
<br /> '-3" (39"�t" GRAB BAR MIRROR n-s DISPENSER '� � �
<br /> �
<br /> �5 DISPENSER - 3'_>>" �� � o0
<br /> � 15' ' ' __ � o ` � _ � � M
<br /> _ _ .
<br /> �r �� �!` PAPER TOWEL
<br /> BABY CHANGING �. , , z ; -_ '`' . __ 4� � M
<br /> STATION: MOUNT PER � � - > �, t� $
<br /> � � � � � H f
<br /> ADA REQUIREMENTS -� �� y` _ , , � f ' BABY CHANGING STATION: � ''� �
<br /> . � � �
<br /> .. � , , � ���� � ; � ' C � � MOUNT PER ADA � � N�/�
<br /> `�. ,-S r r' � W
<br /> � REQUIREMENTS �
<br /> .. � r �,� o Y .--�
<br /> ;<
<br /> Al1 HANDICAP ROOMS TO HAVE SIGNAGE PER ICC 1101.2.9. " ��` � ��.�; � �� ' �` N ; , )
<br /> (ICC A117.1 SECTION 703.6.3.1) ALL INTERIOR SIGNS DEPICTING � =�`�������� Z �
<br /> . r ,.. . _ _ < _ � Q-+ N
<br /> THE INTERNATIONAL SYMBO� OF ACCESSIBILIIY SHALL CQMPLY � ° �-� �
<br /> , � 3 � , � � ¢ a � ._ � � � �
<br /> WITH SECTION 703 (ICC A117.1 SECTION 703) � � r '' �
<br /> � .
<br /> a ^ o R i � � I � ,1 � �- �+- Y i \ i.i. �� �
<br /> ih _ �p I � n co I i . � Z e � ti Z �'"� ; \ ^,
<br /> I x p) M � � Of M �.,l � ¢ Cn � j�r� �Q t1) ��i Q \ V
<br /> ALL ACCESSIBLE SIGNAGE DEPICTING THE INTERNATIONAL SYMBOL ;�, � i F i _ i =� z � � ,� � z ,� `� - � �-+
<br /> OF ACCESSIBILIIY SHALL BE WHITE ON A BLUE BACKGROUND � Q, N M �' "' ,� � � � `�' � � ""�t� �
<br /> PER 1101.2.9 IN THE WA STATE AMENDMENTS TO THE IBC. N " i " � " N _� o � o `� , __ 7 __ __ __ . ____ i___ I
<br /> _ _ __ W
<br /> s. , : , � 1 i � ,_ r . I N H- ~ a i � 1 S I ! _ , �� N
<br /> -� � �
<br /> MOUNT ACCESSIBLE SIGNS 40" M�N AF.F., MEASURED TO THE `n �6� I � � ( � � � ' ' 6 ' f � ' � � � �� �
<br /> �
<br /> �
<br /> BpSEUNE OF THE CHARACTER PER ICC/ANSI 117.1-2009 � r--+
<br /> sEcr�aN �a�.4.5 TOILET PAPER GRAB BAft TOILET PAPER i'-6" INSULATE HOT 2'-��" � �
<br /> GRAB BAR DISPENSER DISPENSER (16"-t8») WATER PIPES & "� �
<br /> DRAIN �
<br /> ELEVATIC)N ELEVATION 1 ELEVATION 1 ELEVATION
<br /> 1 SCALE: 1/2" = 1'-0" � � SCALE: 1/2" = 1'-0" 1 � SCALE: 1/2"' = 1'-0" 1 � SCALE: 1/2" = 1'-0"
<br /> �sT�ooM
<br /> VANITY LIGHT
<br /> PER LIGHTING O 5 0 OBSCURE GLASS �
<br /> PLAN/SCHEDULE
<br /> � � TOILET SEAT COVER DOOR MIRROR
<br /> -
<br /> DISPENSER HOOK \ : . �
<br /> GRA BAR �0 24 X 36 SOAP : � PAPER TOWEL
<br /> GRAB BAR DISPENSER 3'->>„
<br /> 3'-3� (39"-41") � ,
<br /> A-s MIRROR DISPENSER �5
<br /> __ __ : 15 _ __ _ ._ /�__ _ _ ,. � ` . .,
<br /> __ _ o
<br /> � ,,: W ' ' i�
<br /> BABY CHANGING PAPER TOWEL Z
<br /> � } STATION: MOUNT PER HOLDER �
<br /> � - - - -
<br /> � . � � ' �� l'� �
<br /> ADA REQUfREMENTS � � BABY CHANGING STATION:
<br /> ` �,
<br /> _�_ , . ' MOUNT PER ADA � f
<br /> -- � ,� � ,
<br /> o � ,
<br /> , REQUIREMENTS
<br /> r f �
<br /> � _ _ � � __ �. _ RE S TROO
<br /> �,�, � . ,
<br /> Z - , :, � ___
<br /> ¢ � � W DETAILS
<br /> � o . � o � �. � � �
<br /> �
<br /> � � ` .� � - � � � `` Z � � _ '� % i �- � Z '�-
<br /> � � � -� � � Q � �.a � _r- ¢ `�', ¢ ��
<br /> 1 1 `� � M I x t� o cv '�rh j� o o r�
<br /> cv � ^1 �"� o O 'I ;�D I � d-
<br /> � N ( d �1 M / (
<br /> I ' . ' O j._ _ . _ - - � _ -` - - _�_ � _ � _ ___ , - -
<br /> / �
<br /> � - � - _ N ..
<br /> � r � `� '— � � E 6 � �� � T i 1 , cv � ( � -� T -� . �6 -� � _���
<br /> Date• Ol 18 17
<br /> i 1 ; �s � �
<br /> Scale: NOTED
<br /> GRAB BAR TOILEf PAPER 2'->>" INSULATE HOT �'-6" TOILEI PAPER �'�
<br /> DISPENSER GRAB BAR
<br /> WATER PIPES & (16"-18°) DISPENSER Drawn by: SG
<br /> DRAIN Job: FLAT JAX
<br /> � ELEVATION ELEVATION ELEVATI�N ELEVATION EVEREfT WA
<br /> � (�' �
<br /> `� �� SCALE: 2/2" = 2'-0" v SCALE: 2/2" = 2'-0" � SCALE: 2/2" = 2'-0"
<br /> � o SCALE: 2/2" = 2`-0" �
<br /> N
<br /> � �
<br /> � RESTROOM
<br /> 0
<br /> N
<br /> \
<br /> �
<br /> r-1
<br /> \
<br /> �
<br />
|