Laserfiche WebLink
SNOHOMISH <br />HFAITH DISTRICT <br />W W W.SNOHD.ORG <br />May 30, 2014 <br />Jered I ucker, <br />1220 Marshall St NE <br />Minneapolis MN 55413 <br />Environmental Health Division <br />B m s-Uzi n <br />Subject: Proposed Target #T-0337 Starbucks Remodel, 405 SE Everett Mall Way, Everett, WA <br />Dear Mr. Tucker: <br />Your plans have been reviewed with the Rules and Regulations of the State Board of Health, and with <br />the policies of the Snohomish Health District. With the addition of the following conditions, the plans <br />are approved. <br />1. The conditional approval of the plans for Target was based upon the plans submitted May 14, <br />2014. Any changes to the plans submitted May 14, 2014 will void this approval. <br />2. If the establishment continues to be in operation during the remodel, dust barriers must be installed to <br />ensure that food protection and safety is not compromised. The establishment will be required to <br />discontinue operations if any disruption in water, electrical, or sewer service occurs due to the remodel. <br />Proper handwash stations must be kept accessible and functional during all hours of food service <br />establishment operation. <br />3. An indirect waste drain (an air gap) is required for the three -compartment sink, mechanical dishwasher, <br />ice machine, ice bins, running water dipper well and espresso machine. <br />4. The hand sink on the service line, (Item #SB0931), is located between a coffee grinder, (Item #SB0017) <br />and an oven (Item #SB0208). Because of this, a horizontal separation of at least 16 inches or a vertical <br />partition 16 inches in height is required between the hand sink and the equipment. <br />5. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks and at. <br />the same time provide hot water to all hand sinks. <br />6. Hot water must be available to all hand sinks within 15 seconds. The hot water for the facility must not <br />be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. This is <br />required so that proper testing of the 15-second time requirement for hot water availability can be <br />completed. <br />7. All food service equipment, both new and used, must be listed by the National Sanitation Foundation <br />(NSF) or equivalent for its intended use. Used and new refrigeration must be capable of holding food at <br />a temperature of 41 F or below. <br />8. Extra wall protection is required on walls behind all sinks, including restroom hand sinks, and food <br />preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass -reinforced <br />plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall behind <br />counter top equipment taller than 16 inches. Floor to ceiling protection is required on the wall behind <br />dishwashers. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br />hardboard is not acceptable. <br />9. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be <br />surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts <br />and the like in concrete floors in all areas, including customer seating areas, must be filled and sealed so <br />as to provide a smooth and cleanable surface. <br />3020 Rucker Avenue, Suite 104 ■ Everett, WA 98201-3900 ■ tel: 425.339.5250 ■ fox: 425.339.5254 <br />