My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3621 BROADWAY CRICKET 2019-01-17
>
Address Records
>
BROADWAY
>
3621
>
CRICKET
>
3621 BROADWAY CRICKET 2019-01-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/17/2019 3:44:09 PM
Creation date
1/17/2019 3:44:05 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3621
Tenant Name
CRICKET
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C , <br /> FN DESCRIPTION QTY <br /> 1 24" CRICKET LETTERSET ON RACEWAY W BACKGROUND PANEL 1 <br /> 2 03/8`[10] S.S. THREADED ROD C 12 [305] LONG W/ HARDWARE 10 <br /> 8'-10 3/8" [2702] 3 TOUCH-UP PAINT A/R <br /> BACKGROUND PANEL 4 POUNCE PATTERN (SEND FULL-SIZE PAPER COPY OF MOUNTING PATTERN) 1 <br /> 7- FABRICATED ALUMINUM 5" [127] 5 CARDBOARD BOXES (PACKAGE INSTALL KIT, EXCEPT POUNCE PATTERN) A/R <br /> CHANNEL LETTER — 6 CARDBOARD TUBE (PACKAGE POUNCE PATTERN) i <br /> 4 1/2" 7 INSTALL DRAWING (PRINTED 11"x17") i <br /> o [114] <br /> O a \ 0 \ 0 BRAKEFORMED-STYLEU TINGALUCUM <br /> \ g U-STYLE MOUNTING CUP RACEWAY NOTE: <br /> I O N N in (2" WIDE x 1/8" THICK) ALL RACEWAYS TO BE PAINTED TO MATCH <br /> n dol 0 0 0 dol o o dol o o dol PAINTED TO MATCH RACEWAY CORRESPONDING FASCIA COLORS. <br /> C <br /> IN n I"I 4 .040 ALUMINUM — <br /> 1 I PRINCIPLE 360 LABEL RETURN 5" [127]�� <br /> 4 1/2" [115] <br /> `I o O a o O o o O o 0 0 0 o p o p 0 <br /> 2OA SWITCH 1" JEWEC P <br /> ° ' ' LE in TRIM CAP e <br /> • <br /> ELECTRICAL ENTRANCE MOUNTING LOCATION— THIS LEITER SECTION GREEN VINYL, `RACEWAY d <br /> UL LABEL <br /> TYPICAL TYPICAL ALL OTHER LETTER SECTIONS TO BE 20A SWITCH RACEWAY <br /> BLACK DUAL COLOR - <br /> 9'-3 1/16" [2820] .080" ALUM <br /> BACKGROUND PANEL <br /> SUPPLY WIRE M�tliii. <br /> ELEVATION VIEW SIDE VIEW <br /> INSTALLATION INSTRUCTIONS: <br /> 1. SECURE POUNCE PATTERN TO WALL. BRAKEFORMED ALUMINUM <br /> 2. DRILL MOUNTING AND ELECTRICAL HOLES INTO WALL. U-STYLE MOUNTING CUP <br /> 3. INSTALL WATERPROOF CONDUIT FOR ELECTRICAL. GOQ LED MODULE (2" WIDE x 1/8" THICK) <br /> 4. MOUNT LETTERS/RACEWAY TO WALL AS SHOWN. PAINTED TO MATCH RACEWAY <br /> 5. ADD A BEAD OF NON-HARDENING CAULK AROUND (ATTACHED BEFORE SHIPPING) <br /> EACH HOLE WHERE MOUNTING HARDWARE S.S. MOUNTING HARDWARE CHART <br /> PENETRATES THE WALL TO INSURE WATER TIGHTNESS. <br /> 6. MAKE ALL PRIMARY ELECTRICAL CONNECTIONS. Oa41-y/ <br /> O� <br /> 7. TEST LIGHT SIGN. OO ,P <br /> 8. ATTACH WIRE AND POWER SUPPLY COVERS. <br /> 9. CLEAN SITE OF ALL INSTALLATION DEBRIS. 3/8" BOLTS THRU WALL * * * 3/16"LACRYLICR E <br /> 10. CLEAN SIGN. <br /> 11. INSTALLATION TO MEET ALL CODE REQUIREMENTS. <br /> 3/8" LAGS W/SHIELDS - <br /> 3/8" LAG BOLTS * <br /> 3/8" TOGGLE BOLTS * .063 ALUMINUM BACK <br /> SECURE W/ 03/8" S.S. <br /> DIMENSIONS ON THIS DRAWING ARE DISPLAYED 7-MECHANICAL FASTENER AS <br /> IN ENGLISH UNITS FOLLOWED BY METRIC UNITS REQUIRED PER SITE <br /> IN BRACKETS. ALL METRIC UNITS HAVE BEEN <br /> ROUNDED TO THE NEAREST WHOLE MILLIMETER. I I CONDITIONS <br /> 3/16" DIA. S.S. RIVET <br /> CRATES AND WEIGHTS WATERPROOF CONDUIT TO <br /> AREA: 22.0 SQ FT (2.1 SQ METERS) PRIMARY ELECTRICAL SOURCE <br /> ESTIMATED CRATED VOLUME: 36.6 CUBIC FT (1.0 CUBIC M) - /BY INSTALLER <br /> ESTIMATED CRATED WEIGHT: 111 LBS (50.3 kg) 7/8" PLASTIC BUSHING •_• <br /> CONSTRUCTION & INSTALLATION OF ESTIMATED UNCRATED WEIGHT: 75 LBS (34.0 kg) .. <br /> CAULK INSIDE ALL LETTERS INCHANNEL LETTERS SHALL CONFORM <br /> TO ALL UL, NEC, CSA AND LOCAL W/ BLACK SIUCONE CAULK <br /> CODES <br /> SIGN ELECTRICAL INFORMATION <br /> LEDs: (43) GOQ 3 LED �" LED POWER SUPPLY <br /> LED POWER SUPPLY: (1) MEANWELL LPV-60-12 1/4" DIA. WEEP HOLE ---11�❑ <br /> TOTAL CONNECTION LOAD: 1.2A C 120V WITH UGHT COVER I SI Y' I <br /> POUNCE PATTERN SHALL BE SUPPUED CIRCUITS REQUIRED: (1) 20 AMP I.080 ALUMINUM BACKGROUND <br /> BY LETTERSET MANUFACTURER. ALL ELECTRICAL COMPONENTS TO BE UL LISTED PANEL PAINTED WHITE <br /> GROUNDING PER UL AND NEC SPECIFICATIONS RACEWAY (COVER <br /> FACES DOWNWARD) <br /> }" DRAIN HOLES <br /> LETTER SECTION DETAIL <br /> CRICKET CR -FL -24B -BP-R (INSTALL) ,,-- <br /> / <br /> 24 " ALA CK FACE-LIT CHANNEL LETTERS ON RACEWAY W BACKGROUND PANEL ( I- 0417i <br /> _ <br /> Principle Group The following document is for design intent - ---- --- - injc h:As <br /> �0 E <br /> 2035 Lakeside Centre Way <br /> purposes only and is the intellectual property E 8-24-17 CEC-Q INVERT RACEWAY. REMOVE REMOTE POWER SUPPLY AND BOX FROM SHIPPING UST. Latest Revtsion: <br /> of Principle Group. It shall not be reproduced <br /> Suite 250 and/or distributed for any purpose without prior D 8-1-16 JLS CHANGED BACKGROUND PANEL THICKNESS FROM .125 TO .080 ALUMINUM, Drawing by:JLS Date:06/16/2014 <br /> T N 3 7 9 2 2 written approval. CHANGED RACEWAY SPEC TO EASTERN METAL SUPPLY 4-1/2"x4-1/2" <br /> 0 pKnoxville, The manufacturer Shall be C 4-21-16 JLS CHANGED ELECTRICAL SPECS TO GOQ Descrt tion: ifNf -Ealal1111I/BEO <br /> jro rcj11 , F, Main : 865.692.4058 responsible for all structural, electrical, P <br /> mechanical, and foundation engineering. B 11-24-14 JLS CHANGED LOCATION OF MOUNTING HOLES TO MATCH ACROSS EACH LEITER VERSION <br /> Toll— free: 877.692.4058 These documents were not produced under an A 9-23-14 JLS REVISED LETTER SECTION DETAIL, ADDED CRATES & WEIGHTS, ELECTRICAL INFO Customer. CRICKET <br /> www.principleglobal.com engineering services agreement. RTP 6-19-14 JHP DRAWING CHECKED & APPROVED (` Q <br /> Rev Date Initials Description of change Sht 1 of 1 Drawing: 0 0 9 3 7 0 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.