My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3625 8TH ST 2019-01-18
>
Address Records
>
8TH ST
>
3625
>
3625 8TH ST 2019-01-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2019 3:04:40 PM
Creation date
1/18/2019 3:03:11 PM
Metadata
Fields
Template:
Address Document
Street Name
8TH ST
Street Number
3625
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
720
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
° ° Component Performance Path, pg. 2 ENV-UA <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: CROSSDOCK FACILITY Date 12/29/2016 <br /> Fenestration Area as%gross above-grade wall area 6.3% Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> Building Component Proposed UA Target UA <br /> Ins.R I Plan/Detail#1F-factor Source&Table#8 F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> v R=15 1/A3.16 0.540 305 164.7 0-540 I 305 I 164.7 <br /> m t R= Slab-On-Grade F-0.54 <br /> 66 R= <br /> 9 .a R= 0.550 <br /> a' m R= Heated Slab-On-Grade F-0.55 <br /> = R= <br /> Schedule ID U-factor Source9't0 U-factor x Area(A) =UA(U x A; U-factor x Area(A)= UA(U x A) <br /> Break Room 102-D-11 0.370 24 8.9 0.37 I 24 8.9 <br /> co <br /> Opaque Swing Doors U-0.37 <br /> c <br /> 3 <br /> 0 <br /> 0 <br /> oI <br /> 0 0.34 <br /> iii <br /> Opaque rollup&sliding U-0.34 <br /> O <br /> T 0.30 I i <br /> iv Non-Metal Frame U-0.30 <br /> 0 <br /> z • <br /> o, Vestibule 112 Door A 1 0.38 252 95.8 0.38 I 252 I 95.8 <br /> • <br /> Ls Storefront W3/A3.01 Metal Frame,Fixed U-0.38 <br /> H- <br /> 0.40 I <br /> o Metal Frame,Operable U-0.40 <br /> 0 <br /> To <br /> CD c <br /> 0 <br /> U 0.60 <br /> E Metal Entrance Door U-0.60 <br /> c <br /> 0 <br /> E <br /> GN 0.50 <br /> s T All types U-0.50 <br /> 'T <br /> u) <br /> Q <br /> Area' UA • Area' UA <br /> Page 2 Subtotal 581 269 581 269 <br /> Pagel Subtotal 9400 335 9400 609 <br /> TO COMPLY-The Proposed Total UA shall not <br /> exceed the Target Total UA. Project Total 9981 604 9981 878 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> Note 1-If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> Note 2-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br /> Note 4-For semi-heated spaces utilizing the wall insulation exception,enter Target Wall U-factors under Proposed Wail U-factors so exterior <br /> walls are neutral to the calculation. <br /> Note 5-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 6-Demising walls,doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned,semi-heated, <br /> fully conditioned)shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here. List all other mass walls,Commercial and Group R,in the Opaque Walls-Above Grade section. <br /> Note 8 -Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 -Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating,which includes the glazing and frame,or shall be <br /> the default value per Section C303.1.3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.