Laserfiche WebLink
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 2016 <br /> Project Title: Fill this line out on LGT-SUM Date 7/1/2016 <br /> Calculation Q Q Addition- Q Addition For Building Department Use <br /> Area NOTE s stand alone +existing <br /> 0 Spaces where<50Tof Spaces where°50%of <br /> luminaires are replaced luminaires are replaced <br /> LPA ® Standard 0 Additional Efficiency Package Option 0 <br /> Calculation C406.3 Reduced Interior Lighting <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> OFFICE 322 Office:Enclosed 180 0.890 160 <br /> OFFICE 314 Office:Enclosed 230 0.890 205 • <br /> OFFICE 318 Office:Enclosed 154 0.890 137 <br /> CONF RM 315 Conference/meeting/multipurpose 156 0.980 153 <br /> OPEN OFFICE Office:Open plan 480 0.780 374 <br /> 330 <br /> OFFICE 321 Office:Enclosed 168 0.890 150 <br /> Total Area 1368 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTES Allowed Watts 1179 <br /> Proposed Lighting Wattage NOTE a <br /> Location(plan#, Number of Watts/ ,`f� # Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 "4,1r.::744e4rtec Proposed <br /> OFFICE 322 TYPE A2 2 60t 120 <br /> OFFICE 314 TYPE A2 3 60i' 180 <br /> OFFICE 318 TYPE A2 2 60 'It i 120 <br /> -t44.*;*.W.1 <br /> CONF RM 315 TYPE A2 2 604410,r WV 120 <br /> j.OPEN OFFICE TYPE Al 14 30 r , s0 420 <br /> OFFICE 321 TYPE A2 2 60 ,_T " .{ ti 120 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1080 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> liohtino systems to demonstrate compliance.Refer to C502.1. j <br />