My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2320 CALIFORNIA ST BASE FILE 2019-01-24
>
Address Records
>
CALIFORNIA ST
>
2320
>
BASE FILE
>
2320 CALIFORNIA ST BASE FILE 2019-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2019 2:53:23 PM
Creation date
1/24/2019 2:53:16 PM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
2320
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 2016 <br /> Project Title: Fill this line out on LGT-SUM Date 7/1/2016 <br /> Calculation Q Q Addition- Q Addition For Building Department Use <br /> Area NOTE s stand alone +existing <br /> 0 Spaces where<50Tof Spaces where°50%of <br /> luminaires are replaced luminaires are replaced <br /> LPA ® Standard 0 Additional Efficiency Package Option 0 <br /> Calculation C406.3 Reduced Interior Lighting <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> OFFICE 322 Office:Enclosed 180 0.890 160 <br /> OFFICE 314 Office:Enclosed 230 0.890 205 • <br /> OFFICE 318 Office:Enclosed 154 0.890 137 <br /> CONF RM 315 Conference/meeting/multipurpose 156 0.980 153 <br /> OPEN OFFICE Office:Open plan 480 0.780 374 <br /> 330 <br /> OFFICE 321 Office:Enclosed 168 0.890 150 <br /> Total Area 1368 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTES Allowed Watts 1179 <br /> Proposed Lighting Wattage NOTE a <br /> Location(plan#, Number of Watts/ ,`f� # Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 "4,1r.::744e4rtec Proposed <br /> OFFICE 322 TYPE A2 2 60t 120 <br /> OFFICE 314 TYPE A2 3 60i' 180 <br /> OFFICE 318 TYPE A2 2 60 'It i 120 <br /> -t44.*;*.W.1 <br /> CONF RM 315 TYPE A2 2 604410,r WV 120 <br /> j.OPEN OFFICE TYPE Al 14 30 r , s0 420 <br /> OFFICE 321 TYPE A2 2 60 ,_T " .{ ti 120 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1080 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> liohtino systems to demonstrate compliance.Refer to C502.1. j <br />
The URL can be used to link to this page
Your browser does not support the video tag.