Laserfiche WebLink
LEGEND <br /> REFER TO SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> REFER TO SHEET E506-1 FOR FIRE ALARM ABBREVIATIONS. <br /> 0.9 T <br /> 1 .5 T .5 T <br /> CI <br /> 0 <br /> FOR CONTINUATION, SEE SHEET 1E275 - I I I 1 <br /> HI II -- -- -- -- -- - - -- -- rt- -- - _ -I --1 -- -- -- -- GENERAL NOTES <br /> II SV255 N <br /> II it II - � 5 EPP/LTtD' o r <br /> �\\� EPPr LRDAL 0 ailII► 0 ° -EPP LRD a w <br /> �II II ! ! ,-21/uc Iv i/ , 22/10c �► I w <br /> 1 <br /> u On O O ` ��! o TYCO J- x S "1 I o _ <br /> �XCOBOX- — �:S J -_- el <br /> V <br /> 9 C 1/2"C, 22/0 1-1 4", 22/10C 1"C �� i"C PA 1"C, 4 ',' er 1/2"C, 41114 N <br /> 1/2"C, 4#1 DOWN TO TUNNEL 0 TO TUNNEL o <br /> r r <br /> II I— 6 Im d m 1 1¢ <br /> 2 <br /> II Z <br /> II 11 I 1"C Zo <br /> ' 0 3/4"C, 414 a REFERENCE DRAWINGS <br /> „ II II II 3/4"C, 4#14 / ,-0 <br /> III 'III IIII Tyco J-BOX © l <br /> ill <br /> r r ��RIBPt 1DEf€£fOR r T ir -- " ELEVATOR 64/65 FACP 0;t.l F nC0 J-BOXQ' 1 I <br /> I II I L-1/2"C, 61116 'LISP <br /> II II II `� �o oN. DETECTOR _: -m <br /> E ► F 1r7 <br /> II II III & I �O O; ' °E`2CTO{ �; NI"mimiEL °"'Rh ( `� CONSTRUCTION NOTES <br /> 11 I( 1) _O 0 >oW DET GTOR H N or �DISCONNECT AND REMOVE EXCESS PRESSURE PUMP <br /> II II II _ FA�Y7 _ s a { I SYSTEM AND APPURTENANCES. SEE 1/E506-TR FOR <br /> II I II • 4Q 1 - i 4 F EI T REMOVAL DETAIL. <br /> _ �_ Q I ELEVATOR <br /> ST R O }' I I N3F 1 - S tR REMOVE INTERNAL COMPONENTS FROM TYCO/ADT <br /> II ., ,, 1 N1S I �, I \ I N3S I r J-BOX. BOX TO REMAIN IN PLACE FOR REUSE. <br /> 11 II !—I 1F = ° oJI !-I a----p r--°=_I ,�i � r I I_I <br /> II <br /> 11 <br /> _ IL- I 1_ - 3�DISCONNECT AND REMOVE ORION XT DETECTION SYSTEM <br /> - -- - -- --- - IN ITS ENTIRETY PANEL, SAMPLING TUBES, FITTINGS <br /> BLDG. 40-026 AND APPURTENANCES). REMOVE CONDUIT AND <br /> CONDUCTORS BACK BACK TO FIRE ALARM CONTROL <br /> OPANEL. <br /> ®DISCONNECT AND REMOVE HORN STROBE, BACKBOX <br /> AND APPURTENANCES. REMOVE CONDUIT AND <br /> CONDUCTORS BACK TO SOURCE. PATCH AND PAINT <br /> WALL TO MATCH EXISTING CONDITIONS WHERE <br /> PARTIAL PLAN VIEW APPLICABLE. <br /> SCALE: 1/8"=1'-0" 0 REMOVE ORION BYPASS SWITCH AT ELEVATOR FIRE <br /> ALARM PANEL. ENGAGE ALEXANDER GOW FOR THIS <br /> WORK. ALEXANDER GOW IS THE SOLE CONTRACTOR FOR <br /> THIS WORK. <br /> ©REMOVE ABANDONED CONDUIT, CONDUCTORS, <br /> APPURTENANCES AND BOXES. REMOVE BACK TO J-BOX <br /> AS SHOWN. <br /> 7. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> PIPING MODIFICATIONS AS REQUIRED. <br /> 8. COORDINATE WITH BOEING SITE SERVICES FOR <br /> SURPLUS/DISPOSAL OF EQUIPMENT. <br /> V G o V 0 la <br /> � I BILOG 40+24 I <br /> oI <br /> �----1----1- -1----1---�—- -0 <br /> j[_1E260.-1E ---261-L1E262 IllE263 i 1E264 'I <br /> II 1 E265 11 E266 11 E267 11 E268 11 E269 !I lJJ Lo <br /> -4F-_* --I.-*-i-*--1-- --f--*--j,- L3 7 <br /> 111E270 11E271 11E272 11E273 11E274 I o <br /> II 1E275 1 1E276 11 E277 11 E278 1 1E279 I m <br /> 1 E280 r C 1 E281 1-1 E282 hE283 r 1 E284-I <br /> S A 2 A N - -_- -----fi-----,-----;---- --o <br /> u i i i i it <br /> GROUP BLDG 40-26 * DENOTES PLANS <br /> 600 Stewart St., Ste 1400 NOT INCLUDED IN <br /> KEY PLAN O THIS SET <br /> REM 0 VA L Seattle,Washington 98101 SCALE: NONE <br /> 4' 2' 0 4' 8' 12' 16' 20' <br /> ISSUE FOR CONSTRUCTION Tel 206.267.1700 <br /> MAY 30, 2018 Fax 206.267.1701 •• Elmo <br /> mom mom <br /> SAZAN#543-1744 <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> sYM REVISION BY A"PROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY LF 05.30.18 W2640474 A 05.30.18 <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/LF 05.30.18 - THIS DESIGN AND/OR LHECKEU FIRE ALARM SYSTEM PLAN-FIRST FLOOR <br /> SPECIFICATION IS APPROVED ZO 05.30.18 SHEET <br /> AISPO`,AW® APPROVED BY DEPT. DATE CK INE 05.30.18 TREE EVERETT FIRE PANEL REPLACEMENT 1 E280R <br /> CHECKEDD <br /> APPROVED CK <br /> 053018 BUILDING 40-025 JOB NO. COMP N0. <br /> APPRIWFn _._____.. .... DWG NO. <br />