My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-25 2020-10-22
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-25
>
3003 W CASINO RD BLDG 40-25 2020-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2020 10:13:04 AM
Creation date
1/25/2019 9:57:26 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-25
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br /> *SPRINKLER VALVE WATERFLOW ALARM LEGEND <br /> MONITORING AND WATERFLOW ISOLATION <br /> TO SPRINKLERS SUPERVISION EQUIPMENT INSTALLATION REFER TO SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> r WATERFLOW REFER TO SHEET E506-1 FOR FIRE ALARM ABBREVIATIONS. <br /> ,-� - - PRESSURE SWITCH I 0 <br /> WITH BUILT-IN <br /> RETARD/DELAY, I 5 GENERAL NOTES <br /> POTTER #WFSR-F <br /> (ALARM) I 12"X12" PHONE J-BOX <br /> �„ FACP EVT-FA-40-25 FOR PRIMARY AND 1. ELECTRICAL CONTRACTOR SHALL INSTALL ENCLOSURE(S) <br /> (BY FIRE ALARM VENDOR) SECONDARY PHONE PRIMARY CONNECTION:Q AND POWER. <br /> LINE JACKS PHONE LINE TO TELEPHONE <br /> (BY ELECTRICAL BACKBOARD/ DEMARC. 2. WET RISER/PIPING CONFIGURATION SHOWN IS <br /> CONTRACTOR) (CABLING BY BOEING IT) DIAGRAMMATIC AND DOES NOT NECESSARILY REPRESENT <br /> ANY SPECIFIC INSTALLATION. <br /> L— I TO WATER <br /> N — <br /> WATER PRESSURE GAUGE r __IMOTOR GONG <br /> (SYSTEM PRESSURE) / I I— — — — SECONDARY CONNECTION:Q7 <br /> ALARM LINE WATERFLOW PHONE LINE TO TELEPHONE <br /> t IISOLATION ISOLATION I BACKBOARD/DEMARC. <br /> ■ (OPEN) VALVE, -IA. TAMPER SWITCH, (CABLING BY BOEING IT) <br /> i-111P1-4E p 1 I APOLLO , POTTER #RBVS I <br /> BY-PASS LINE I ``i 194A-103-27 _ „' (SUPERVISORY) FIRE ALARM SYSTEM COMMUNICATIONS DETAIL M <br /> .:11 / SCALE: NONE E506-2 <br /> j Im <br /> CHECK VALVE /�.,„. II I RETARD REFERENCE DRAWINGS <br /> gI / �1`�!/\iiil z" CHAMBER <br /> WATER PRESSURE GAUGE ♦♦`` �j7 7 , A~\ CHECK I / DVA�lVE <br /> (SUPPLY PRESSURE) - OPEN • / i"� - J (CLOSED) <br /> i-i * p 0 <br /> OS&Y TAMPER % ►t4—1,11 i—rl <br /> ^ SWITCH WATER BY-PASS TEST <br /> (SUPERVISORY) STRAINER <br /> VALVE (CLOSED) <br /> IIIIII11i DRIP CONSTRUCTION NOTES <br /> 41 <br /> CUP 1 WORKMANLIKE WIRING <br /> SHALL BE MANNER. <br /> AND TRAINED IN A <br /> —� <br /> 2. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> OS&Y VALVE \ / 3. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> CONTROL (OPEN) 4. ALL PENETRATIONS TO ORE ALARM CONTROL PANEL AND <br /> CHECK TELECOMMUNICATIONS ENCLOSURES SHALL BE IN <br /> VALVE ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br /> PROVIDE PHENOLIC LABELS, INSTALL AND CENTER ON <br /> / DRAIN UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> WATER SUPPLY PIPE CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> LETTERING AND RED BACKGROUND. <br /> *NOTE: E>CONFIGURE FIRE ALARM CONTROL PANEL TO <br /> LIMIT OF ONE (1) ISOLATION PRIMARY AND SECONDARY COMMUNICATIONS INANSMfT VALVE ON ALARM SENSING LINE. SIMULTANEOUS MANNER IN ACCORDANCE WITH <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH W/DELAY DETAIL rThi <br /> NFPA72-2016 26.6.4.1.4(B)(7). <br /> SCALE: NONE E506-2 Ez>PROVIDE CONDUIT WITH PULLSTRING. COORDINATE ROUTING <br /> WITH BOEING IT. <br /> ®PROVIDE LINE SIZE BALL VALVE WITH LOCKABLE HANDLE, <br /> O TYPE AS NOTED, ON ALARM LINE UPSTREAM OF ALARM <br /> SWITCH <br /> 12>PROVIDE TAMPER SWITCH, TYPE AS NOTED, ON ISOLATION <br /> VALVE AS SHOWN. <br /> PROVIDE WATERFLOW PRESSURE SWITCH WITH ADJUSTABLE <br /> DELAY,TYPE AS NOTED. <br /> FIRE ALARM ANALOG PHONE LINE (PRIMARY)CONTROL PANEL 11. CONFIRM ONLY ONE (1) ISOLATION VALVE IS INSTALLED ON <br /> (FACP) *TELCO I WATERFLOW SENSING LINE. WHERE EXISTING INSTALLATIONS <br /> I DEMARC I -MONITORED BY TYCO AND HAVE MORE THAN ONE (1) VALVE, COORDINATE REMOVAL <br /> SIGNAL SENT TO CENTRAL OF ADDITIONAL VALVE(S) WITH BOEING CONSTRUCTION <br /> 1 I BOEING FIRE DEPARTMENT MANAGER. <br /> ANALOG PHONE LINE (SECONDARY) 12. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> -FIRE ALARM CABLING INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. <br /> O SMOKE DETECTOR, *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY <br /> PULL STATION, CODE,AS SHOWN. <br /> WATER FLOW & <br /> TAMPER SWITCHES *BOEING SERVICES REQUEST MUST BE MADE <br /> REQUESTING: TWO ANALOG VOICE (BUSINESS FLAT LINE) <br /> rpnei HORNS, BELLS JACK/CONNECTIONS. AFTER JACKS ARE INSTALLED, <br /> &STROBES ANALOG LINES MUST BE REQUESTED TO CONNECT <br /> ANALOG VOICE JACKS. <br /> SAZA" N <br /> GROUP <br /> FIRE ALARM SYSTEM SIGNAL AND COMMUNICATIONS OVERVIEW n 600StewartSt., Ste1400 <br /> SCALE: NONE E506-2 Seattle,Washington 98101 <br /> ISSUE FOR CONSTRUCTION Tel 206.267.1700 <br /> MAY 30, 2018 W Fax 206.267.1701 <br /> SAZAN#543-1744 <br /> SYM REVISION BY APPROVED DATE GYM REVISION BY APPROVED DATE <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY ER 08.25.91 FIRE ALARM SYSTEM DETAILS <br /> A EVERETT FIRE PANEL REPLACEMENT •W2640474 SAZAN/LF 05.30.18 THIS DESIGN AND/OR MMSD 08.28.91 W2640474 A 05.30.18 <br /> SPECIEGTION IS APPROVED ENCINCER TfTLE EVERETT FIRE PANEL REPLACEMENT _SHEET <br /> el.- <br /> ArAW,AW® APPROVED BY DEPT. DATE �D 08.31.91 E506-2 <br /> CHECKED <br /> WJP 0391 BUILDING 40-025 <br /> APPROVED JOB NO. COMP NO. <br /> WJP 09.06.91 <br /> APPRnOin _.____._._ DWG NO. <br />
The URL can be used to link to this page
Your browser does not support the video tag.