• <br /> LEGEND <br /> REFER TO SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> REFER TO SHEET E506-1 FOR FIRE ALARM ABBREVIATIONS. <br /> SIGN, TO READ: 480V ELEVATOR POWER <br /> ELEVATOR CONTROL <br /> ONLY- DO NOT TEST" DISCONNECT SWITCH <br /> MACHINE ROOM ROOF SHUNT TRIP UNIT <br /> 135'F HEAT DETECTOR 0 N p 212°F AUTOMATIC G.E. CAT. N0. <br /> LOCATE WITHIN 18" T=/ <br /> OF SPRINKLER HEAD #14 SPRINKLER BY MECH. TEDST12-RS OR <br /> EQUAL <br /> ELEVATOR <br /> �T- a C.B. —CONTROL <br /> SHUNT TRIP CIRCUIT PANEL FUSE FNQ-4/10 <br /> CATWALK LEV <br /> BREAKER ��014 MACHINE ROOM FLOOR FUSE AGC-1.25 <br /> to BUSSMANN OR EQUAL GENERAL NOTES <br /> TO ELEVATOR © 135' F HEAT <br /> POWER 212°F AUTOMATIC DETECTORS 1. LOCATE SIGN ADJACENT TO BELL. SIGN TO READ <br /> SPRINKLER BY MECH. "ELEVATOR FIRE ALARM NOTIFY FIRE DEPARTMENT <br /> 135°F HEAT DETECTOR LOCATED 342-2222". SIGN TO BE PLASTIC LAMINATED <br /> WITHIN 18" OF EACH SPRINKLER HEAD / WITH RED BACKGROUND AND 1" HIGH WHITE <br /> SIGN TO READ "ELEVATOR CONTROL <br /> ONLY-DO NOT TEST" ) BLOCK LETTERS. <br /> 5TH FLOOR �� III 2. FOR FIRE DETECTION PLANS SEE SHTS. E554, <br /> \II E557, AND E558. <br /> c'''' 1/2"C, 8#14 ® 3. PROVIDE CONTROL TRANSFORMER 150VA 480/240-120V <br /> WITH FUSED PRIMARY AND SECONDARY IN NEMA 1 <br /> NOTE 3 HINGED ENCLOSURE 10"x8"x6". SQ"D" CLASS <br /> S© 9070 K150D1. <br /> II <br /> 3/4"C,12#14 CIRCUIT BREAKER REFERENCE DRAWINGS <br /> 4TH FLOOR TO ELEVATOR CONTROLLER <br /> O ELEVATOR POWER DISCONNECT <br /> 3/4"C, 16#14 WIRING DIAGRAM <br /> SCALE: NONE <br /> 3RD FLOOR CONSTRUCTION NOTES <br /> O <br /> 1"C, 20#14 <br /> 2ND FLOOR <br /> 1"C,24#14 <br /> SIGN, SEE NOTE #1 <br /> TO ELEVATOR <br /> CONTROLLER <br /> 1/2"C,4#14--,,, <br /> 1/2"C,4#14 #14 / TO1/2°C BUILDING FIRE ALARM CONTROL PANEL <br /> 6#16 <br /> 1- �—TO EMER. CKT. <br /> 1/2"C,8#14 4 <br /> 1ST FLOOR <br /> FIRE ALARM CONTROL PANEL <br /> TUNNEL - FIRE FIGHTERS <br /> CONTROL STATION <br /> 0 SPRINKLER HEAD BY MECH. <br /> ELEVATOR PIT <br /> ELEVATOR 57 AND 54 <br /> FIRE DETECTION RISER DIAGRAM S 2 A N <br /> SCALE: NTS <br /> GROUP <br /> 600 Stewart St., Ste 1400 <br /> Seattle,Washington 98101 <br /> FOR REFERENCE ONLY ISSUE FOR CONSTRUCTION 0 Tel 206.267.1700 <br /> MAY 30,2018 Fax 206.267.1701 <br /> i- SAZAN#543-1744 <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL SYM REVATGN BY APPROVED DATE SYM R&MON BY APPROVED DATE ACCEPTABILITY MS 08-25-91 ELEVATOR FIRE DETECTION RISER <br /> RECORD DRAWING ISSUED TO OWNER HAS JRB 5-31-94 THIS DESIGN AND/OR CHECKED W2640474 A DATE <br /> 05.30.18 <br /> elcc SPECIFICATION IS APPROVED EVER 08-28-91 DIAGRAM-ELEV 57&54 SHEET <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SA2AN/LF 05.30.18 �O`,��® APPROVED BY DEPT. DATE LADNEEH 08-31-91 TITLE EVERETT FIRE PANEL REPLACEMENT E566 <br /> CHECKED <br /> WJP 09-03-91 BUILDING 40-025 <br /> APPROVED JOB NO. COMP NO. <br /> WJP 09-06-91 <br /> APPROVFO _.____._.. ____ DWG ND. <br />