Laserfiche WebLink
SIGN, TO READ: <br /> "ELEVATOR CONTROL ONLY- DO NOT TEST" LEGEND <br /> MACHINE ROOM ROOF REFER TO SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> 135'F HEAT DETECTOR LOCATE WITHIN 18" S O 212'F AUTOMATIC SPRINKLER REFER TO SHEET E506-1 FOR FIRE ALARM ABBREVIATIONS. <br /> H OF EACH SPRINKLER #14 BY MECH. (TYP) <br /> HEAD (TYP) + ELEVATOR <br /> a C.B. —CONTROL <br /> PANEL <br /> ❑' °#14 #14 <br /> MACHINE ROOM FLOOR <br /> TO ELEVATOR POWER © 12152 F AUTOMATIC <br /> SHUNT TRIP < SPRINKLER BY MECTH. <br /> CIRCUIT BREAKER WITHIN 18" FEEACH RINKLED 480V ELEVATOR POWER <br /> 18"OF EACH SPRINKLER HEAD <br /> SIGN TO READ "ELEVATOR CONTROL <br /> ONLY-DO NOT TEST" DISCONNECT SWITCH GENERAL NOTES <br /> ROOF LEVEL SHUNT TRIP UNIT G.E. <br /> SIGN,TO READ: "ELEVATOR CONTROL CAT. NO. TEDSTI2-RS 1. FOR FIRE DETECTION PLAN SEE SHT E562 AND E563. <br /> ONLY- DO NOT TEST" OR EQUAL 2. LOCATE SIGN ADJACENT TO BELL. SIGN TO READ <br /> SHUNT TRIP CIRCUIT BREAKER FUSE FNQ-4/10 "ELEVATOR FIRE ALARM NOTIFY FIRE DEPARTMENT <br /> FA SO 342-2222"SIGN TO BE PLASTIC LAMINATED WITH <br /> RED BACKGROUND AND 1" HIGH BLOCK LETTERS. <br /> TO ELEVATOR POWER g O FUSE AGC-1.25 <br /> #14 BUSSMANN OR EQUAL <br /> 135' F HEAT 3. PROVIDE CONTROL TRANSFORMER 150VA 480/240 120V <br /> HINGED ENCLOSURE 10"x8"x6". SQ"D" CLASS <br /> NN <br /> WITH FUSED PRIMARY AND SECONDARY IN NEMA 1 <br /> ELEVATOR <br /> C.B. —CONTROL 1/2"C 8#14 DETECTORS <br /> PANEL <br /> s A <br /> 9070 K150D1. <br /> 0#141 <br /> CATWALK LEVEL <br /> '� <br /> m REFERENCE DRAWINGS <br /> - 3/4"C,16#14 <br /> NOTE 3 <br /> 6 <br /> 5TH FLOOR <br /> CIRCUIT BREAKER <br /> .0 TO ELEVATOR CONTROLLER <br /> 3/4"c,20#14 CONSTRUCTION NOTES <br /> ELEVATOR POWER DISCONNECT <br /> 4TH FLOOR WIRING DIAGRAM <br /> SCALE: NONE <br /> 0 <br /> • 1"C, 24#14 <br /> L <br /> 3RD FLOOR <br /> `U a14 FA 0 <br /> • 1"C, 32#14 <br /> 2ND FLOOR <br /> 1 1/4"C,36#14 <br /> TO ELEVATOR SIGN, SEE NOTE 2 <br /> CONTROLLER <br /> 1/2"C,4#14 <br /> 14 1/2"C,4#14 FA #14 TO BUILDING FIRE ALARM CONTROL PANEL <br /> /'CCC <br /> #14 1/2"C,8#14J �TO EMER. CKT. <br /> #14, V <br /> 1ST FLOOR <br /> Q6 FA Q <br /> TUNNEL #14 FIRE ALARM CONTROL PANEL ^'` <br /> FIRE S A 2 A I J <br /> CONTROLOL STATION <br /> ION <br /> GROUP <br /> O SPRINKLER HEAD BY MECH. <br /> ELEVATOR PIT 600 Stewart St., Ste 1400 <br /> FOR REFERENCE ONLY Seattle,Washington <br /> .26 .1701 <br /> ELEVATOR 62/63 FIRE DETECTION RISER DIAGRAM ISSUE FOR CONSTRUCTION 0 Tel 206267.1700 <br /> SCALE: NONE MAY 30, 2018 Fax 206.267.1701 <br /> SAZAN#543-1744 <br /> DRAWN DATA SUBERLE CURRENT REVISION SYMBOL DALE <br /> SYM REVISION BY APPROVED 31E SYM- REVISOR BY APPROVED DATE ACCEPTABILITY CDR I08-25-91 ELEVATOR FIRE DETECTION RISER DIAGRAM-ELEV 63 W2640474 A 05.30.18 <br /> RECORD DRAWING ISSUED TO OWNER HAS JRB 5-31-94 THIS DESIGN AND/OR ZALUKEO <br /> SPECIFlCATION IS APPROVED MMS 08-28-91 SHEET C�7 <br /> A EVEREIT FIRE PANEL REPLACEMENT W2640474 SAZAN/LF 05.30.18 ® APPROVED BY DEPT. DATE UDNEER 08-31-91 � EVERETT FIRE PANEL REPLACEMENT E5 f O <br /> giAirLIVEFAW CHECKED <br /> DK BEC 9/06/91 WJp 09-03-91 BUILDING 40-025 JOB NO. COMPi: <br /> APPROVED1P 09-06-91 <br /> AORRNIFD _.____._ ____ -.___ DWG NO. <br />