My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
>
Address Records
>
COLBY AVE
>
1321
>
VERIZON WIRELESS ANTENNAS
>
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2019 3:16:00 PM
Creation date
1/25/2019 3:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
VERIZON WIRELESS ANTENNAS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seismic Load Calculation for Components and System <br /> (Reference: IBC 2015 Section 1613&ASCE 7-10 Section 13.3) <br /> Seismic Force: <br /> 0.2s Spectral Response Acceleration,Site Class B,S, = 1.281 (ASCE 7,Figure 22-1 thru 22-6) <br /> 1.0s Spectral Response Acceleration,Site Class B,S1 = 0.487 (ASCE 7,Figure 22-1 thru 22-6) <br /> Site Class = D (ASCE 7,Section 11.4.2) <br /> Seismic Design Category = D (ASCE 7,Tables 11.6-1&11.6-2) <br /> Site Coefficient per Ss&Site Class,F. = 1.00 (ASCE 7,Table 11.4-1) <br /> Site Coefficient per St&Site Class,FY = 1.51 (ASCE 7,Table 11.4-2) <br /> SMS=F.S. = 1.281 (ASCE 7,Section 11.4.3) <br /> SMS=FYSS = 0.735 (ASCE 7,Section 11.4.3) <br /> SDS=2/3 SMS = 0.854 (ASCE 7,Section 11.4.4) <br /> S51=2/3 Sµ1 = 0.490 (ASCE 7,Section 11.4.4) <br /> (Per ASCE 7-10,13.3) <br /> Component Amplification Factor,a1, = 1.0 (ASCE 7,Table 13.6-1) <br /> Component Response Modification Factor,Ftp = 2.5 (ASCE 7,Table 13.6-1) <br /> Component importance Factor,Ip = 1.0 (ASCE 7,Table 1.5-2) <br /> Component Operating Weight,Wp = Wp (ib) <br /> Height in structure at lowest point of attachment of component,zl = 116 (ft) <br /> Height in structure at highest point of attachment of component,z2 = 116 (ft) <br /> Average Roof Height of Structure,h = 112 (ft) <br /> Seismic design force,Fp = 0.4sI1SDSWp (1+2z/h) <br /> ltp/Ip (Eq.13.3-1) <br /> Max.seismic design force,F = 1.6SOSIPWp (Eq.13.3-2) <br /> Min.seismic design force,Fr„JD = 0.3SDSIPWp (Eq.13.3-3) <br /> Seismic design force at lowest point,Fin = 0.420 Wp <br /> FP IAvm= 0.420 <br /> Seismic design force at highest point,Fp2 = 0.420 Wp <br /> Min.seismic design force,F.... = 0.256 Wp <br /> Max.seismic design force,F,,,,,, = 1.366 Wp <br /> Seismic design force,Fp(ASD) = 0.300 Wp <br /> Desaipdon BY Data <br /> G NAL 11/13/2017 <br /> ENGINEERING Checked ono <br /> Seismic Loads For Components&Systems <br /> ProJatt Seale Sheet No. <br /> N.T.S. <br /> 250 4th Ave.South SEA DT Everett <br /> Suite 200 lob No. 5 I <br /> Edmonds,WA 98020 17015.270 <br /> ( <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.