My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
>
Address Records
>
COLBY AVE
>
1321
>
VERIZON WIRELESS ANTENNAS
>
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2019 3:16:00 PM
Creation date
1/25/2019 3:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
VERIZON WIRELESS ANTENNAS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Title Block Line 1 Project Title: <br /> . - You can change this area Engineer: Project ID: <br /> using the"Settings"menu item Project Descr: <br /> and then using the"Printing& <br /> . Title Block"selection. <br /> Title Block Line 6 Printed:15NOV 2017,3:43PM <br /> Concrete Beam ;Projects11zon\ <br /> 7015 Camp&Associates1200 Veri270 SEA DT Everettl_Stmcturat\Engineeringlpenthouse roof.ec6 1 <br /> ENERCALC,INC.1983-2017,Build:10.17.8.29,Ver:10.17.8.29 <br /> Lic.#: r-060r - ,.-._ Licensee,;CG 1G1 -_ ;Me <br /> Description: existing slab <br /> CODE REFERENCES <br /> Calculations per ACI 318-14, IBC 2015,ASCE 7-10 <br /> Load Combination Set: IBC 2015 <br /> Material Properties <br /> fc = 4.0 ksi 6 Phi Values Flexure: 0.90 <br /> fr= fc1/2 *7.50 = 474.342 psi Shear: 0.750 <br /> y7 Density = 150.0 pcf R 1 = 0.850 <br /> X LtWt Factor = 1.0 <br /> Elastic Modulus = 3,122.0 ksi Fy-Stirrups 40.0 ksi <br /> fy-Main Rebar = 60.0 ksi E-Stirrups = 29,000.0 ksi <br /> E-Main Rebar = 29,000.0 ksi Stirrup Bar Size# 3 <br /> Number of Resisting Legs Per Stirrup= 2 <br /> s- l <br /> S(0.0330) 90.0261) .5-W0432641 ,y <br /> 1e" v-c-4"I i +-_ -_ --_ 18 8.830 ft• 8.830 ft <br /> Cross Section &Reinforcing Details <br /> Rectangular Section, Width=16.0 in, Height=4.0 in <br /> Span#1 Reinforcing.... <br /> 1-#4 at 1.80 in from Top,from 0.0 to 13.0 ft in this span <br /> Span#2 Reinforcing.... <br /> 144 at 1.80 in from Top,from 0.0 to 10.0 ft in this span <br /> Span#3 Reinforcing.... <br /> 1-#4 at 1.80 in from Top,from 0.0 to 10.0 ft in this span <br /> Applied Loads Service loads entered.Load Factors will be applied for calculations. <br /> Beam self weight calculated and added to loads <br /> L <br /> Loads on all spans... <br /> S=0.0330 /A . . !; ., ♦ - f' <br /> Uniform Load on ALL spans: S=0.0330 k/ft <br /> Load for Span Number 2 n 1 'j. '" r`..i ••: 1 t <br /> Uniform Load: D=0.02510 k/ft,Extent=2.830->>8.830 ft, Tributary Width=1.0 ft <br /> Load for Span Number 3 <br /> Uniform Load: D=0.02510 k/ft,Extent=0.0-->>6.0 ft, Tributary Width=1.0 ft <br /> DESIGN SUMMARY Design N.G. i <br /> Maximum Bending Stress Ratio = 0.939 : 1 Maximum Deflection <br /> Section used for this span Typical Section Max Downward Transient Deflection 0.014 in Ratio= 10028>=36 <br /> Mu:Applied -1.765 k-ft Max Upward Transient Deflection 0.000 in Ratio= 0<360 <br /> Mn*Phi:Allowable 1.881 k-ft Max Downward Total Deflection 0.042 in Ratio= 3434>=18 '. <br /> Max Upward Total Deflection -0.001 in Ratio= 72307>=18 <br /> Location of maximum on span 0.000 ft <br /> Span#where maximum occurs Span#1 <br /> Vertical Reactions Support notation:Far left is#1 <br /> Load Combination Support 1 Support 2 Support 3 Support 4 <br /> Overall MAXimum 0.629 1.100 1.040 0.498 <br /> Overall MINimum 0.210 0.350 0.271 0.151 <br /> +D+H 0.419 0.750 0.768 0.348 <br /> +D+L+H 0.419 0.750 0.768 0.348 71 <br />
The URL can be used to link to this page
Your browser does not support the video tag.