My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
>
Address Records
>
COLBY AVE
>
1321
>
VERIZON WIRELESS ANTENNAS
>
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2019 3:16:00 PM
Creation date
1/25/2019 3:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
VERIZON WIRELESS ANTENNAS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Title Block Line 1 Project Title: <br /> • You can change this area Engineer: Project ID: <br /> using the"Settings"menu item Project Descr: <br /> and then using the"Printing& <br /> Title Block"selection. <br /> Title Block Line 6 Printed:15NOV 2017,2:55Pld <br /> Concrete Beam s Projects\17015 Camp&Associates1200 Verizon1270 SEA DT Everett\_StruclurallEngineering\penthouse roof.ec6 <br /> ENERCALC,INC.1983-2017,Build:10.17.8.29,Ver:10.17.8.29 <br /> Lic.#: KW-06005155 Licensee:CG ENGINEERING <br /> Description: exist beam <br /> CODE REFERENCES <br /> Calculations per ACI 318-14, IBC 2015,ASCE 7-10 <br /> Load Combination Set : IBC 2015 <br /> Material Properties <br /> fc = 4.0 ksi d) Phi Values Flexure: 0.90 <br /> fr= fc112 * 7.50 = 474.342 psi Shear: 0.750 <br /> yf Density = 150.0 pcf 131 = 0.850 <br /> ?� LtWt Factor = 1.0 <br /> Elastic Modulus = 3,122.0 ksi Fy-Stirrups 40.0 ksi <br /> fy Main Rebar = 60.0 ksi E-Stirrups = 29,000.0 ksi <br /> E-Main Rebar = 29,000.0 ksi Stirrup Bar Size# 3 <br /> Number of Resisting Legs Per Stirrup= 2 <br /> • . . <br /> 0> D(0.915) <br /> D 0 6880 S 0.290 <br /> • <br /> •i \ <br /> 0> 12-250 ft 21.420 ft <br /> l4"-w-x2O.,..ti - - --- --14"w c20"h <br /> I <br /> Cross Section & Reinforcing Details _ <br /> Rectangular Section, Width=14.0 in, Height=20.0 in <br /> Span#1 Reinforcing.... <br /> 345 at 3.0 in from Bottom,from 0.0 to 12.250 ft in this span <br /> Span#2 Reinforcing.... <br /> 345 at 3.0 in from Bottom,from 0.0 to 21.420 ft in this span <br /> Applied Loads Service loads entered.Load Factors will be applied for calculations. <br /> Beam self weight calculated and added to loads <br /> Loads on all spans... <br /> D=0.6880, S=0.2290 <br /> Uniform Load on ALL spans: D=0.6880, S=0.2290 k/ft <br /> Load for Span Number 1 <br /> Uniform Load: D=0.0760 k/ft,Extent=2.250-->>12.250 ft, Tributary Width=1.0 ft <br /> Load for Span Number 2 <br /> Uniform Load: D=0.0760 k/ft,Extent=0.0--»2.0 ft, Tributary Width=1.0 ft <br /> Point Load: D=0.9150 k aA 18.0 ft <br /> DESIGN SUMMARY Design N.G. <br /> Maximum Bending Stress Ratio = 0.490 : 1 Maximum Deflection <br /> Section used for this span Typical Section Max Downward Transient Deflection 0.009 in Ratio= 27629>=36 <br /> Mu:Applied 33.629 k-ft Max Upward Transient Deflection 0.000 in Ratio= 0<360 <br /> Mn`Phi:Allowable 68.692 k-ft Max Downward Total Deflection 0.061 in Ratio= 4237>=18 <br /> Max Upward Total Deflection -0.005 in Ratio= 30741>=18 <br /> Location of maximum on span 10.142 ft <br /> Span#where maximum occurs Span#2 <br /> Vertical Reactions Support notation:Far left is#1 <br /> Load Combination Support 1 Support 2 Support 3 <br /> Overall MAXimum 4.866 23.744 13.913 <br /> Overall MINimum 0.944 4.164 2.603 <br /> +0+H 4.289 18.661 11.863 <br /> +D+L+H 4.289 18.661 11.863 <br /> +D+Lr+H 4.289 18.661 11.863 �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.