My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
>
Address Records
>
COLBY AVE
>
1321
>
VERIZON WIRELESS ANTENNAS
>
1321 COLBY AVE VERIZON WIRELESS ANTENNAS 2019-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2019 3:16:00 PM
Creation date
1/25/2019 3:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
VERIZON WIRELESS ANTENNAS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES. <br /> 1. INSERT SCISSOR BRACKETS BETWEEN THE UPPER DIPLEXER NOTE. <br /> 0 0 ANTENNA MOUNTING BRACKET AND THE UPPER 1, DIPLEXERS CAN BE MOUNTED TO x T4';,:f <br /> • POLE ADAPTER BRACKET. SECURE USING 1/2 PIPE, WALL OR UNISTRUT. r 11f/// <br /> / MOUNTING PIPE '!:'' '1:::: <br /> a' zly"a <br /> GENERAL NOTES: 0 0 O '� INCH HARDWARE PROVIDED. 2. CONTRACTOR TO VERIFY WITH <br /> .� <br /> 2. TO SET THE DEGREE OF DOWNTILT, ALIGN THE <br /> MANUFACTURER SPEC's FOR <br /> 1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, 0 DESIRED HOLES ON THE SCISSOR BRACKETS AND ATTACH PER MOUNTING DETAILS. <br /> .t.*a.M1,.4444',' ry <br /> REGULATIONS AND SAFETY REGULATIONS,ALL OSHA REGULATIONS, ALL PUBLIC AND SECURE USING 5/16 INCH HARDWARE PROVIDED, MANUFACTURER 3. DIPLEXER DETAIL AS SHOWN AS A <br /> MUNICIPAL AUTHORITIES,AND ANY UTIUTY COMPANIES' REGULATIONS AND DIRECTIVES. 11110404td 3. THE NUMBER OF CONNECTORS WILL VARY BASED RECOMMENDATIONS REFERENCE AND IS SUBJECT TOy�=1 © ON ANTENNA ttPE ) ' MANUFACTURER PROVIDED CHANGE. 'I , `"2. THE DRAWINGS AND SPECIFICATIONS AREA GENERAL DIRECTIVE FOR THE SCOPE OF Li%. �I OPTIONAL DOWNTILT \ BRACKET14 <br /> WORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR , �5;- WEIGHT: �' <br /> IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL �` BRACKET vi��yii 6 LBS . <br /> DISCREPANCIES TO REPRESENTATIVE.ANY MINOR ERRORS AND OMISSIONS IN THE 41jIII ` <br /> 1111111111 <br /> DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM COMPLETING III <br /> 0 PIPE MOUNT (TYP) I 1� Ler <br /> THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE VALMONT MICROFLECT '711 <br /> xI a <br /> DOCUMENTS. PART#B1001 OR / 6.22" / I 6.77" <br /> 3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF <br /> APPROVED EQUAL ( DIPLEXER (TYPICAL) <br /> CABLE TRAYS AND ELECTRICAL UNES AND ANTENNA MOUNTING. <br /> I/ PANEL ANTENNA(TYP) <br /> C C Olt-II <br /> 4. VERIFICATION THAT EXISTING TOWER POLE CAN SUPPORT THE PROPOSED ANTENNA, O Or/ O <br /> COAX &ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. - II 1 <br /> PARTS: OIPI FXFR NOTF' \ <br /> .I AUJI <br /> ITEM QTY DESCRIPTION 1. DIPLEXERS MOUNTED AT ANTENNAS. G`) N II HILL <br /> 1` © 0 1 ADAPTER, POLE, LOWER 2. CONTRACTOR TO VERIFY WITH O11.111111111111M1 <br /> u �"i SAGE <br /> � 0'nor' SPEC's FOR MOUNTING �\ �'i�_ I� <br /> 1 BRACKET, DOWNTILT, POLE (; ® :i ®� Ih'II ¢f'0�55510Dd1 SEPVICE5 <br /> 0 DETAILS. - •l:!• 1 <br /> 0 p I BRACKET, DOWNTILT, ANTENNA 3. DIPLEXER DETAIL AS SHOWN AS A l O 1 O <br /> 0 6 1/2 X 1 HEX HEAD BOLT P. REFERENCE AND IS SUBJECT TO CHANGE. ,(0)]¢ Illi <br /> E7 6 1/2 SPLIT WASHER 4. MOUNTING SHOWN AS TYPICAL. VERIFY �e� I'�o. I SEA <br /> 0 O 2 5/16 X 1 HEX HEAD BOLT ACTUAL CONDITIONS IN FIELD. <br /> m CO 0 2 5/16 SPUT WASHER DT EVERETT <br /> O 4 1/2" THREADED ROD <br /> 65 4.3-10 FEMALE <br /> O 8 1/2" SPLIT WASHER <br /> O 12 1/2" NUT (AWS) <br /> GENERAL NOTES 2 ANTENNA MOUNTING HARDWARE 3 DIPLEXER MOUNTING DETAIL 4 JMA DBC-67-C-2SF DIPLEXER <br /> 1 <br /> 1321 COLBY AVE <br /> NOT TO SCALE NOT TO SCALE NOT TO SCALE EVERETT,WA 98201 <br /> RRUS NOTES: <br /> 1. RRUS MOUNTED NEAR ANTENNAS. OC <br /> NOTES: 2. CONTRACTOR TO VERIFY WITH <br /> 1) MOUNTING HARDWARE INCLUDED WITH UNIT MANUFACTURER SPEC's FOR MOUNTING <br /> (REUSE FROM SXK 125 0245/1) DETAILS. <br /> 2) EQUIPMENT INFORMATION OBTAINED FROM 3. RRUS DETAIL AS SHOWN AS A REFERENCE <br /> MANUFACTURERS PRODUCT DATA SHEET, SUBJECT AND IS SUBJECT TO CHANGE. /� <br /> TO CHANGE. CONTRACTOR TO VERIFY. 4. MOUNTING SHOWN AS TYPICAL. VERIFY CAMP'S" <br /> ACTUAL CONDITIONS IN FIELD. <br /> 5. TO ENSURE ADEQUATE AIRFLOW BETWEEN UNITS ASSOCIATES <br /> ALLOW A MINIMUM OF 1534" FREE SPACE <br /> BETWEEN RRUS INSTALLED VERTICALLY ON A 40TH <br /> 19401AVE.W.,SUITE 304 <br /> POLE. ALLOW A MIN. OF 18W' BETWEEN RRUS 01 OD,WA 98036 <br /> RRUS-32 PER PLA11111i , AND ANTENNA, IF INSTALLED ABOVE OR BELOW PHONE:(425)740-6392 <br /> FAX:(425)224-1614 <br /> � NOTE: WEIGHT OF UNIT <br /> RRUS INSTALLED SIDEI BYUMY SIDE. THE MINIMOF 77/8" BETWEEN WWW.CAMPASSOC.COM <br /> 1 1111 <br /> IS 51 LBS (VERIFY) DISTANCE FROM THE BOTTOM OF THE RRUS TO <br /> THE FLOOR IS 113'x" PROJECT MANAGER: EJC <br /> PREPARED BY: JOT/EAT <br /> Il APPROVED BY: EJC <br /> MOUNTING PIPE <br /> 12.06" EAT 11/22/17 ISSUE0 FOR PERMIT <br /> EAT 11/3/17 ISSUED FOR PRELIM REVIEW <br /> PLAN REVIEWERS SIGNATURE <br /> .-■ MOUNTING PIPE Ill= <br /> MOUNTING HARDWARE <br /> INCLUDED <br /> OK <br /> LSmmi-itilV <br /> I ,,,„,,,,,,, , <br /> II <br /> REMOTE RADIO V J <br /> UNIT (RRUS-32) m ...ill RADIO / a <br /> UNIT(RRU-32) <nv t On \ C <br /> C / , • li 1 C <br /> cia -sr <br /> NAN <br /> ipi - <br /> 14 HEFT NA,- <br /> N1111111r DETAILS <br /> I I <br /> SIDE FRONT <br /> SHEET NUMBER <br /> A-4 <br /> RRUS-32 MOUNTING DETAIL NOT USED PROJECT NUMBER 7 <br /> 20171559411 ? , <br /> 5 NOT TO SCALE NOT TO SCALE <br />
The URL can be used to link to this page
Your browser does not support the video tag.