Laserfiche WebLink
NOTES. <br /> 1. INSERT SCISSOR BRACKETS BETWEEN THE UPPER DIPLEXER NOTE. <br /> 0 0 ANTENNA MOUNTING BRACKET AND THE UPPER 1, DIPLEXERS CAN BE MOUNTED TO x T4';,:f <br /> • POLE ADAPTER BRACKET. SECURE USING 1/2 PIPE, WALL OR UNISTRUT. r 11f/// <br /> / MOUNTING PIPE '!:'' '1:::: <br /> a' zly"a <br /> GENERAL NOTES: 0 0 O '� INCH HARDWARE PROVIDED. 2. CONTRACTOR TO VERIFY WITH <br /> .� <br /> 2. TO SET THE DEGREE OF DOWNTILT, ALIGN THE <br /> MANUFACTURER SPEC's FOR <br /> 1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, 0 DESIRED HOLES ON THE SCISSOR BRACKETS AND ATTACH PER MOUNTING DETAILS. <br /> .t.*a.M1,.4444',' ry <br /> REGULATIONS AND SAFETY REGULATIONS,ALL OSHA REGULATIONS, ALL PUBLIC AND SECURE USING 5/16 INCH HARDWARE PROVIDED, MANUFACTURER 3. DIPLEXER DETAIL AS SHOWN AS A <br /> MUNICIPAL AUTHORITIES,AND ANY UTIUTY COMPANIES' REGULATIONS AND DIRECTIVES. 11110404td 3. THE NUMBER OF CONNECTORS WILL VARY BASED RECOMMENDATIONS REFERENCE AND IS SUBJECT TOy�=1 © ON ANTENNA ttPE ) ' MANUFACTURER PROVIDED CHANGE. 'I , `"2. THE DRAWINGS AND SPECIFICATIONS AREA GENERAL DIRECTIVE FOR THE SCOPE OF Li%. �I OPTIONAL DOWNTILT \ BRACKET14 <br /> WORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR , �5;- WEIGHT: �' <br /> IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL �` BRACKET vi��yii 6 LBS . <br /> DISCREPANCIES TO REPRESENTATIVE.ANY MINOR ERRORS AND OMISSIONS IN THE 41jIII ` <br /> 1111111111 <br /> DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM COMPLETING III <br /> 0 PIPE MOUNT (TYP) I 1� Ler <br /> THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE VALMONT MICROFLECT '711 <br /> xI a <br /> DOCUMENTS. PART#B1001 OR / 6.22" / I 6.77" <br /> 3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF <br /> APPROVED EQUAL ( DIPLEXER (TYPICAL) <br /> CABLE TRAYS AND ELECTRICAL UNES AND ANTENNA MOUNTING. <br /> I/ PANEL ANTENNA(TYP) <br /> C C Olt-II <br /> 4. VERIFICATION THAT EXISTING TOWER POLE CAN SUPPORT THE PROPOSED ANTENNA, O Or/ O <br /> COAX &ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. - II 1 <br /> PARTS: OIPI FXFR NOTF' \ <br /> .I AUJI <br /> ITEM QTY DESCRIPTION 1. DIPLEXERS MOUNTED AT ANTENNAS. G`) N II HILL <br /> 1` © 0 1 ADAPTER, POLE, LOWER 2. CONTRACTOR TO VERIFY WITH O11.111111111111M1 <br /> u �"i SAGE <br /> � 0'nor' SPEC's FOR MOUNTING �\ �'i�_ I� <br /> 1 BRACKET, DOWNTILT, POLE (; ® :i ®� Ih'II ¢f'0�55510Dd1 SEPVICE5 <br /> 0 DETAILS. - •l:!• 1 <br /> 0 p I BRACKET, DOWNTILT, ANTENNA 3. DIPLEXER DETAIL AS SHOWN AS A l O 1 O <br /> 0 6 1/2 X 1 HEX HEAD BOLT P. REFERENCE AND IS SUBJECT TO CHANGE. ,(0)]¢ Illi <br /> E7 6 1/2 SPLIT WASHER 4. MOUNTING SHOWN AS TYPICAL. VERIFY �e� I'�o. I SEA <br /> 0 O 2 5/16 X 1 HEX HEAD BOLT ACTUAL CONDITIONS IN FIELD. <br /> m CO 0 2 5/16 SPUT WASHER DT EVERETT <br /> O 4 1/2" THREADED ROD <br /> 65 4.3-10 FEMALE <br /> O 8 1/2" SPLIT WASHER <br /> O 12 1/2" NUT (AWS) <br /> GENERAL NOTES 2 ANTENNA MOUNTING HARDWARE 3 DIPLEXER MOUNTING DETAIL 4 JMA DBC-67-C-2SF DIPLEXER <br /> 1 <br /> 1321 COLBY AVE <br /> NOT TO SCALE NOT TO SCALE NOT TO SCALE EVERETT,WA 98201 <br /> RRUS NOTES: <br /> 1. RRUS MOUNTED NEAR ANTENNAS. OC <br /> NOTES: 2. CONTRACTOR TO VERIFY WITH <br /> 1) MOUNTING HARDWARE INCLUDED WITH UNIT MANUFACTURER SPEC's FOR MOUNTING <br /> (REUSE FROM SXK 125 0245/1) DETAILS. <br /> 2) EQUIPMENT INFORMATION OBTAINED FROM 3. RRUS DETAIL AS SHOWN AS A REFERENCE <br /> MANUFACTURERS PRODUCT DATA SHEET, SUBJECT AND IS SUBJECT TO CHANGE. /� <br /> TO CHANGE. CONTRACTOR TO VERIFY. 4. MOUNTING SHOWN AS TYPICAL. VERIFY CAMP'S" <br /> ACTUAL CONDITIONS IN FIELD. <br /> 5. TO ENSURE ADEQUATE AIRFLOW BETWEEN UNITS ASSOCIATES <br /> ALLOW A MINIMUM OF 1534" FREE SPACE <br /> BETWEEN RRUS INSTALLED VERTICALLY ON A 40TH <br /> 19401AVE.W.,SUITE 304 <br /> POLE. ALLOW A MIN. OF 18W' BETWEEN RRUS 01 OD,WA 98036 <br /> RRUS-32 PER PLA11111i , AND ANTENNA, IF INSTALLED ABOVE OR BELOW PHONE:(425)740-6392 <br /> FAX:(425)224-1614 <br /> � NOTE: WEIGHT OF UNIT <br /> RRUS INSTALLED SIDEI BYUMY SIDE. THE MINIMOF 77/8" BETWEEN WWW.CAMPASSOC.COM <br /> 1 1111 <br /> IS 51 LBS (VERIFY) DISTANCE FROM THE BOTTOM OF THE RRUS TO <br /> THE FLOOR IS 113'x" PROJECT MANAGER: EJC <br /> PREPARED BY: JOT/EAT <br /> Il APPROVED BY: EJC <br /> MOUNTING PIPE <br /> 12.06" EAT 11/22/17 ISSUE0 FOR PERMIT <br /> EAT 11/3/17 ISSUED FOR PRELIM REVIEW <br /> PLAN REVIEWERS SIGNATURE <br /> .-■ MOUNTING PIPE Ill= <br /> MOUNTING HARDWARE <br /> INCLUDED <br /> OK <br /> LSmmi-itilV <br /> I ,,,„,,,,,,, , <br /> II <br /> REMOTE RADIO V J <br /> UNIT (RRUS-32) m ...ill RADIO / a <br /> UNIT(RRU-32) <nv t On \ C <br /> C / , • li 1 C <br /> cia -sr <br /> NAN <br /> ipi - <br /> 14 HEFT NA,- <br /> N1111111r DETAILS <br /> I I <br /> SIDE FRONT <br /> SHEET NUMBER <br /> A-4 <br /> RRUS-32 MOUNTING DETAIL NOT USED PROJECT NUMBER 7 <br /> 20171559411 ? , <br /> 5 NOT TO SCALE NOT TO SCALE <br />