1 <br /> f � <br /> ; <br /> A PORTION OF THE S.W. 1 /4 OF THE N.E. 1 /4 OF � <br /> SECTION 6, T. 28N., R.5E., W.M. <br /> SNOHOMISH COUNTY, WASHINGTON �, <br /> SSMH-200 � <br /> �PP RIM=386.64 <br /> N IE=367.79 <br /> S IE=367.89 <br /> � <br /> I > <br /> � 3 WATER DISTRIBUTION NOTES: <br /> 3 A. No connection to the existing mains wiil be allowed except by means of an approved <br /> CHILEL�I ba�kfioW prevention device prior to satisfactory flushing, testing, disinfection, and ' <br /> A CON DOM I N I U M receipt of satisfactory bacteriological test results. <br /> B. Connections to and taps on existing mains will be made by the Public Works <br /> 3 sER cE AF#9006285018 Department at the developer's expense. The Pubiic Works Department shall be given - <br /> �13 � � o o� 1 at least 5 business days notice for each connection. The Public Works Department � <br /> � 0 shali thereafter determine the date and time at which the connection shali be made. <br /> � CONTRACTOR TO VERiFY � <br /> OCATIONANDELEVATIONOF � C. /��� work and materials C71USt conform t0 Clty of Everett Standards. <br /> CB-216 THE30°WATERLINE � D. A pre-construction meeting shall be held with the City prior to the start of <br /> R = . �� 1-INCHMETEREDWATER WATEREASEMENT COtIStrUCtl011. TIlB Clty of Everett Public Works Construction �IVISIOCI t'1"IUSt be <br /> IE=386.86 3 SERVICE(TYP.) (15'WIDE) <br /> y COESTD.DWG.:502C IIOtIfIEC� at least 24 hours prior to commencement of construction. <br /> 0 CONC. WAIL W/5` CHAINLINK FENCE N9�'oo'oo"w 250.0o E. The developer or the developer's authorized agent shall notify the Public Works <br /> 30. �y� 5' LANDSCAPE AREA (TYP.) RECY LI c 392 g2 GRAPHIC SCALE Department of a person who can be contacted regarding problems during construction <br /> CB- 1 �y9 on a 24 hour basis. <br /> TAPPINGTEE RIM=388.3 6��DEC 2� 0 10 20 40 F. Maintain a minimum of 10 feet horizontal Qtl(� 18 inches vertical separation between • <br /> COESTD.DWG.: 514 IE=386.93 � o °- _ _ _ _ _„ � _ T � potable and non-potable conveyance systems. <br /> 3 — — — — — — — — — — — — — — — — — — — — — — — — 2 BLOW-OFFASSEMBIY W G. All City of Everett valves shail be operated by Public Works Department personnel <br /> NEW 2"DI F- � NEW 2"DI COE STD.DWG.511 �+- p <br /> w � Z � only. All valves, new and existing, shall be accessible at all times. . <br /> � � � ( IN FEET ) <br /> APPRO . LOCA ON OF Y � � a 1 inch = 20 ft. <br /> 30" W ER LIN PER — — — — — — ... — — — — . — — •� — _ <br /> 3 RECOR INFOR ATION o _ -- :.:�;:.::. �•�;-:r=:. _ :�;::�:.,, v � <br /> o � N a 3g6 "-�o � <br /> APPROX. LOCATION OF � � Z rn w � � / LEGEND <br /> s" WATER LfNE PER M � �"' o FF 394 FF 394 FF 394 FF 39 3s 394 F�3 F 394 FF 394 FF 4 0 <br /> RECORD INFORMATION w� W o <br /> � � � o 0 12 N 4 0 0 0 0 0 � <br /> p � � FOUND MONUMENT � WATER METER <br /> � 3 AS DESCRIBED <br /> 3 a `` Q 23� T•�P � FIRE HYDRANT <br /> o Z • FOUND CORNER icv <br /> o . <br /> DRIVE � AS DESCRIBED � IRRIGATION CONTR L VALV <br /> 9 ❑ CATCH BASIN `�.� POWER POLE S A N I TA R Y S E WE R N 0 TE S: <br /> � , S90'0o'00 E 25 .00 6' BOARD FENCE s SANITARY SEWER MANHOLE � POWER VAULT The following standard notes are required on all Sanitary Sewer Plans: <br /> 3 W SEWER CLEAN-OUT SIDE SEWER STUB CONNECTION(TYP.) O � <br /> 3 N COESTD.DWG.t604 6"PVCSANITARYSEWER SANITARYSEWERCLEANOUT COESTD.DWG.:602 SANITARYSEWERCLEANOUT WV � ELEC J/BOX A. All work and materiais shall conform t0 the Clty of Everett Standards and WSDOT/APWA Standard , <br /> NEWSEWERCONNECTION � Q COESTD.DWG.:604 COESTD.DWG.:604 � WATER VALVE � TELEPHONE VAULT Specifications. <br /> COESTD.DWG.:613 APPROX.LOCATIONOF B. NO part of the sanitary sewer system shall be covered, concealed or put into US2 UCitl� it has been tested, <br /> EX.SANITARYSEWERSTUB � CABLE TV PED inspected, and approved by the city inspector. <br /> ,� � -222 PERREGORDINFORMATION C. ApprOXltYIQt@ locations of existing utilities have been obtained from available records QnC) are shown <br /> TRENCH � CONTRACTOR TO VERIFY LOCATION H I D D E N G R E E N S <br /> COESTD.DWG.:610 �' FND CONC M N for convenience. The contractor shall be responsible for verification of focations and to avoid damage <br /> 3 A CONDOMINIUM to any additional utilities not shown. ff conflicts with existing utilities arise during construction, the <br /> � IN C SE VERIFY SIZE OF <br /> 12— —14 EX.SANITARYSEWERSTUB AF#200707205315 contractor shall notify the public works inspector and any changes required shall be approved by the <br /> MIN.SIZEREQUIREDIS6° Cit En ineer rior to commencement of related construction on the � <br /> $ COE STD.DWG.:601,602,AND 604 y g (� pro'ect. <br /> g� D. All sewer main extensions within the public right-of-way or in easements must be staked by survey for <br /> �, 3 line and grade prior to starting construction. ' <br /> 3 $ <br /> $ FND CONC M N <br /> . ,z IN CASE <br /> 12-2-14 NOTE: EXISTING HOUSE AND SHEDS TO BE <br /> PP � DEMOLISHED AND REMOVED � <br /> � 3 <br /> 3 M� <br /> ' I w <br /> 1L�CONTRACTOR TO VERIFY LOCATION AND ELEVATION 4F THE 30° WATER LINE <br /> CONSTR UCTION SEQ I�ENCE: <br /> 1. Arrange and attend pre—construction meeting. Certified erosion control specialist shall be - <br /> identified at the pre—construction meeting. a PER COE STD. DWG,: 524B - TYPICAL MULTIPURPOSE PIPING SYSTEM DIAGRAM , <br /> 2. Fiag property lines and clearing limits. <br /> 3. Install erosion control measures and devices per approved plans. <br /> 4. Install silt fences or hay bales controis; install catch basin protection inserts; adjust as <br /> , needed during construction. insure all surface flows are controlled and routed through rEsc NOTES: <br /> control <br /> 5. Clear grub and rough grade. <br /> 6. Complete site excavation and grading activities in accordance with plans. <br /> �. instaii Qii uti�ities. 13D YSTEM IS REQIRED <br /> 8. Hydro seed, mulch, and plant landscape <br /> 9. Remove remaining TESC structures after the site has been stabilized and approved by the <br /> county development inspe�tor 13D Sltlgle-Family Home Sprinkler System - Valves shail be in heated rooms or garages. <br /> 10. Full compliance with DOE best management practices is required for this project C A �� 2 D A YS <br /> Minimum temperature shall be maintained at 40° F (NFPA 13D & 13R 8.3.1). <br /> BE �ORE YOU DIG y <br /> 1 - 800 - 424- 5555 <br /> ���. ���� � � � <br /> �'hi� �ecord Drawing has�een preparzd, in part, based <br /> on"As-Suilt" information pr�vided by o�hers.Thougn <br /> the as-built information and tt7is drawing are based on <br /> the �es uv ilable infiorma�ion, no resumption should <br /> r�e rr?�de egard g the c' N� ccuracy. � . <br /> �...--�' � f��� <br /> �i��Q � Dat� <br /> /�-�U�� �L���� P2rmit Inspsc'tor <br /> �Int N�ri�n R<� tl� _ �_ --� <br /> OWNER/APPLICANT/CONTACT, MAHER WELAYE, P.E.___ P�,oRWwF�9� 9 UNITS CONDOS � <br /> AHMET KULAGA 15516 56TH AVE. W � ,��, ti� �, SITE UTIUTIES PLAN <br /> 12 0 5 13 0 t h S t S E U N I T A EDMONDS, WA 98026 ;� �► Z f o r <br /> EVERETT, WA 98208 PH.• (206� 816-0455 AHMET KULAGA <br /> 425-501 -6441 maherwelayeC4�gmail.com ,� � 33264 0 �� DRAWN BY M. W. DATE 11/QS/2015 JOB N0. 14-121 <br /> �dc` FG/STERE �� <br /> �SSioNA� �� SITE ADDRESS <br /> 5805 HIGHWAY PL. CHECKED BY M, y�/, SCALE 1" = 20' SHEET <br /> ExPiREs a�-29--_ EVERETT, WA 98203 <br /> 40F5 ' <br />