Laserfiche WebLink
Chapter 4.Accessible Routes ICC A117.1-2009 <br /> 404.3.2 Maneuvering Clearances. Maneuvering 405.5 Clear Width. The clear width of a ramp run shall <br /> clearances at power-assisted doors shall comply with be 36 inches (915 mm) minimum. Handrails and hand- <br /> Section 404.2.3. rail supports that are provided on the ramp run shall not <br /> 404.3.3 Thresholds. Thresholds and changes in project into the required clear width of the ramp run. <br /> level at doorways shall comply with Section 404.2.4. 405.6 Rise. The rise for any ramp run shall be 30 <br /> 404.3.4 Two Doors in Series. Doors in series shall inches (760 mm) maximum. <br /> comply with Section 404.2.5. 405.7 Landings. Ramps shall have landings at the bot- <br /> 404.3.5 Control Switches. Manually operated con- tom and top of each ramp run. Landings shall comply <br /> trol switches shall comply with Section 309.The clear with Section 405.7. <br /> floor space adjacent to the control switch shall be 405.7.1 Slope. Landings shall have a slope not <br /> located beyond the arc of the door swing. steeper than 1:48 and shall comply with Section 302. <br /> 405.7.2 Width. Clear width of landings shall be at <br /> 405 Ramps least as wide as the widest ramp run leading to the <br /> 405.1 General. Ramps along accessible routes shall landing. <br /> comply with Section 405. 405.7.3 Length. Landings shall have a clear length <br /> EXCEPTION: In assembly areas, aisle ramps adja- of 60 inches (1525 mm) minimum. <br /> cent to seating and not serving elements required to <br /> 405.7.4 Change in Direction. Ramps that change <br /> be on an accessible route shall not be required to direction at ramp landings shall be sized to provide a <br /> comply with Section 405. <br /> turning space complying with Section 304.3. <br /> 405.2 Slope. Ramp runs shall have a running slope <br /> greater than 1:20 and not steeper than 1:12. 405.7.5 Doorways.Where doorways are adjacent to <br /> a ramp landing, maneuvering clearances required by <br /> EXCEPTION: In existing buildings or facilities, ramps Sections 404.2.3 and 404.3.2 shall be permitted to <br /> shall be permitted to have slopes steeper than 1:12 overlap the landing area. Where a door that is sub- <br /> complying with Table 405.2 where such slopes are ject to locking is located adjacent to a ramp landing, <br /> necessary due to space limitations. the landing shall be sized to provide a turning space <br /> 405.3 Cross Slope. Cross slope of ramp runs shall not complying with Section 304.3. <br /> be steeper than 1:48. 405.8 Handrails. Ramp runs with a rise greater than 6 <br /> 405.4 Floor Surfaces. Floor surfaces of ramp runs inches (150 mm) shall have handrails complying with <br /> shall comply with Section 302. Section 505. <br /> TABLE 405.2—ALLOWABLE RAMP DIMENSIONS FOR CONSTRUCTION IN EXISTING SITES,BUILDINGS AND FACILITIES <br /> Slope.' Maximum Rise <br /> Steeper than 1:10 but not steeper than 1:8 3 inches(75 mm) <br /> Steeper than 1:12 but not steeper than 1:10 6 inches(150 mm) <br /> i g <br /> 1A slope steeper than 1:8 shall not be permitted. <br /> 60 min 60 min 60 min <br /> 1525 1 1525 f / 1525 <br /> landing ramp run landing ramp run c <br /> �- 1L/ landing •8 <br /> to <br /> at least as wide as ramp run <br /> (a) <br /> ramp > <br /> run <br /> V <br /> (b) <br /> FIG.405.7 _ <br /> RAMP LANDINGS <br /> ''' ')/111 <br /> `` f' <br /> 412" i 1 <br />