Laserfiche WebLink
r Job Truss Truss Type Qty Ply submittals <br /> 111803702 <br /> 05706360 A01 Common Girder 1 3 Job Reference(optional) <br /> The Truss Co., Burlington,WA,98233 8.030 s Oct 5 2016 MiTek Industries,Inc.Tue Jul 11 09:40:51 2017 Page 1 <br /> I D:DYVe4WH3wNiyn_iNU 1 ZZcRz3MY8-BH5fRr6k6KYPPL7wPCM23RKdUn41 vriK3pqHs6yzAiA <br /> 3-9-4 6-10-0 9-11-12 I 13-8-0 <br /> 3-8-4 3-1-12 3-1-12 3-8-4 <br /> 4x6= Scale=1:28.7 <br /> 3 <br /> ill <br /> 6.00iih\12 <br /> 8 9 <br /> 2x4 VA 2x4// <br /> 2 ------'- 4 <br /> c5 \ <br /> a5 <br /> e1 OM 11 1� _ - — - B1 — 11 Y 11 11 x% 17 <br /> 10 11 7 12 13 6 14 15 <br /> RN 0 .4 <br /> HUS26 HUS26 4x6= HUS26 HUS26 4x6 = HUS26 <br /> 4x8 = 4x8 = <br /> HUS26 <br /> 4-8-13 8-11-3 13-8-0 <br /> 4-8-13 4-2-5 4-8-13 <br /> Plate Offsets(X,Y)-- (1:0-4-0,0-1-15),(5:0-4-0,0-1-151 <br /> LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.13 Vert(LL) -0.05 6-7 >999 240 MT20 185/148 <br /> (Roof Snow=25.0) Lumber DOL 1.15 BC 0.26 Vert(CT) -0.08 6-7 >999 180 <br /> TCDL 8.0 Rep Stress Incr NO WB 0.31 Horz(CT) 0.01 5 n/a n/a <br /> BCLL 0.0 <br /> BCDL 7.0 * Code IRC2015/TPI2014 Matrix-SH Weight:212 lb FT=20% <br /> LUMBER- BRACING- <br /> TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. <br /> BOT CHORD 2x8 DF SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br /> WEBS 2x4 DF Stud <br /> REACTIONS. (lb/size) 1=3418/0-5-8 (min.0-1-8),5=3224/0-5-8 (min.0-1-8) <br /> Max Horz 1=74(LC 27) <br /> Max Uplift 1=-1252(LC 10),5=-1180(LC 11) <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. <br /> TOP CHORD 1-2=-5559/2022,2-8=-5436/2004,3-8=-5407/2012,3-9=-5373/2000,4-9=-5401/1992, <br /> 4-5=-5523/2010 <br /> BOT CHORD 1-10=-1835/4936,10-11=-1835/4936,7-11=-1835/4936,7-12=-1182/3370, <br /> 12-13=-1182/3370,6-13=-1182/3370,6-14=-1749/4903,14-15=-1749/4903, <br /> 5-15=-1749/4903 <br /> WEBS 3-6=-1017/2683,3-7=-1037/2741 <br /> NOTES- <br /> 1)3-ply truss to be connected together with 10d(0.131"x3")nails as follows: <br /> Top chords connected as follows:2x4-1 row at 0-9-0 oc. <br /> Bottom chords connected as follows:2x8-2 rows staggered at 0-5-0 oc. <br /> Webs connected as follows:2x4-1 row at 0-9-0 oc. <br /> 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section. <br /> Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. <br /> 3)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=103mph;TCDL=4.2psf;BCDL=4.2psf;h=25ft;Cat.II;Exp C;enclosed; <br /> MWFRS(envelope)gable end zone;cantilever left and right exposed;end vertical left and right exposed;Lumber DOL=1.60 <br /> plate grip DOL=1.60 <br /> 4)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp C;Partially Exp.;Ct=1.1 <br /> 5) Unbalanced snow loads have been considered for this design. <br /> 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 7)*This truss has been designed for a live load of 23.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 <br /> wide will fit between the bottom chord and any other members. i L. Q <br /> 8) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1252 lb uplift at joint 1 and 1180 lb +04 IVASN ' <br /> uplift at joint 5. 4 <br /> 9)Use USP HUS26(With 16d nails into Girder&16d nails into Truss)or equivalent spaced at 2-0-0 oc max.starting at 1-7-4 from fte- %y� <br /> the left end to 11-7-4 to connect truss(es)B02(1 ply 2x4 HF)to front face of bottom chord. � n5 074 <br /> 10) Fill all nail holes where hanger is in contact with lumber. I.C� /" <br /> LOAD CASE(S) Standard 4 1fi -' <br /> 19969 <br /> Continued on page 2 > 4. +'-0 <br /> July 11,2017 <br /> r I <br /> AA' <br /> A WARNING•Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE Mll-7473 BEFORE USE. ` <br /> Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. <br /> Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown <br /> is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the <br /> a <br /> erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding <br /> fabrication,quality control,storage,delivery,erection and bracing,consult ANSIITPII Quality Criteria,DSB-89 and BCSII Building Component y � <br /> Safety Information available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719. he irf�RUSSCO.INC. <br />