Laserfiche WebLink
Job Truss Truss Type Qty Ply submittals <br /> 111803709 <br /> BB706360 CO3 Common 1 1 Job Reference(optional) <br /> The Truss Co., Burlington,WA,98233 8.030 s Oct 5 2016 MiTek Industries,Inc.Tue Jul 11 09:40:57 2017 Page 1 <br /> ID:DYVe4WH3wNiyn_iNU 1 ZZcRz3MY8-?RTwiuBVhAJZ7Gb4ITTTJiadLC27Jb7CSIHc4lyzAi4 <br /> 1 4-10-4 I 9-2-0 I 13-5-12 I 18-4-0. I <br /> 4-10-4 4-3-12 4-3-12 4-10-4 <br /> 4x4 = Scale=1:37.3 <br /> 3 <br /> 6.00 112 <br /> 7 8 <br /> 2x4 2x4 i <br /> 2 4 <br /> N, .1 <br /> v <br /> v W1 <br /> 1 5 <br /> 71 w EL to <br /> 6 <br /> 4x4 = 4x4= <br /> 3x8 =- <br /> I <br /> I 9-2-0 I 18-4-0 I <br /> 9-2-0 9-2-0 <br /> Plate Offsets(X,Y)-- [1:0-1-8,Edge],[5:0-1-8,Edge] <br /> LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP <br /> TCLL 25.0 Plate Grip DOL 1.15 TC 0.30 Vert(LL) -0.13 1-6 >999 240 MT20 185/148 <br /> (Roof Snow=25.0) Lumber DOL 1.15 BC 0.60 Vert(CT) -0.24 1-6 >888 180 <br /> TCDL 8.0 Rep Stress Incr YES WB 0.18 Horz(CT) 0.03 5 n/a n/a <br /> BCLL 0.0 * Code IRC2015/TP12014 Matrix-SH Weight:64 lb FT=20% <br /> BCDL 7.0 <br /> LUMBER- BRACING- <br /> TOP CHORD 2x4 HF No.2 TOP CHORD Structural wood sheathing directly applied or 4-9-2 oc purlins. <br /> BOT CHORD 2x4 HF No.2 BOT CHORD Rigid ceiling directly applied or 8-6-10 oc bracing. <br /> WEBS 2x4 DF Stud MiTek recommends that Stabilizers and required cross <br /> bracing be installed during truss erection,in accordance with <br /> Stabilizer Installation guide. <br /> REACTIONS. (lb/size) 1=722/0-3-8 (min.0-1-8),5=722/0-3-8 (min.0-1-8) <br /> Max Horz 1=-104(LC 11) <br /> Max Uplift 1=-255(LC 10),5=-255(LC 11) <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. <br /> TOP CHORD 1-2=-1234/443,2-7=-906/299,3-7=-831/310,3-8=-831/310,4-8=-906/299, <br /> 4-5=-1234/443 <br /> BOT CHORD 1-6=-430/1057,5-6=326/1057 <br /> WEBS 3-6=-130/487,4-6=-392/300,2-6=-392/299 <br /> NOTES- <br /> 1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=103mph;TCDL=4.2psf;BCDL=4.2psf;h=25ft;Cat.II;Exp C;enclosed; <br /> MWFRS(envelope)gable end zone;cantilever left and right exposed;end vertical left and right exposed;Lumber DOL=1.60 <br /> plate grip DOL=1.60 <br /> 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp C;Partially Exp.;Ct=1.1 <br /> 3)Unbalanced snow loads have been considered for this design. <br /> 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 5)*This truss has been designed for a live load of 23.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 <br /> wide will fit between the bottom chord and any other members. <br /> 6) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)except(jt=lb) <br /> 1=255,5=255. <br /> LOAD CASE(S) Standard <br /> 'i L. P(} <br /> "., ,, , . <br /> " , t <br /> 4,;1611, <br /> V. xT <br /> 19969 <br /> July 11,2017 <br /> t t <br /> © WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE M11.7473 BEFORE USE. <br /> Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. <br /> Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown <br /> is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the <br /> erector,Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding <br /> fabrication,quality control,storage,delivery,erection and bracing,consult ANSIITPII Quality Criteria,DSB-89 and BCS11 Building Component �tf / <br /> � <br /> Safety Information available from Truss Plate Institute,583 D'Onofrio Drive,Madison,151 53719. theTRUSSco.RUSSco.INC. /`+/{1 <br />