Laserfiche WebLink
Interior Lighting - Spare-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Manor Hardware Warehouse Date 8/11/2017 <br /> Calculation ® 0 Addition- 0 Addition For Building Department Use <br /> ��y stand alone +existing <br /> Area <br /> 0 Spaces where<50%of 0 Spaces where>_50%of 0 <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard O Additional Efficiency Package Option 0 <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3, the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE' <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Warehouse Warehouse:Medium/bulky palletized items 7058 0.460 3247 <br /> Sales Sales area 2941 1.270 3735 <br /> Mezzanine Warehouse:Smaller,hand carried items 2813 0.760 2138 <br /> Total Area 12812 , <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 9120 <br /> Proposed Lighting Wattage"'t' <br /> Location(plan#, Number of Watts! # '; Watts <br /> NOTE 4,5,6 NOTE 7 `'i `''k-11'4174,047: <br /> Proposed <br /> room#) Fixture Description Fixtures Fixture .- a <br /> Warehouse LED 2X4 12 70 r 840 <br /> Sales LED 2X4 28 70 i r' 1960 <br /> Tool Repair LED 1X4 6 35 i•PAW'''.�-47 , 210 <br /> A,4s," . <br /> Mezzanine Storage LED 1X4 22 35 g X"r., 770 <br /> Fes v,_ <br /> Office LED 2X4 2 70 140 <br /> Breakroom LED 2X4 2 70 q 4.- 140 <br /> Restroom 104 Recessed LED 1 35 4E .- 35 <br /> Restroom 204 Recessed LED 1 35 ° ,i 35 <br /> Hall 105 LED 1X4 1 35 , 4r v 35 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 4165 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. ^` 0 <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided /I <br />