Field Report Report#: 71274 <br /> A.A.R.Testing Laboratory,Inc.7126180th Ave.k.E.,Park 180, Suite 0101,Redmond,WA 98052 <br /> Phone 425.881.5812 Fax 425.881.5441 <br /> Client: NorthWest Handling Systems,Inc. Project Number: 18-374 <br /> 1100 SW 7th St. Permit#: B1804-025 <br /> Renton,WA 98055-2939 <br /> Project Name: Manor Hardware <br /> Contact: Neil Montague Address: 3310 McDougall Ave. <br /> Inspection Performed: Proprietary Anchors <br /> Date: 5/11/2018 Time: Temperature: <br /> Inspected wedge anchors for storage racks. <br /> Anchors conform to note#4 for type of anchors, Hilti KB-TZ 1/2"diameter. And detail#1 on plans <br /> being 1/2"diameter and minimum two anchors per base plate. <br /> All anchors in full contact. Using a calibrated torque wrench, all anchor tested found to meet or <br /> exceed the minimum 40 ft./lbs. requirement. <br /> Distribution: [i Distribute Client Li Distribute Contractor <br /> Inspector: Matthews,Bill <br /> Distribute Engineer ❑ Distribute Owner <br /> INel Distribute Municipality Li Distribute Other Reviewed by: Michele Guerrini <br /> Distribute Architect ❑ Distribute Other <br /> All reports are considered confidential and are the property of the client and A.A.R.Testing Laboratory,Inc. <br /> Reproduction except in full without the written consent of A.A.R.Testing is strictly forbidden <br />