Laserfiche WebLink
1 <br /> Brian <br /> 360-424-8700 <br /> From:Allen Tucker [mailto:allent@visserengineering.com] <br /> Sent:Tuesday,April 12, 2016 12:20 PM <br /> To: 'Gabi Muller'<gabi@cba-arch.com> <br /> Cc: 'Brian Ruthford'<brianr@crestconstruction.com>; 'Michael E. Ruthford'<miker@crestconstruction.com> <br /> Subject: RE:Special Interest Autobody-2-hour fire wall clip cut sheet <br /> Gabi: <br /> For typical wall. <br /> Minimum of(3) Fast Clip screws, 1 per slot in top of slot to existing Z purlin. Min (3) #12 screws to 20 ga Top Track. <br /> What's their plan for the HSS Jambs? Door closed. Wall loading with jamb horiz loading exceed the 386#clip capacity. <br /> A.Tucker-Visser Engineering <br /> (253) 835-0810 <br /> allent@visserengineering.com <br /> From: Gabi Muller [mailto:gabi@cba-arch.com] <br /> Sent: Tuesday, April 12, 2016 11:21 AM <br /> To: Allen Tucker <br /> Cc: 'Brian Ruthford'; Michael E. Ruthford <br /> Subject: Special Interest Autobody - 2-hour fire wall clip cut sheet <br /> Hi Allen— <br /> Please review the cut sheet(link below) and sketch from the contractor and let me know if this is acceptable from a <br /> structural standpoint.Thanks, <br /> Gabi <br /> Gabrielle Muller <br /> CB ANDERSON ARCHITECTS PLLC <br /> 7209 Greenwood Avenue N 206-782-2911 <br /> Seattle Washington 98103 Fax-782-5624 <br /> ciabi@cba-arch.com <br /> www.cba-arch.com <br /> From: Brian Ruthford [mailto:brianr@crestconstruction.com] <br /> Sent:Tuesday,April 12, 2016 10:47 AM <br /> To:Gabi Muller<gabi@cba-arch.com> <br /> Cc: Mike Ruthford<miker@crestconstruction.com>; 'Rusty Noble'<rusty@gkknutson.com> <br /> Subject: FW: clip cut sheet <br /> Gabi, <br /> 2 3¢ <br />