My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
224 109TH ST SE 2019-01-30
>
Address Records
>
109TH ST SE
>
224
>
224 109TH ST SE 2019-01-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2019 12:06:18 PM
Creation date
1/30/2019 12:06:12 PM
Metadata
Fields
Template:
Address Document
Street Name
109TH ST SE
Street Number
224
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> AFH for Vincent Namamba &Patricia Lukano Fred Brown <br /> 224 109th St.SE 2008 Hoyt Ave <br /> Everett,/WA Everett,WA 98201 <br /> Heating System Type: O All Other Systems O Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Design Temperature Difference(AT) 47 <br /> Everett 1C <br /> __. - __. __— ____ _— AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 1,910 <br /> Average Ceiling Height Conditioned Volume <br /> Instruction: Average Ceiling Height(ft) 8.0 15,280 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructing•,: <br /> H 0.30 v 0.300 253 76.02 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> [R-38 Advanced <br /> 0.026 1,910 49.66 <br /> Single Ratter or Joist Vaulted Ceilings U-Factor X Area UA <br /> stCuct iorNo selection <br /> Select R-Value --- <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 0.056 1,384 77.50 <br /> 5-21 Intermediate . <br /> .41 <br /> - ._..._..x �--....-sti 1.--... <br /> Floors U-Factor X Area UA <br /> LR 30 0.029 1,910 55.39 <br /> .111J <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions No selection <br /> Select Rvalue <br /> Slab Below Grade(see Fioure tl F-Factor X Le <br /> UA <br /> Instructions. No selection --- <br /> Select conditioning rr--��--�� <br /> Slab on Grade(see Figure a F-Factor X Lett UA <br /> Instructions. No selection <br /> Select R-Value •tr; <br /> Location of Ducts <br /> Duct Leakage Coefficient <br /> Unconditioned Space <br /> _—_— 1.10 <br /> Sum of UA 258.57 <br /> Envelope Heat Load 12,153 Btu/Hour <br /> Figure 1. Sum ofuAXIT <br /> Air Leakage Heat Load 7,756 Btu/Hour <br /> nN ,,,:tea VolumeX 0.6X\T X.018 <br /> ' wow:Grade I Building Design Heat Load 19,909 Btu/Hour <br /> - Air Leakage r-Envelope Heat Loss <br /> ,Below Grade <br /> Building and Duct Heat Load 21,900 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 27,375 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> ([l (07/01/73) <br />
The URL can be used to link to this page
Your browser does not support the video tag.