• GENERAL • YES NO <br /> Bathroom <br /> Bathroom doors are easily and quickly openable from the outside when locked • <br /> Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. [�/0 <br /> Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate <br /> sleeping area in the immediate vicinity of sleeping rooms(R314). E 0 <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all <br /> UK-0 <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 0K 0 <br /> Pocket doors shall have graspable hardware available when in the closed or open position. 0r- 0 <br /> R311.8 Ramps - YES NO <br /> Inside Ramp. N/A 0 0 <br /> R311.8.1 Maximum Slope one unit vertical In twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) [] <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes <br /> directions. [ <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1-R311.8.3.3. �0 <br /> Outside Ramp N/A 0 • <br /> YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) Ilk" <br /> 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes <br /> directions. 0'-0 <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1-R311.8.3.3. El"- 0 <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards [Eye 0 <br /> • <br /> Handrail both sides <br /> Less than 4" 34"-38" <br /> Guard <br /> 36"min <br /> '-e-1Y �„ a 3'x 3'min <br /> landing <br /> 3'x3'min <br /> landing <br /> 3' One unit vertical in twelve units horizontal �.—3'—..I <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress - YES NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. V' <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). gr0 <br /> R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry 0' 0 <br /> without use of key,tool or spec' owledge. Required exit door shall have no additional locking devices. <br /> R311.7 Stairways N/A S YES NO <br /> R311.7.4.1 Riser Height:Max riser height shall be 7% inches(8 inches in structures built prior to July 1,2004) 0 0 <br /> R311.7.4.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 0 <br /> risers.Handrails shall be installed in accordance with R311.7.7.1-R311.7.7.4 <br /> Effective:2013 July 01 <br /> Updated:2013 June," <br /> l ' <br />