My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
224 109TH ST SE 2019-01-30
>
Address Records
>
109TH ST SE
>
224
>
224 109TH ST SE 2019-01-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2019 12:06:18 PM
Creation date
1/30/2019 12:06:12 PM
Metadata
Fields
Template:
Address Document
Street Name
109TH ST SE
Street Number
224
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ItNAME OF AFH: / S t.4 I,l is L web M e <br /> SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br /> PLEASE CHECK ALL APPLICABLE BOXES;MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE RESIDENT <br /> BEDROOM DESIGNATIONS OF A B CD SAND FAND CLASSIFICATION CODES,NS1 OR NS2. <br /> SECTION 5—BUILDING INSPECTOR'S INSPECTION CHECKLIST <br /> R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br /> Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. <br /> Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R325.9 is provided to evacuate residents to public area. <br /> Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with R325.9 are provided to evacuate residents to public area. <br /> SLEEPING ROOM A ❑Type S ❑Type NS1 0 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked ❑ 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ 0 <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted 0 ❑ <br /> SLEEPING ROOM B 0 Type S ❑Type NS1 0 Type NS2 YES NO>_ <br /> Closet door/s are readily openable from the inside ❑Yes . 0 No Smoke alarm is installed in the bedroom 9 9 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ 0 <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted ❑ 0 <br /> SLEEPING ROOM C ; El Type S 0 Type NS1 ❑Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes 9 No Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximumsill height of 44"above floor;no steps under window permitted ❑ ❑ <br /> SLEEPING ROOM D ❑Type S 0 Type NS1 ❑Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes El No Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor; no steps under window permitted ❑ ❑ <br /> SLEEPING ROOM E ❑Type S El Type NS1 ❑Type NS2 YES NO. <br /> Closet door/s are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom 0 El <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted 0 0 <br /> SLEEPING ROOM F ❑Type S ❑Type NS1 ❑Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes ❑No Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted ❑ ❑ <br /> Effective: 2013 July 01 <br /> Updated: 2013 June <br />
The URL can be used to link to this page
Your browser does not support the video tag.