Laserfiche WebLink
Duct Testing Calculator (New Construction) <br /> House address or lot#: 5-5-- q ftif- " <br /> Conditioned Floor Area: I . r cyc7 <br /> i <br /> Duct tester location:. <br /> Pressure <br /> Pressure tap location: Al i <br /> • Ring(if applicable): Open 0 1 0 2 0 3 0 <br /> h <br /> At Rough-ln or Post Coristruction <br /> Calculated Test' <br /> • Test Method Standard' <br /> Target CFM25 <br /> Air Handler Present <br /> <4 CFM,5 per 100 sf of CFA tr)( .ek <br /> (Leakage to Exterior or Total Leakage) <br /> Air Handler not Present <br /> 5 3 CFIlillsper 100 sf of CFA <br /> (Leakage to Exterior or Total Leakage) <br /> 1, Test CFM25must be equal to or less than the calculated target <br /> Air Leakage testing Calculator(Blower Door Test) <br /> Conditioned Floor Area: i i rev:, Calculated Volume(cubic feet) <br /> Ceiling Hieght(ft) g -p / 4, Yoto <br /> IN, rn <br /> Standard Tested CFM50 Calculated Test) L.5 <br /> fl Result(ACHso „,,,_ . <br /> _15.0 ACi-lso (cFivisoxxo-,izTro...:-..„--/1.410) :-. q <br /> 60+conditioned Volume) - - <br /> Glossary <br /> • Rough-hi: After installation of the complete air distribution system but before installation of insulation and sheet <br /> rock. Allows for access to all duct seams and connections for re-evaluation of seal integrity if standard is not met in <br /> intitial test <br /> Post Construction: At or near final inspection. The home must be complete enough to pressurize the home to 25 <br /> • pa. <br /> TotalLeakage: Aggregation of the entire systems duct leakage in a duct test. <br /> • Leakage to Exterior: Aggregation of all duct system leaks to the exterior of the CFA in a duct test. <br /> Pascal jpa): Unit of pressure <br /> CFA: Conditioned floor area in square feet <br />, . <br /> CFM : Cubic feet per minute of air leakage at 25 pascals of pressure <br /> CFIlilso: Cubic feet per minute of air leakage at 50 pascals of pressure <br /> Conditioned volume: Volume of conditioned space(CFA X ceiling hieght) <br /> ACHsa: Air changes per hour at SO pascals of pressure <br /> '43 <br />„,,, <br />