Laserfiche WebLink
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Prnjart Titter Coastal Community Bank Ti. Date 10/18/2018 <br /> Calculation 0 0 Addition- 0 Addition For Building Department Use <br /> NOTE 9 stand alone +existing <br /> Area ((�� <br /> Spaces where<500:-- f Spaces where>_bb%of <br /> Iu,n;rtaires aro rop6ced k n.,naires are replaeod <br /> LPA Standard Additional Efficiency Package Option <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE I <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Call Center 101 Office:Open plan 8'-0" 1301 0.780 1015 <br /> - <br /> Office 102 Office:Enclosed 8'-0" 128 0.890 114 <br /> Office 103 Office:Enclosed 8'-0" 110 0.890 98 <br /> Work Room 104 Office:Enclosed 8'-0" 187 0.890 166 <br /> Conference Office:Enclosed 8'-0" 672 0.890 598 <br /> Room105 <br /> Storage 106 Storage room 8'-0" 86 0.500 43 <br /> Total Area 2484 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 2035 <br /> Proposed Lighting Wattage"u't s <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE Proposed <br /> Call Center 101 LED 2X4 20 39 780 <br /> Office 102 LED 2X4 2 39 78 <br /> Office 103 LED 2X4 2 39 78 <br /> Work Room 104 LED 2X4 3 9 27 <br /> Conference LED 2X4 8 39 312 <br /> Room 105 <br /> Storage 106 LED 2X4 1 39 39 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1314 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. _- <br /> Note 9-Calculation Area Details: '\ <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building � I's`lighting systems to demonstrate compliance.Refer to C502.1. , 4 <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a / , < <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types \ r l <br /> and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br />