My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7407 EVERGREEN WAY KENTUCKY FRIED CHICKEN 2019-02-05
>
Address Records
>
EVERGREEN WAY
>
7407
>
KENTUCKY FRIED CHICKEN
>
7407 EVERGREEN WAY KENTUCKY FRIED CHICKEN 2019-02-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2019 2:49:47 PM
Creation date
2/5/2019 2:49:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7407
Tenant Name
KENTUCKY FRIED CHICKEN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> h / <br /> Exterior Lighting LTG-EXT <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: KFC E080013 7407 Evergreen Way,Everett WA 98203 Date 4/6/2017 <br /> Exterior Lighting Zone 1 Zone 2 Zone 3 0Zone 4 For Building Department Use <br /> Zone Table C405.5.2(1) <br /> Specified by jurisdiction. Zone selection required to enable LTG-EXT form <br /> Calculation Area 0 O Addition- 0 Addition <br /> stand alone +existing <br /> (-1 Alteration with<50% Alteration with a 50%ext. <br /> ext.wattage replaced wattage replaced <br /> Building Grounds 0 Efficacy>80 lumens/watt ©Exemption <br /> Applies to luminaires> <br /> 100 Watts Li Controlled by motion sensor <br /> Tradable Maximum Allowed Lighting Wattage NOTE I Base Site Allowance: 600 <br /> Area(ft`),perimeter(If) Allowed Watts Allowed Watts <br /> Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Other Entry Door Back Door 3 20W/LF door 60 <br /> Total Allowed Tradable+Site Allowance Watts: 660 <br /> Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Tradable Surface Fixture Description NOTE 3,a Fixtures Fixture NOTE 5 Proposed <br /> Other Entry Door LED 1;M-3 LED Wallpack,1 Lamp 1 20 20 <br /> Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 20 <br /> watts plus the base site allowance. Any base site allowance not needed to make <br /> tradable watts comply can be applied to individual non-tradable categories. <br /> Non-Tradable Maximum Allowed Lighting Wattage""'E' Site Allowance Remaining: 600 <br /> Area(ft2),perimeter(If) Allowed Watts Allowed Watts <br /> Non-Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Bldg.Facade Graphics 234 0.1 W/ft2 24 <br /> Bldg.Facade Signage 12 0.1 W/ft2 2 <br /> Non-Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Non-Tradable Surface Fixture Description NOTE a,a Fixtures Fixture NOTE 5 Proposed <br /> Bldg.Facade LED 2;E-1 LED Flood Light,1 Lamp 13 24 312 <br /> Bldg.Facade LED 3;E-2 LED Flood Light,1 Lamp 3 31 93 <br /> Non-tradable proposed watts may not exceed allowed watts for any individual Non-Tradable Watts Exceeding LPA: 379 <br /> surface unless the total excess watts for all non-tradable surfaces are less than the <br /> remaining site allowance. Remaining Site Allowance: 221 <br /> Exterior Lighting COMPLIES WITH MAX. ALLOWANCE <br /> Note 1-List all unique exterior sufaces per Table C405.5.2(2)that occur in the project scope.Select exterior surface categories from drop <br /> down menu. <br /> Note 2-List all proposed lighting fixtures including existing-to-remain fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type,number of lamps in the fixture,and ballast type(if applicable). <br /> Note 4-Existing-to-remain fixtures shall be included in the Tradable and Non-Tradable Proposed Lighting Wattage tables in the same manner <br /> as new fixtures.Identify as existing in fixture description. <br /> Note 5-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low - <br /> voltage lighting,enter the wattage of the transformer. °' <br /> i : <br /> I <br />