<br /> CIRCUITS LIGHTING PANELBOARDS CIRCUITS GENERAL NOTES
<br /> EMERGEMCY NOfUTAL
<br /> N/A LOWER—CASE LETTER NEAR FIXTURE DENOTES SWITCH LEG, TYP 208V SYSTEM PANELBOARD �f� RACEWAY CONCEALED IN CEILING OR WALL. HASH MARKS 1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL 925 Fourth Avenue
<br /> POLE AS SPECIFIED E; j STUB CONDUIT TO 6" BELOW ` a INDICATE NUMBER OF WIRES. 12 AWG WIRE UNLESS OTHERWISE AUTHORITY HAVING JURISDICTION. Suite 2400
<br /> !� ' HANDHOLE WITH GROUND BUSHING # Seattle, WA 98104
<br /> !i � � FIXTURE ON NORMAL AND EMERGENCY CIRCUITS 480V SYSTEM PANELBOARD NOTED. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. 2, FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, T 206 623 9414
<br /> HANDHOLE �i —� HOT (SHORT HASH MARK) AUTOMATIC SHUT—OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC T1ME SWITCHES THE F 206 623 7828
<br /> �� �� BOLT COVER �## LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS,
<br /> i �## FIXTURE IDENTIFICATION, SEE LIGHTING FIXTURE SCHEDULE EQUIPMENT, AND SYSTEMS ARE CALIBRATED, ADJUSTED, AND OPERATE IN ACCORDANCE WITH www.zgf.com
<br /> TIGHTLY PACKED GROUT UNDER POLE 1 O —� NEUTRAL (LONG HASH MARK) PROJECT PLANS AND SPECIFICAl10NS. SEQUENCE OF OPERATION SHALL ALSO BE FUNCTIONALLY
<br /> BASE TO INSURE FULL CONTACT WITH :0 ELECTRICAL RISER TESTED TO ENSURE IT IS OPERATING IN ACCORDANCE WITH PROJECT PLANS AND SPECIFICATIONS. A Consultants
<br /> FOOTING (PROVIDE WEEP HOLE) � � NUT & WASHER TO PLUMB POLE �— GROUND WIRE (JOGGED HASH MARK) COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE
<br /> � j (TWO EACH PER ANCHOR BOLT) OWNER.
<br /> n „ CIRCUITS SITE AND LANDSCAPE LIGHTING �� FEEDER SIZE IDENIIFICAl10N EXISIING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CIVIL ENGINEER
<br /> 1 x 1 CHAMFER i Eu�co+cr riora�� CONDUCTORS)
<br /> . H � Q AVAILABLE FAULT CURRENT IDENTIFICATION ____- RACEWAY BELOW SLAB OR UNDERGROUND g
<br /> o Ma nusson Klemencic Associates
<br /> EXPANSION JOINT o0 o EXPOSED PORTION OF CONCRETE BASE N �
<br /> TO HAVE RUBBED SURFACE • • ARRESTOR, SURGE 1301 Fifth Avenue, Suite 3200
<br /> SIDEWALK � � � 24„ GRADE �-� ♦Q —o RACEWAY UP ABBREVIATIONS T 000-0 0 000001-2699
<br /> a a � BUS SPACE
<br /> 0 o SPACE —� RACEWAY DOWN
<br /> LANDSCAPE ARCHITECT
<br /> • a•o: • a•o; . a•o:. �
<br /> � LIGHIING STANDARD: FIXTURES, POLE, AND BASE I I � CONTACT, NORMALLY OPEN AND NORMALLY CLOSED ABV ABOVE MDF MAIN DISTRIBUTION FRAME/FACILITY
<br /> • a•�: a•�° a•�: o —� RACEWAY STUB—OUT WITH BUSHING AC 3° ABOVE COUNTER BACKSPLASH MH MANHOLE 222 Etur aSSt eet
<br /> 0 0
<br /> ' �-�� � =_- o �� o � CIRCUIT BREAKER
<br /> o a � CIRCUIT CONTINUAl10N ACH ABOVE COUNTER HEIGHT MM MULTIMODE Seattle, WA 98109
<br /> ` o RACEWAY 24" BELOW FINAL GRADE OR AS —���"� CIRCUIT BREAKER, DRAWOUT AFF ABOVE FINISHED FLOOR MTD MOUNTED T 206-285-3026
<br /> SONOTUBE FORM REMOVE o o NOTED ON DRAWINGS (QUANTITY AS
<br /> —� NOME RUN TO PANEL OR LOCATION NOTED
<br /> 0 o REQUIRED) � GF CIRCUIT BREAKER, GFI AG ABOVE GRADE MW MICROWAVE ELECTRICAL ENGINEER
<br /> � J J JUNCTION BOX
<br /> o N/A a SITE UPLIGHT A,AMP AMPERE N NEUTRAL STANTEC CONSULTWG SERVICES
<br /> ANCHOR BOLTS AS FURNISHED VERTICAL REBAR CONTRACTOR CONFIRM �F CIRCUIT BREAKER, GFI WITH DRAWOUT 4100 194th Street, Suite 400
<br /> WITH POLE OR AS SPECIFIED � PB PULL BOX A/V AUDIO/VISUAL NIC NOT IN CONTRACT
<br /> o _ o SIZE, QUANTITY, AND SPACING) N/A � SITE UGHTING BOLLARD —��� � ATS AUTOMATIC TRANSFER SWITCH OPER OPERATER/OPERABLE Lynwood, WA 98036-4613
<br /> �--�J CIRCUIT BREAKER, THERMAL OVERLOAD T 206-667-0553
<br /> � REBAR 11ES (CONTRACTOR CONFIRM SIZE, HH HAND HOLE AWG AMERICAN WIRE GAUGE OP01 OWNER PROVIDED OWNER INSTALLED
<br /> o� 4��� QUANIITY, AND SPACING) 8�f FUSE OR CURRENT LIMITER
<br /> CAN COMMUNITY ACCESS TELEVISION PB PULLBOX
<br /> a
<br /> � � FUSE (ISOLATING) CB CIRCUIT BREAKER PNL PANEL, PANELBOARD
<br /> �
<br /> CAST—IN—PLACE CONCRETE USE AUGURED HOLE AS CONCRETE ��� WORK DEFINITION CCN CLOSED CIRCUIT TELEVISION POS POSI110N/POINT OF SALE
<br /> (CONTRACTOR CONFIRM PSI AND FORM BELOW SONOTUBE EQUIPMENT ,�� FUSED SWITCH
<br /> DIMENSIONS REQUIRED) ° o, D o CKT CIRCUIT PR PAIR
<br /> � p o � G R O U N D � F L A G N O T E C L G C E I L I N G P T S P N E U M A T I C T U B E S T A l 1 0 N
<br /> 0 0 EQUIPMENT CONNECTION, E = EMERGENCY POWER CM CEILING MOUNTED
<br /> ,� PUSHBUTTON Q REVISION IDENIIFICAl10N R RACEWAY
<br /> COMM COMMUNICATIONS RO RACEWAY ONLY
<br /> NOTE: • SPLICE # EQUIPMENT IDENIIFICATION C CONDUIT
<br /> RECEPT RECEPTACLE
<br /> CONTRACTOR TO PROVIDE STRUCTURAL ENGINEERING DRAWINGS FOR EACH BASE CO CONDUIT ONLY REF REFRIGERATOR
<br /> DETAIL CONDI110N FOR DESIGN TEAM APPROVAL PRIOR TO FABRICATION. ELECTRONIC SECURITY �� SWITCH, 2—POLE O EQUIPMENT IDENTIFICAl10N CTRL CONTROL SA SURGE ARRESTOR
<br /> DRAWINGS SHALL BE STAMPED AND SIGNED BY A STRUCTURAL ENGINEER
<br /> REGISTERED IN THE STATE OF WASHINGTON. CONTRACTOR TO PROVIDE SOIL �� �TRANSFORMER DETAIL REFERENCE CU COPPER SLV SLEEVE
<br /> ANALYSIS AS REQUIRED. OQ CCN CAMERA, PAN/11LT/ZOOM �W� M
<br /> D DATA SM SINGLEMODE
<br /> (� TRANSFORMER, CURRENT DETAIL REFERENCE W/ORIGINATING SHEET REFERENCE DED DEDICATED
<br /> SPECS SPECIFICAl10NS
<br /> � LIGHT POLE BASE DETAIL � TRANSFORMER, MAGNETIC CORE SHOWN DEV DEVICE SW SWITCH
<br /> E0.00 SCALE:NONE SECTION REFERENCE DN DOWN
<br /> � SWBD SWITCHBOARD
<br /> OA AMMETER DW DISHWASHER
<br /> TELECOM TELECOMMUNICATIONS
<br /> OC CONTACTOR SECTION REFERENCE W/ORIGINAl1NG SHEET REFERENCE EWC ELECTRIC WATER COOLER TGB TELECOMMUNICATIONS GROUNDING
<br /> � FA FIRE ALARM BUSBAR
<br /> OK KEY INTERLOCK �e� FB FLOOR BOX TMGB TELECOMMUNICAl10NS MAIN
<br /> ��t# ELEVAl10N REFERENCE
<br /> OM METER FBOIC FURNISHED BY OTHERS, INSTALLED GROUNDING BUSBAR
<br /> PM POWER METER � PROJECT NORTH REFERENCE BY CONTRACTOR TSER TELECOMMUNICAl10NS SERVICE
<br /> a D FI FILM ILLUMINATOR ENTRANCE ROOM
<br /> OR RELAY N`���� FO FIBER OPT1C(AL) N TELEVISION
<br /> �� v PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE FOC FACE OF COLUMN TYP TYPICAL
<br /> � RELAY, GFI a D Revisions
<br /> �Q� NEW WORK G,GND GROUND UF UNDER FLOOR
<br /> � SURGE PROTECTIVE DEVICE GD GARBAGE DISPOSAL UG UNDER GROUND DOC REL 01 06/o�/�s
<br /> EXISTING GFI,GFCI GROUND FAULT CIRCUIT UON UNLESS OTHERWISE NOTED
<br /> EXISTING VIRTICUS VENTURA 1 DOC REL 02 09/21/16
<br /> WIRELESS SITE MANAGER _ _ _ _ _ INTERRUPTER UTP UNSHIELDED TIMSTED PAIR
<br /> �LITY PLANT � FUTURE
<br /> HH HAND HOLE V VOLT OR VOICE
<br /> CONTROL ROOM �XxXx REMOVE EXISTING ELECTRICAL EQUIPMENT HP HORSEPOWER VEL VERIFY EXACT LOCATION
<br /> I I IDF INTERMEDIATE DISTRIBUTION W WIRE, WATT, OR WALLPHONE
<br /> I I LED FIXTURE HEAD
<br /> LED DIMMING BALLAST FRAME/FACILITY WAP WIRELESS ACCESS POINT
<br /> I I SUPPLIED WITH FlXTURE IH INSTA—HOT WATER DISPENSER � WEATHERPROOF
<br /> J—BOX JUNCTION BOX XFMR TRANSFORMER
<br /> I I VIRTICUS RIALTO MAG MAGNETIC � PHASE
<br /> I I CONTROLLER MOUNTED MCC MOTOR CONTROL CENTER
<br /> IN LIGHT POLE
<br /> I I LIGHT POLE
<br /> � — — — — �
<br /> 277—VOLTS
<br /> FROM UTILITY
<br /> PLANT
<br /> No�: DRAWING LIST
<br /> 1. PROVIDE ONE RIALTO CONTROLLER PER POLE. LIGHTING FIXTURE SCHEDULE
<br /> 2. INCLUDE DAY OF COMMISSIONING WITH MANUFACTURER�S REPRESENTATIVE ON SITE. E0.00 SYMBOLS, ABBREVIATIONS, DRAWING LIST, FIXTURE SCHEDULE, DETAILS
<br /> I.AMP INPUT E1.00 OVERALL ELECTRICAL SITE PLAN
<br /> ALTERNATE # CODE WATTS E1.20 ELECTRICAL SITE DEMOLITION PLAN
<br /> TYPE DESCRIPTION MANUFACTURER MANUFACTURERS E1.21 I I P
<br /> L10 POLE MOUNTED SINGLE-HEAD COOPER INVUE VXM AS APPROVED 6 21 lED 146 E2.00 R A POWE RIS R DI RA , ANEL CHEDUL S 0 SUM ARY 1
<br /> LEO CUT-OFF LUMINAIRE, SERIES LIGHT BARS
<br /> NOMINAL 22.5"X 16"X 8",WITH NORTH SITE
<br /> SPECULAR ALZAK REFLECTOR.
<br /> � EXPANDED PARKING - WIRELESS LIGHTING CONTROL DETAIL TYPE III UGHT DISTRIBUTION.
<br /> EO.00 SCALE:NONE PHILIPS ADVANCE DIMMING
<br /> �� �"'��""'','4�,��
<br /> BALLAST FOR MINIMUM 150
<br /> WATTS.2Q'HIGH,ROUND, R='��'� ' '�
<br /> TAPERED;ALUMINUM POLE. ,
<br /> MANUFACTURER'S STANDARD �������� ������� ������
<br /> FINISH AS SELECTED BY ���r�`��
<br /> ARCHITECT.
<br /> 1815 13th Street
<br /> L1flA SIMILAR TO L10 EXCEPT WITH COOPER INVUE VXM AS APPROVED 6 21 LED 292 Everett, Washington 98201
<br /> DUAL HEADS AND MOUNTED ON SERIES LIGHT BARS
<br /> EXISTING PO�E.TYPE IV LIGHT PER
<br /> DISTRIBUTION. FIXTURE Drawing Title
<br /> �106 SIM�LAR TO L10 EXCEPT COOPER INVUE VXM AS APPROVED 6 21 LED 146 SYM BOLS�
<br /> MOUNTED ON EXISTWG POLE. SERIES LIGHT BARS ABBREVIATIONS�
<br /> PER
<br /> FIXTURE DRAWING LIST,
<br /> L10C SIMILAR TO L10 EXCEPT W1TH COOPER INVUE VXM AS APPROVED 6 21 LED 292 F IXTU RE
<br /> 1 DUAL HEADS.TYPE IV LIGHT SERIES LIGHT BARS
<br /> D{STR1BUTtON PER
<br /> FIXTURE � �
<br /> L20 ROUND, ILLUMINATED STAINLESS FORMS+SURFACES AS APPROVED 1 17W 17 D ETAI LS
<br /> STEEL BOLLARD WITH 360 CUSTOM
<br /> DEGREES BUBBLES TYPE SHIELD. LED LIGHT
<br /> ENGtNE,
<br /> 4000K
<br /> COLOR ��� � � � �
<br /> \��OF WAS�I��`
<br /> L30 C�MPACT FLOODLIGHT WITH BEGA COMPACT AS APPROVED 1 73.5V1�'LED 83
<br /> WIDE BEAM. MOUNT TO BEGA FLOODLlGHT#77 797 LUMINAiRE � �' ��. �� ��
<br /> POLE CAP#70 249 ON 30"HIGH. 3" � �' �� � � ��
<br /> DIAMETER ROUND, STRAIGHT,
<br /> STEEL POLE WITH 3-BOLT � �
<br /> ANCHOR BASE. POLE FINISH �,�, � 38180 ��
<br /> COLOR TO MATCH BEGA POLE �r��s�1 ST� ��
<br /> CAP AND FIXTURE HOUSING s�ONAL �
<br /> I '��r���
<br /> J M09 EXI TING METAL HALIDE MS250! 295
<br /> Q FIXTURE ON 20'POLE.TYPE IV HOR/PS
<br /> � LIGHT DISTRIBUTION. Date: 21 SEPTEMBER,2016
<br /> 5,
<br /> m
<br /> � M09A EXISTING METAL HALIDE 1 MS250! 295 Job No: S23257
<br /> rn FIXTURE ON 20'POLE.TYPE III HOR/PS
<br /> r�i LIGHT DISTRIBUTION.
<br /> Drawn By:
<br /> co
<br /> o Checked By: MDJ
<br /> N
<br /> N
<br /> d
<br /> cn Drawing No.
<br /> 0
<br /> 0
<br /> 0
<br /> w
<br /> /
<br /> �
<br /> m
<br /> I
<br /> 0
<br /> Q
<br /> %
<br /> r�
<br /> co
<br /> c�
<br /> rn
<br /> � �
<br /> �
<br /> 0
<br /> N
<br /> /W
<br /> >
<br /> �
<br /> U
<br /> %
<br /> � DOC REL 02
<br /> 0
<br /> N
<br /> /
<br /> �
<br />
|