My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4512 FOREST DR CINGULAR WIRELESS ANTENNA 2019-02-06
>
Address Records
>
FOREST DR
>
4512
>
CINGULAR WIRELESS ANTENNA
>
4512 FOREST DR CINGULAR WIRELESS ANTENNA 2019-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2019 9:04:08 AM
Creation date
2/6/2019 9:04:05 AM
Metadata
Fields
Template:
Address Document
Street Name
FOREST DR
Street Number
4512
Tenant Name
CINGULAR WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> EQUIPMENT CHASSIS! (2)3/8"0 SS HEX NUT HYLUG CONNECTOR INSTALLATION <br /> GROUNDING BUSS BAR! INSTRUCTIONS: ,••-,.....00_• <br /> CABLE RACEWAY (#2)TWO HOLE 1. SELECT PROPER HYLUG FOR THE WIRE SIZE USED. at&t <br /> COMPRESSION LUG 2. STRIP CABLE OF INSULATION TO A LENGTH EQUAL `,...---:-..p, <br /> GROUND WIRE STUD(TYP OF 2 @ TO THE BARREL OF THE CONNECTOR. Your world.Delivered. <br /> NO-LOX ANTI-OXIDIZING I.. FRONT AND BACK OF CABINET) 3. INSERT CABLE FULLY INTO CONNECTOR. <br /> COMPOUND II I 4. APPLY THE PROPER NUMBER OF CRIMPS AS <br /> IIS SHOWN BY NUMBER OF COLORED BANDS. <br /> CLEAR HEAT SHRINK ON 5. CRIMP FROM TONGUE END OF CONNECTOR =PLANS PREPARED BY: <br /> It COMPRESSION LUGSTOWARD CABLES FOR TERMINALS AND CENTER <br /> #2 STRANDED GREENSPLICE TOWARD CABLE FOR BUTT SPLICES ENO IIV�I�.me.3/8'0 STAR WASHER REQUIRING MORE THAN ONE CRIMP PER END. �• CNOrN C6RIN0.INC. <br /> INSULATED COPPER GROUND <br /> ` LEAD TO BUSS BAR OR#2 HYLUG TYPE YGA CONNECTOR IS PRE FILLED WITH 16928 WOODINVILLE REDMOND RD NE,SUITE 210 <br /> SOLID BARE TINNED COPPER PENETROX COMPOUND AND STRIP SEALED. WOODINVILLE,WA 98072 <br /> 732 <br /> PLAN TO(E)GROUNDING SYSTEM EMAIL:HcONE�4 � <br /> rgr.00m <br /> BURNDY HYDRAULIC DIE SET#U1CRT-1/U11T. WWW.CORNERSTONE-ENGR.COM <br /> NOTE: =PROJECT INFO: <br /> FOR GROUNDING CONNECTIONS TO PAINTED CABINETS <br /> CHASSIS,GRIND OFF ALL ENAMEL COATINGS TO BARE METAL WA6450 <br /> AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG <br /> CONNECTION.APPLY NO-LUX TO ALL EXPOSED BARE METAL <br /> FOREST PARK <br /> 4512 FOREST DRIVE <br /> NOT USED 12 NOT USED ii GROUND LUG CONNECTION ^ EVERETT,WA 98203 <br /> y SNOHOMISH COUNTY <br /> 22x34 SCALE:NTS 111x17 SCALE:NTS 22x34 SCALE:NTS 111x17 SCALE:NTS 22x34 SCALE:NTS 111x17 SCALE:NTS <br /> F.-ISSUED FOR: <br /> GROUND BAR ATTACHMENT: COAXIAL GROUND KITS W/ <br /> Li CONSTRUCTION <br /> LONG BARREL COMPRESSION <br /> CONCRETE SUBSTRATE: (4)3/8"0 HILTI TZ EXPANSION ANCHORS DOUBLE LUGS,ATTACH TO ._REV:-DATE:-ISSUED FOR: BY._ <br /> WITH 2"MINIMUM EMBEDMENT. GROUND BAR&INSTALL BY <br /> ANTENNA CONTRACTOR <br /> WOOD FRAMED SUBSTRATE: (4)3/8"0 LAG SCREWS WITH 2"MINIMUM (CADWELD TYPE-GL) <br /> EMBEDMENT(ADD BLOCKING IF � <br /> NECESSARY. [v t 02-13-18 FINAL DMO <br /> CLEAR HEAT SHRINK 4"x 24"x 1/4"THK COPPER <br /> SOLID CMU WALL: (4)3/8"0 HILTI TZ EXPANSION ANCHORS ON COMPRESSION LUGS GROUND BAR INSTALLED & 02-08-18 REVISED JRF <br /> WITH 2"MINIMUM EMBEDMENT. BY GENERAL CONTRACTOR <br /> HOLLOW CMU WALL: (4)3/8"0 HILTI HIT HY-20 WITH HIT-AI 0 01-09-18 PRELIMINARY DMO <br /> STANDARD RODS.(3 3/8"EMBEDMENT) 000000 • 000 () 000000000 DRAWN BY:=CHK.: APV.: <br /> 000000000000000000• <br /> NOTE: • • �* DMO .I MWO I MWO <br /> PROVIDE ELECTRICAL ' •� i 0 0 0 0 0 0 0 O O 0 0 0 0 0 0 O •�2: ` <br /> COAT ALL MECHANICAL CONNECTIONS ISOLATORS Q % 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 •%%; <br /> CURRENT ISSUE DATE <br /> W/"NO-LUX"OR APPROVED EQUAL CONNECTION(TYP) <br /> o ' I 0 02-13-18 <br /> I 24" I <br /> _LICENSURE: <br /> FIELD VERIFY <br /> #2 SOLID BARE TINNED cSL,O <br /> COPPER WIRE CADWELD(TYPE-GL) �Qca� • <br /> TYPICAL GROUND BUSS BAR CONNECTIONS 7 ,`� <br /> 22x34 SCALE:NTS 111x17 SCALE:NTS WS f l3 <br /> •••••t =JURISDICTIONAL APPROVAL: <br /> •- •. air • .%� <br /> il <br /> Il <br /> 11 <br /> •r M-i•;; TYPE GL LUG <br /> TYPE GR 1 <br /> .�\ TYPE PT ri =DRAWING INFORMATION: <br /> = • re <br /> DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> �III� -----..i: ALL DIMENSIONS AND ADVISE CONSULTANTS OF MY <br /> •'. —� EF THIS <br /> DRORS AG D ARES SSIONS.ALL PREM USAT S T ES ISION.ilir ��// DRAWkNG ARE SUPERSEDED BY THE LATEST REVISION.—� THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br /> .••', IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE <br /> ,i 14 <br /> - OTHER THAN WH CIS TLY RELATED <br /> BITO NAMED CLIENT IS <br /> STRITYPE GT TYPE SS ,••• -DRAWING TITLE. <br /> TYPE VS <br /> GROUNDING DETAILS <br /> NOTE: <br /> CADWELD TYPES"SHOWN ABOVE ARE EXAMPLES-CONSULT p��+ -DRAWING NUMBER <br /> WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS <br /> TO BE USED FOR THIS PROJECT. <br /> E-1 . 1 0 <br /> CADWELD DETAIL 4 NOT USED 3 NOT USED .) <br /> 22x34 SCALE NTS I11x17 SCALE:NTS 22x34 SCALE;NTS 111x17 SCALE NTS 22x34 SCALE NTS I11x17 SCALE NTS CEI JOB NUMBER: LTE 3G 4C 17-09125 <br />