Laserfiche WebLink
• Interior Lighting Summary - Building Area Method LTG-INT-BLD <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address Toggles Bottle Shop Date 9/15/2014 <br /> Lighting Alterations, Renovations &Building Additions For Building Department Use <br /> 0 Less than 60% 0 60%or more 0 Stand alone 0 Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance.Refer to C101.4.3. <br /> b.For retrofits and building additions,provide Building Area types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Building Area types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d. If less than 60%of existing fixtures will be replaced, use LTG-INT-SPACE form. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, Allowed Gross Interior Watts Allowed <br /> Building Area* room#,or ALL) Area Description Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Dining: Bar A2.1 Entry/Dining/Bar 0.99 991 981 <br /> lounge/leisure <br /> Retail A2.1 Retail 1.33 622 827 <br /> Warehouse A2.1 Storage 0.50 403 202 <br /> Office A2.1 Office/Break 0.90 270 243 <br /> * Select Table C405.5.2(1)Building Area from drop down menu. Total 2286 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts/ Watts <br /> Building Area* room#) Fixture Description** Fixtures Fixture Proposed <br /> Dining: Bar A2.1 14F "� i�a�. p 30 30 900 <br /> lounge/leisure t !/ /t, <br /> Retail A2.1 Fluorescent 7 60 420 <br /> Warehouse A2.1 Flourescant 3 40 120 <br /> Office A2.1 LID/track 3 40 120 <br /> * Select Table C405.5.2(1)Building Area from drop down menu. <br /> **Include existing to remain lighting and exempt lighting equipment per notes below. <br /> Compliance by Building Area <br /> Total Allowed Total Proposed Interior Lighting Power <br /> Building Area Warnings Watts Watts Allowance <br /> Dining: Bar 981 900 COMPLIES <br /> lounge/leisure <br /> Retail Confirm all fixtures are reported under proposed lighting-low watts 827 420 COMPLIES <br /> relative to maximum allowed. <br /> Warehouse Confirm all fixtures are reported under proposed lighting-low watts 202 120 COMPLIES <br /> relative to maximum allowed. <br /> Office Confirm all fixtures are reported under proposed lighting-low watts 243 120 COMPLIES <br /> relative to maximum allowed. <br /> Total 2253 1560 <br /> Notes: <br /> 1.Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between <br /> Building Area types is not allowed under the Building Area Method compliance path. <br /> 2.Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. <br /> 3.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8), number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp, and ballast information. <br /> 4.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting,list the greater of actual luminaire wattage or length of track multiplied by 50, / <br /> or as applicable,the wattage of current limiting devices or of the transformer.For low voltage track lighting list the transformer rated wattage. 0 <br /> 1 <br /> 5.For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. <br /> 6.Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures.Identify as existing in fixture description. <br />