My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1620 W MARINE VIEW DR LOMBARDIS 2018-01-02 MF Import
>
Address Records
>
W MARINE VIEW DR
>
1620
>
LOMBARDIS
>
1620 W MARINE VIEW DR LOMBARDIS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2022 10:03:01 AM
Creation date
2/7/2019 9:11:52 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1620
Tenant Name
LOMBARDIS
Notes
LOMBARDIS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />All kitchen exhaust hoods, Type I & 11 <br />• Plans should show that the kitchen exhaust canopy -type hood extends a minimum 6 <br />inches beyond the cooking surface on all open sides in compliance with Section 508.6 <br />• The kitchen exhaust should have make-up air supplied to the room equal to the <br />amount to be exhausted The make-up air system should be interlocked with the <br />exhaust system. Section 402.4 <br />• tchen exhaust systems should be provided with approved fire -extinguishing <br />equipment. Section 509.2 <br />The vertical distance between canopy -type hood and cooking surface should not <br />exceed 4 feet. Section 508.6 <br />Type I hoods only <br />A solid fuel charbroiler should be provided with a separate exhaust system, <br />independent of all other systems serving other cooking appliances. Section 508.7.1 <br />Kitchen ventilation duct gage for a Type I hood should be at least No. 16 gage steel or <br />No. 18 gage stainless steel. Hoods should be No. 22 gage steel. Sections 507.3 & <br />508 <br />Kitchen ventilation duct should slope not less than 1/4 inch per lineal floor in 12 units <br />horizontal (2% slope) toward the hood where the duct length does not exceed 75 feet. <br />Section 507.4 <br />Cleanout locations should be indicated on the exhaust duct. Section 507.5 <br />�,• The kitchen exhaust duct should be enclosed in at least a one -hour shaft (or two-hour <br />shaft in Type I or Type II FR buildings). Section 507.6 <br />The duct enclosure should be sealed around the duct at the point of penetration and <br />vented to the exterior at the point of termination. Section 507.6 <br />The shaft should be separated from the duct by at least 3 inches and not more than 12 <br />inches and should serve a single grease exhaust system. Section 507.6 <br />The size of the kitchen exhaust hood and duct, and the fan's cubic -feet -pet -minute <br />(L/s) rating, should be provided to allow for the review of air quantities and <br />velocities in the duct to ensure compliance with Sections 507.8 & 507.9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.