2714 COLBY AVE 2017 ROMIOS PIZZA Plans 2022-12-02
>
Address Records
>
COLBY AVE
>
2714
>
ROMIOS PIZZA
>
Plans
>
2714 COLBY AVE 2017 ROMIOS PIZZA Plans 2022-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2022 9:15:22 AM
Creation date
2/7/2019 11:17:49 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2714
Tenant Name
ROMIOS PIZZA
Permit
B1704-053
Year
2017
Notes
TI FOR NEW RESTURANT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GLASS AND GLAZING <br /> 3. Outboard panes in insulating glass units or multi- tempered or heat-strengthened glass and shall comply with <br /> ple glazing where the bottom exposed edge of the Category II or CPSC 16 CFR Part 1201 or Class A of ANSI <br /> glass is 25 feet (7620 mm) or more above any Z971. Glazing in railing in-fill panels shall be of an <br /> grade, roof, walking surface or other horizontal approved safety glazing material that conforms to the provi- <br /> or sloped(within 45 degrees of horizontal) (0.79 sions of Section 2406.1.1.For all glazing types,the minimum <br /> rad) surface adjacent to the glass exterior. nominal thickness shall be'/4 inch(6.4 mm). <br /> 2406.4.4 Glazing in guards and railings. Glazing in Exception: Single fully tempered glass complying with <br /> guards and railings, including structural baluster panels Category II of CPSC 16 CFR Part 1201 or Class A of <br /> and nonstructural in-fill panels, regardless of area or ANSI Z97.1 shall be permitted to be used in handrails and <br /> height above a walking surface sha11 be considered a haz- guardrails where there is no walking surface beneath them <br /> ardous location. or the walking surface is permanently protected from the <br /> 2406.4.5 Glazing and wet surfaces. Glazing in walls, risk of falling glass. <br /> enclosures or fences containing or facing hot tubs, spas, 2407.1.1 Loads.The panels and their support system sha11 <br /> whirlpools, saunas, steam rooms, bathtubs, showers and be designed to withstand the loads specified in Section <br /> indoor or outdoor swimming pools where the bottom 1607.8.A design factor of four shall be used for safety. <br /> exposed edge of the glazing is less than 60 inches (1524 <br /> mm) measured vertically above any standing or walking 2407.1.2 Support.Each handrail or guard section shall be <br /> surface shall be considered a hazardous location. This supported by a minimum of three glass balusters or shall <br /> shall apply to single glazing and all panes in mulriple glaz- be otherwise supported to remain in place should one bal- <br /> ing. uster panel fail.Glass balusters shall not be installed with- <br /> out an attached handrail or guard. <br /> Exception: Glazing that is more than 60 inches (1524 <br /> mm),measured horizontally and in a straight line,from Exception: A top rail shall not be required where the <br /> the water's edge of a bathtub,hot tub,spa,whirlpool or glass balusters are laminated glass with two or more <br /> swimming pool. glass plies of equal thicl�ess and the same glass rype <br /> 2406.4.6 Glazing adjacent to stairways and ramps. �'�'hen approved by the building official. The panels <br /> Glazing where the bottom exposed edge of the glazing is shall be designed to withstand the loads specified in <br /> less than 60 inches(1524 mm)above the plane of the adja- Section 1607.8. <br /> cent walking surface of stairways, ]andings between 2407.1.3 Parl�ng garages.Glazing materials shall not be <br /> flights of stairs and ramps shall be considered a hazardous installed in handrails or guards in parking garages except <br /> location. for pedestrian areas not exposed to impact from vehicles. <br /> Exceptions: 2407.1.4 Glazing in wind-borne debris regions.Glazing <br /> 1. The side of a stairway,landing or ramp that has a installed in in-fill panels or balusters in wind-bome debris <br /> guard complying with the provisions of Sections regions shall comply with the following: <br /> 1015 and 1607.8, and the plane of the glass is 2407.1.4.1 Balusters and in-fill panels.Glass installed <br /> greater than 18 inches(457 mm)from the railing. in exterior railing in-fill panels or balusters shall be <br /> 2. Glazing 36 inches (914 mm) or more measured laminated glass complying with Category II of CPSC <br /> horizontally from the walking surface. 16 CFR Part 1201 or Class A of ANSI Z97.1. <br /> 2406.4.7 Glazing adjacent to the bottom stairway land- 2407.1.4.2 Glass supporting top rail. When the top <br /> ing. Glazing adjacent to the landing at the bottom of a rail is supported by glass, the assembly shall be tested <br /> stairway where the glazing is less than 60 inches (1524 according to the impact requirements of Section <br /> mm) above the landing and within a 60-inch (1524 mm) 1b09.1.2. The top rail shall remain in place after <br /> horizontal arc that is less than 180 degrees(3.14 rad)from �pact. <br /> the bottom tread nosing shall be considered a hazardous <br /> location. <br /> SECTION 2408 <br /> Exception: Glazing that is protected by a guard com- GLAZING IN ATHLETIC FACILITIES <br /> plying with Sections 1015 and 1607.8 where the plane <br /> of the glass is greater than 18 inches(457 mm)from the 2408.1 General.Glazing in athletic facilities and similar uses <br /> guard. subject to impact loads, which forms whole or partial wall <br /> 2406.5 Fire department access panels. Fire department sections or which is used as a door or part of a door, shall <br /> comply with this section. <br /> glass access panels shall be of tempered glass.For insulating <br /> glass units,all panes shall be tempered glass. 2408.2 Racquetball and squash courts. <br /> 2408.21 Testing. Test methods and loads for individual <br /> SECTION 2407 glazed areas in racquetball and squash courts subject to <br /> GLASS IN HANDRAILS AND GUARDS impact loads shall conform to those of CPSC 16 CFR Part <br /> 1201 ar ANSI Z97.] with impacts being applied at a <br /> ' 2407.1 Materials. Glass used in a handrail, guardrail or a height of 59 inches (1499 mm) above the playing surface <br /> guard secrion shall be laminated glass constructed of fully to an actual or simulated glass wall installation with fix- <br /> 546 2015 INTERNATIONAL BUILDING CODE° <br />