I .
<br /> 1
<br /> ,
<br /> -/� , NOTE: CONTINUOUS CAULKING
<br /> V � `' INT. ~ �' E�CT. INT. � ' /� � � � �� � i ' AT TOP & BOTTOM OF GWB.
<br /> , . I �. I ��,,\\ �i�T. EXT. INT. 1 � � EXT_ �I�1T . E3�'. cwe ro Rurv CONTINUOUS
<br /> d Q � d a NOTE: CONTINUOUS CAULKfNG a BEHIND ALL TUBS.
<br /> INT. � EXT. � : s ��`�' ; �, l`.� i,r—BRICK VENEER GROUTED TO AT TOP & B07TOM OF GWB. I
<br /> � CEMENT BOARD, COLOR AND
<br /> Q Q Q _ ' '\�� �`. �,� il �" � _�---- `�---- PIPE WHERE OCCURS>
<br /> � � � 4 �;. CEMENTIT�OUS SIDING � { ,./��/ � ,� � Q .�'� P,Afi�'ERN PER ARCHITECT j. a �' CAST-IN--PLACE CONCRETE �i --`-�-��"�� � � WRAP PIPE W/ 3 i/2"
<br /> a � � �,�\ P{�EFAB. PANEL BELOW �
<br /> MTL CHANNEL � 16 O.C. PER STRUCTURAL; WITH � Ll FIBERGLASS SOUND
<br /> � / GRAQE WALL DRAINAGE � � � � a �.._
<br /> I i' � a WATER REPELLANT COATING ATTENUATION BATr AS
<br /> {SECURE TO C4NC.) Q � - ��� �Y���� . CEMENT B�Q,4RD i ._ , a � a REQUIRED
<br /> a a �} �j� ..,....i`
<br /> I �� � BENTONITE PANE€� !' „ ,� ,� � S _- CAST-IN-PLACE
<br /> � '�\���WATEftf'R4QFiNG
<br /> a. a ; ' � � ' �r '" -3- / p, L C S D �y CONCRETE; WITH WA7ER
<br /> 5 8 STEE T
<br /> L]° .� �q� a I � a " � '!�i� �'�----�-�-FREE DRAl�1lNG GRANI.lLAR qQ a .-�-WEATHER RESISTANT BARRIER -� _ � a AT 24 O.C. & 1/2" `----�� � REPELL4NT COATING
<br /> ,
<br /> WATERPROOFING MEMBRANE � �,�� /� gAC14FILL MATERIAL OR ,{ (W��) � � THEi�MAL BREAK % � '
<br /> � � � Q I � -5-1/2" STEEL C STUDS �9..-�
<br /> v � - -- ��� GYP. SHEATHING � � �j� �! STRIF 0�' DRAfNAGE MAT �-----� � >, � ,-�'. ;
<br /> � /� a AT 24' O.C. & 1/2 � -�"
<br /> � f/�� � THERMAL BREAK � �
<br /> � �, I q / ! � 2-1/2 RIGID INSU'LAT10N 2-1/2" RIGID .
<br /> a Q a � � ., a � ��.'�� LAGGII�G Q Q WHERE OCCIlRS a � ° 2-1/2" POLYSTYRENE �w '�' `'
<br /> � 1NSU�ATiON � 4 �'`' �
<br /> `� _�.�' .i � ; �;� '; � � a � � � INSULATION
<br /> a - --- CONCRETE 4 -� -- -� CONCRETE � +�. . �
<br /> �
<br /> � / �._--.-�—CAST !N PLACE ____---1/2" AIR SPACE TYP. � 5/8 GWB � " , �l � `
<br /> � 1 5�8 GWB "
<br /> COI�CRETE PER � ��� , :
<br /> �1 a : -
<br /> � �, � ; r��� sT�ucru�,,� ��a�s a : :� :
<br /> / ` o a --._--- I
<br /> � �. � a a. a � ���� � . a. - - ^ a ',�F�,.��.. ���1 ,
<br /> ' --� , ��?,:# ������-��
<br /> ASSEMBILY: fBC TABLE 720.1.(2) ASSEMBLY: 1BC TABLE 720.1.(2) ASSEMBLY: IBC TABLE 720.1.(2) ASSEMBLY: IBC TABLE 720.�.(2) ASSEMBLY: IBC TABLE 720.1.(2) � � ASSEMBLY: IBC TABLE 720.1.(2) � .��
<br /> FIRE TEST: F'IRE TESL , VARIES �, VARIES FIRE TEST: FIRE TEST: �r � ���' � �A�I�� " F1RE TEST: � VARIES � VARIES ,� FIRE TEST:
<br /> r i; "`
<br /> �C8 EX�RIQR WALL � STAIR DOOR VMfAY 1�I/'�, //�'�/l EXTERl�R — //�' EXTERI � -- BELOW GR�,DE ��■�T� ■�1- 3 HR -- GONCRETE � EXTERIOR — STAIR & ELEVATOR //'�_ 3 HR — CONCR�TE � EXTERIOR — TENANT SPACE � HR — CONCRETE � EXTERIOR
<br /> >�_ » ,Y , V I fr r r �V� v t• 1 V� n r n ��+� n v r� ��� � o ee
<br /> � �1 -0 3 =1 -U' 3"=1'-0 3 =1 -0 3 =1 -0 3'=1 -0
<br /> NOTE: GONTINUOUS CAULKING �
<br /> 4Y � ^ TOP & BOT�'OM OF GWB. GWB TO RUN
<br /> � . CONT�, BEHIND ALL TUBS. SEE STRUC.
<br /> INT � E�4T. INT. ; � EXT. INT. EXT. DWGS. FOR SHEAR WALL LOCATIONS.
<br /> FLUSH OUT FlNISHES BEYOND 2-HR
<br /> 'a WALL TO N�AREST CORNER, 7YP.
<br /> R-21 FIBERGLASS BATT Q ° ---- 8x8x16 CMU
<br /> INSULATION, FRICTION-FIT ° EXTERIOR GWB SHEATHING
<br /> -_-_.-� � :,
<br /> — MTL CHANNEL � 16" O.C. ° ! -- MTL CHANNEL � i 6" Q.C.
<br /> (SECURE TO STUD) °. (SECURE TO STUD)
<br /> �`"��������` `' WEATHER RESISTANT BARRIER �
<br /> A
<br /> ''f� � ° ° — MTL STUDS
<br /> � WRB
<br /> � -�_
<br /> �—(2) LAYERS 5/8" TYPE 'X' GWB a R-19 FlBERGLASS BA1T
<br /> �. a ° ° 3/8" GROUT INSULATION, FRICTION-FIT
<br /> .,,,���, �a
<br /> MTL STUDS AT 16" O.C. � . 5/8" GYP. SHEATHING �
<br /> ■ �.o
<br /> 5/$" TYPE 'X' GWB (MR � �
<br /> 4" METAL STUD BATHROOMS) W/ PVA PRIMER
<br /> ----(2) LA'YERS 5/8" GYP. SHEA7HING PAINT �
<br /> � — RIGID INSUILATION '�-- CEMENTITIOUS SIDING � �
<br /> 4 � �
<br /> ALIGN EDGE OF GWB WlTH GRID __._.._..._._._._._...._..___ � �__ ��2» �WB ---- ALIGN EDGE OF GWB WITH GRID
<br /> I' d � �
<br /> ASSEMBLY: GA WP1522 ASSEMBLY: IBC TABLE 720.1.(2) � �f�,: ; ASSEMBL:Y: GA WP 1072 (SIM)
<br /> FIRE TEST; WHI-495-0236 �r � FfRE TEST: FM WP-45
<br /> 6-19-68
<br /> SOUND TEST:NRCC 818-NV SOUND TES7: NRCC 816-NV9 � � i
<br /> 2 HR — SHAFT C� EX�RIOR �—�—s� � 3 F�R -- EXTERIOR WALL � GAi R�G 1 HR — EXTERIOR VIsALL 2—�—�� � �
<br /> 3"=1'-0" STC: _55-59 3"=��-0�� WTD1 3„-1,_�„ STC: 45 TO 49 � � o
<br /> � �
<br /> � s �
<br /> � � �
<br /> t7 � � r� i '
<br /> Z > �
<br /> ao � � �,.. I
<br /> � • .. •� • � •• • -_-BRICl: t,fE^�EER �ROE:TED T� �j ¢ � � r � � l
<br /> -� � Q o � �-
<br /> .w c�i csy �
<br /> I NT� EXT. � C EM ENT BOARD i NT � ... I EXT. I NT EXl'. � � � � � �
<br /> � ---CEMENT BOARD ' - PL"YWOOD PER STRUCTURAL � � � � �
<br /> ��_,_.. 2X WD STUDS PER STRUCT. _ �_r p � � � N N
<br /> 2 X W D S T U D S P E R S T R U C T. f .�--- MTL CHANNEL � 16" O.C. 1--�1'—C E M E N T I T I O U S S I D I N G
<br /> (SECURE T�J STUD)
<br /> MTL CHANNEL � 16" O.C. MTL CHANNEL � 16" O.C.
<br /> (SECURE TO STUD) --- (SECURE TO STUD)
<br /> ;
<br /> -�_�� R-21 FIBERGLASS THERMAL �I.' NSULATIONRW/ S VAPOR MBARRIER ��PER ST�RUCTUR DS
<br /> INSULATION W/ VAPOR BARRIER {2) LAYERS 5/8" GYP SHEATHING ---WEATHER RESISTANT BARRIER
<br /> _�_�--�-�(2) 'LAYERS 5/8" TYPE "X` GWB
<br /> �
<br /> �(2} LAYERS 5/8" GYP. SHFATHING (2) LAY�RS 5/8" TYPE 'X' GWB 5��� GYP. SHEATHING
<br /> -WEATHER RESISTANT BARRIER
<br /> -5/8" TYPE 'X' GWB (MR �
<br /> �-1 1/2" AIR SPACE TYP. — WEATHER RESIS7A'NT BARRIER BATHROOMS) W/ PVA PRIMER
<br /> PAI NT
<br /> �
<br /> ' � :_ . � �.�-�-- CEMENTITIOUS SIDING �-- R-21 FIBERGIASS
<br /> R-21 FIBERGLASS THERMAL INSULATION
<br /> ` THERMAL INSULATION
<br /> ASSEMBLY: GA WP 84'10 ASSEMB'LY: GA WP 849 5 ASSEMBLY: ICBO ER-4667
<br /> g,� $r� 6 3/4" � 2.4.3�2
<br /> FIRE TEST: UL R1505-1,2 FIRE TEST: FM WP 360, --�` FIRE TEST: ICBO ER-4776
<br /> 4-22-65 9-27-74
<br /> 2 HR — ALT. EXTERIOR — 'STAIR & EL�I/ATOR 2 HR — SHAFT—EkTERIOR 1 HR — EXTERtOR — � BR CEMENT PANEL (FC �
<br /> VVUTA3 3„_,, Q„ VI�TA2 3„ ,, o» - - -- U�ITA� ��f ,� o�,
<br /> �
<br /> _
<br /> :���� �
<br /> _. _ �������o
<br /> ��������� : �
<br /> �,�_ ��.:—:�
<br /> ��3 ����.
<br /> `��fi����� ;
<br /> �_ �
<br /> Revisions
<br /> PERMIT SUBMITAL
<br /> 5/20/2013
<br /> PERMIT RE-SUBMITl�L
<br /> 9/'i 1/2013
<br /> �� �
<br /> PAGOIDA VtLLAGE
<br /> EVERETT
<br /> (�RAND & WALL STREET
<br /> EVERETT, WA
<br /> NOTE: I. CONTINUOUS CAULKING � TOP & BOTTOM OF GWB.
<br /> 2. GWB TO RUN CONT. BEHIND ALL TUBS. SEE STRUC.
<br /> DWGS. FOR SHEAR WALL LOCATIONS. FLUSH OUT
<br /> FINISHES BEYOND 2-HR WALL TO NEAREST CORNER, Drawing Tifile
<br /> nP� WALL
<br /> 3. RE�'ER TO BU{LDING ENVELOPE CONSUILTANT DWGS
<br /> �OR WA7ERPROOFING �ASSEMBLY INFORMATION.
<br /> A�SEMBL S
<br /> (EX�ERIOR)
<br /> AMENITY
<br /> INSULATION TO CONFORM TO PERSCRIPTIVE PATH OPTION II
<br /> �OR THE SEATfLE C1TY L1GHT "BUILT SMART" REQUIREMENTS.
<br /> GLAZWG U-VALUE (MAX,) .33
<br /> UNGLAZED DOOR U-VALUE �MAX.) �1 g
<br /> A7TIC CEuNG R�"'�9
<br /> VAULTED OR FlAT ROOF CEILING R-30 � '
<br /> WALL ABOVE GRADE R-21
<br /> WALL BELOW GRADE R-21
<br /> Date: Q9 11 2Q 13
<br /> FLOOR ABOVE PT SLAB �-15 JOb NO: -
<br /> I
<br /> UNDER FLOOR R-30
<br /> �
<br /> C: C4NCRETE WALL
<br /> Drawing Na.
<br /> D: METAL WALL
<br /> B: WOOD WALL
<br /> A: EXTERIOR WALL
<br /> -
<br />
|