Laserfiche WebLink
_ <br /> _ <br /> ---L — <br /> o . <br /> . _ > <br /> . SYMBOLS LEGEND —� GENERAL SYMBO�S LEGEND — WIRING DEVICES SYMBO�S LEGEND — POWER SYMBOLS LEGEND �- POWER � <br /> � <br /> . SYMBOL DESCRIPTION SYM80L DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION � <br /> x-x-x-x EXISTiNG T4 BE REMOVED {CROSSED) � TO CL, UON� WAl.L SWITCH MOUNT SWITCHES AT 48" AFF. �� � ; � <br /> Q TRANSFORMER �g ST CIRCUII' BREAKER `� <br /> � HEAVY l.INEWEIGHT INDICATES NEW W4RK $XX WAL! SWITCH - SUBSCRIPT �Y1 ST - iNDICATES SHUNT TRIP <br /> 2 = 2-POLE LV = [.OW-V{3LTAGE rY !'' � <br /> � 1.IGHT LINEWEIGHT IN�ICATES EXISTIN6 INFORMATION 3 a 3-WAY OS � OCCUPANCY SENSOR TYPE � �� a <br /> ` 4 � 4-WAY OP = OCCUPANCY/PHOTOELECTRIC TYPE X-XX-X POLE-MOUNTED TRANSFORMER �"�'� <br /> POINT OF CONNECTiON tPOC) BETWEEN NEW AND - <br /> �-~' EXISTING K � KEYED WP � WEATHERPROOF � � _ <br /> . LOWER CASE LETTER INDICATES SWITCHING GROUP � BREAKER WITH EXTERNAL GROUND FAULT RELAY AND CT , <br /> XX EQUIPMENT IDENTIFIER tXX a ABBREVIATION Y = MOUNT SWITCHES AT +48" AFF. TO CL, UON. o DELTA ' <br /> z <br /> � EQUIPMENT SCHEDULE NUMBER) ANY COMBINATION OF SWITCH i'YPES CAN BE US�D tIE. 3K �? <br /> � 3-WAY KEYED SWITCH} YyYE b � <br /> � - �� �� �! � � CIRCUIT, BREAKER WITH GROUND FAULT PR4TECTI4N � <br /> 1� DRAWING CONSTRUCTION t FLAG ) NOTE �- SINGLE R�CEPTACLE NEMA 5-20R, +18 AF'F U4N 4 w . <br /> � �� RECEPTACLE NEMA 5-20R� *98" AFF UON �� MEDIUM VOLTAGE CABLE TERMINATOR b � <br /> X--XX EQUIPMENT IDENTiFIER M MOTOR--OPERATED CIRCUIT BREAK�R <br /> �T��T TAMPER RESiSTANT RECEPTACLE NEMA 5-20R, {18" AFF UQN �--• �I� LIGHTNTNG ARR�STORS � <br /> XXX RACEWAY/CABLE/CONDUCTOR ROUTING IDENTIFIER- �,. ��„ RECEPTACLE NEMA 5-20R WITH GROUND FAULT CIRCUIT � <br /> REF�R TO RACEWAY/CAB1.E/CONDUCTOR SCHEDUE.E INTERRUPTER, +18" AFF UON �(--�,► SURGE ARRESTORS b ST <br /> --, <br /> . �---- MATCHLINE � SPLIT WIRED DUPLEX RECEPTACLE NEMA 5-2�R, �i8" AFF �_��/� � � . � <br /> UON � „ �J NEUTRAI.. GROUNDING RESISTOR � SWITCH WITH EX?'ERNAL GROUND FAULT RELAY AND CT <br /> � DUPLEX R�CEPTACLE NEMA 5-20R� ISOLATED �ROUND, ti8" } <br /> REVISION CLOUD (ENCIRCLES DRAWING CHANGES MADE A�F UON UM METER <br /> � /� REC�PTACLE NEMA 5-20R, ABOVE CDUNTER. m <br /> � SiNCE THE PREVIOUS RELEASE) --�.7-- MOV SURGE PROTECTION W <br /> RECEPTAC�.E N�MA 5-20R WITH GROUND FAULT CIRCUI€ MICROPROCESSOR CONTRO�LED MONITOR Q <br /> �/� INT�RRUPTER, ABOVE COUNTER. COORQINATE WITH REFER TO SPECIFICATIONS FOR METERING VAI.UES AND R�SISTOR � <br /> CASEWORK SHOP DRAWINGS AND ARCHITECTURAl. DRAWINGS. PROTECTIVE FUNCTI�NS ��- <br /> Q REVISI�N REFERENCE � o <br /> TAMPER RESISTANT RECEPTACLE NEMA 5-20R WITH GROUND -�- FUSE � <br /> T T FAULT CIRCUIT IN7'ERRUPTER A84VE COUNTER. � <br /> �' �� COORDINATE WITH CASEWORi� SHOP DRAWINGS AND CURRENT TRANSFORMER � � 4 �? <br /> ARCHITECTURAL DRAWINGS. � � MOT�R THERMAL OVERL4ADS - (3) UN�ESS OTHERWISE <br /> � X XX DETAIL .REFERENCE RECEPTACLE��NEMA 5-20R, CONNECTEO TO EMERGENCY �� NOTED � � � <br /> DETAIL TDENTIFICATION NUMBER ��� CIRCUIT, }18 AFF UON �� ----{ E--- NORMALLY OPEN CONTACT � _ � <br /> POTENTIAI.. TRANSFORMER � � <br /> SNEET WHERE DETAIL. IS DRAWN R E C E P T A C L E N E M A 5�2 0 R M O U N T E D A B O V E C O U N T E R. : --�/�--- NORMALLY CL.4SED CONTACT . ^� � <br /> r�/� COORDINATE WITH CASEWORK SHOP DRAWINGS ANO I N D I C A T iN G i N S T R U M E N T � w <br /> X ARCHITECTURAL ORAWINGS. AM - AMMETER� VM-VOLTMETER� i FM-FREQUENCY METER� SV --�- SOLENOID VALVE � <br /> � XXXX ELEVATION REFERENCE � P��ENCS PURPOSE RECEPTACLE TYPE AS SHOWN ON � kVAR - KILOVAR METER� kWH-KILOWATT HOUR METER: o <br /> ELEVATION IDENTIFICATION NUMBER kWH/� - KILOWATT H4UR DEMAND METER <br /> SHEET WHERE ELEVATION IS DRAWN �� SINGI.E SERVICE OR COMBINATiON FLUSH FLOOR POKE THRU. � MOTOR-OPERATED VALVE r`�i <br /> � REFER TO FLOOR PLANS FOR DEViCES. INSTRUMENT SWITCH 65a 3 <br /> X SiNGLE SERVICE OR COMBINATION F�USH MOUNTED FLOOR � AS - AMMETER SWITCH� VS - VOLTMETER SWITCH� Q THERMOSTAT <br /> � SECTION REFERENCE �� 80X. REF'ER TO FLOOR PL.ANS FOR �EVICES. ❑ SS - SYNCHRONIZING SWITCHi . � <br /> XXXX SECTION IDENTIFICATION NUMBER SV - SUPERVISORY tLOCAI.-REMOTE) SWITCH ---+p-- TERMINAl. 6LOCK o 0 <br /> S H E E T W H E R E S E C T I O N I S D R A W N '� CETLING-MOUNT£D DUPLEX RECEPTACl.E, NEMA 5-24R - � ,� <br /> !� POWER/COMM PQLE - FLOOR TO CEILING. --{�- SEPARABLE CONNECTOR � � TNDIGATING LIGHT, - TYPE AS NOTED � � � . <br />_ JV A-AMBER� B-BLUE. G-GREEN, R-REO. W-WHITE x � , <br /> � �1 SURFACE MOUNTED FLOOR BOX (PEDESTAI.. TYPE). '� � <br /> " NORTH REFERENCE S2 0-��(�I�- BATTERY <br /> � � C) PUSH BUTTON � � DRAWOUT AC TYPE POWER CIRCUIT BREAKER c."�.� Q <br /> � <br /> . a <br /> - t-- <br /> � <br /> 2 <br /> � <br /> U <br /> t <br /> � <br /> SYMBOLS L.EGEND —. GENERAL SYMBOLS LEGEND — LiGHTING SYMBO�S LEGEND — POWER SYMBOLS LEGEND — POWER � <br /> SYMBOL OESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION � n <br /> � MINTMUM �4" CONDUIT CONCEAI.ED IN CEILING SPACE OR IN XXXX l.IGHT FIXTURE IDENTIFIER - REFER TO E.IGHTING FIXTURE � � � <br /> � WALL MINIMUM ��" WiTH �i2 AWG CONDUCTORS WITH �� SCHEDULE � 2-POSITION SELECTOR SWITCH � 240/12�/48V, 1s�, 3W PANELBOARD � a ' <br /> D E O i C A T E O N E U T R A L E A C H C I R C U i T U N L.E S S O T H�R W I S E SHADING INDICATES tUMINAIRE ON EMERGENCY CIRCUTT � <br /> . NOTED oN PLAN. PRovIDE EQUIPME�NT GROUNDING � OR WITH BATTERY BACKUP BA�l.AST a o z <br /> , C O N D U C?O R S S I Z E D P E R N F P A 7 0. i� � � E Q U I P M E N T C A B I N E T -- T Y P E A S N O T E O <br /> �/�i� F L E X I B L E M E T A L C O N D U I T � 2x4 Fl,UORESCENT . '�� Q j 3-POSITION SELECTOR SWITCH HAND-OFF-AUT�MATIC " <br /> r U <br /> CONOUIT - CONCEAI..ED IN OR UNDER FLOOR �� 1x4 FLUORESCENT a� p� XXX 'y�'w° ���� a <br /> � <br /> CONDUIT - ROUTED UNDERGROUND � 2x2 FLUORESCENT __�i�_ 4N-OFF SELECTOR SWITCH PANELBOARD W� ' �a p � ' <br /> � o <br /> - LOW-VOLTAGE WIRING (CLASS B) � WAL.L MOUNTED FLUt}RESCENT LUMINAIRE �,-�-� 2-CIRCUIT PUSHBUTT�N �, <br /> ---• , o <br /> CONDUIT OR CABLE VERTICAI. DOWN � ENCl.OSED GASKETED F1.UORESCENT LUMINAIRE _t- ���� ,, <br /> a <br /> �'O °- PUSHBUTTON SWITCH MOMENTARY CONTACT �l�� q <br /> ------� CONDUIT �R CABLE V�RTTCAL UP �--�---� STRIP FLUORESCENT C <br /> TRANSFER SWITCH {AUTO) 'o <br /> j CONDUIT STUB -- TERMINATE WITH BUSHIN� OR CAP IF E--�"� STAGGERED-STRIP FLUORESCENT �¢ 0 09/21/2015 <br /> UNDERGROUND O DOWNLIGHT � EQUIPMENT COfVNECTION o <br /> --s s— BREAK LINE � <br /> � - + . }O WAL.L MOUNTED LUMINAIRE � GENERATOR X <br /> SNOHOMFSH COUNTY �; <br /> CONOUIT SEAL p WALL WASH LUM�NAIRE � MOTOR CONNECTION XXXXX AMPERES SHORT CIRCUIT AVAI�ABl.E {SYMMETRICAt.) � . <br /> D � <br /> -�--- EXPANSION FITTIN� EC+ WALL MOUNTE� DIRECTIONAl. LUMINAIRE ,�g�p D , ° <br /> CQ DECORATIVE PENDENT LIGHTING FIXTURE - TYPE AS NOTE� "u' SMOKE DAMPER ��� FEE�ER TAG - REFER TO FEEDER SCHEDULE PU83.IC UTtLI7Y DISTR[CT NO t � <br /> M �S� F'IRE SMOKE DAMPER � � <br /> CABL.E TRAY � TRACK LIGNT - l.ENGTH AS IN�ICATEO ON P1.ANS � � <br /> NUMBER OF LUMINAIRES AS SHOWN WO 354046 � <br /> ,,r-BRANCH CIRCUIT NUMBERS �-o-� POLE-MOUNTED LUMINAIRE � �- OTHERWISE_POLE� NEMA SIZE 1 MiNIMUM UNLESS NOTE� <br /> NUMBER OF LUMINAIRES AS SHOWN ON F'LANS � � � : � T �: ASK � <br /> /� -1,3,5 ` <br /> PANE{� DESIGNATION COMBiNATION STARTER � ELECTRIC;AL _DRAWING INDEX ` � <br /> .oC) IN-GROUND LANDSCAPE LUMINATRE `� : , ' <br /> � . ; ....: , .. .R. .... ... � ......:: . .. . ... : .,. . .::... : . . ,.,,� . , o <br /> HP RATED 3-POI.E NEMA SIZE 1 MINIMUM UNLESS NOTED � <br /> HOME RUN TO SOURCE OF SUPPLY �# ILLUMINATED EXIT SIGN - SINGLE FACE ARROW INDiCATES �' OTHERWIS� - OVE�CURRENT PR4TECTION AS REQUIRED BY S-10A-C122 CONTROL BUILDING ELECTRICAL LEGEND SCALE NONE � <br /> � <br /> . � DIRECTION OF EGRESS, UNIVERSAL MOUNT EQUIPMENT MANUFACTUR�R OR AS NOTED S-'i0A-C123 CONTROt BUILDIN� EL�CTRICAl. LEGEND, ABBREVIATIONS, � <br /> CONOUCT4RS -- CONNECTE� �t ILLUMINATED EXIT SIGN � DOUBL.E FACE ARROW INDTCATES AND GENERAL NO?ES DF7R SAZ/DMD � <br /> DIRECTION OF. EGRESS, UNIVERSAL MOUNT [}, --o�o-- OISCONN�CT SWITCH S--lOA C124 CONTROL BUILDiNG LIGHTING PLAN y <br /> 3-POLE UNLESS NOTED OTHERWISE 4 <br /> -��" CONDUCTORS - NOT CONNECTED S-10A-C125 CON7ROl. BUiLDING GROUNDING PLAN ' CNKR LDS � <br /> Q � BATTERY�POWERED EM�RGENCY WALLPACK FUSED DISCONNECT SWITCH ; <br /> JUNCTION BOX �,,� �. 3--P0�� UNLESS NOTED OTHERWiSE - OVERCURRENT S-14A-C12S CONTROL BUILDING POWER PLAN m <br /> � COMBiNATION BATTERY POWERED EMERGENCY WALLPACK PROTECTION AS REQUIRED BY EQUIPMENT MANUFACTURER S-10A-C127 P0�ROL BUILDING COMMUNICATIONS, FiRE ALARM, & SIGNAL ENGR KWA o <br /> PB PULLBOX - SFZE AS INDICATE€? OR AS REQUIRED BY CODE AND ILLUMINATED EXIT SIGN OR AS NOTED � <br /> M <br /> HH TC TIME CLOCK - TYPE AS NOTED � �_ S--i0A-C128 CONTR4L BUILDING ONE-LINE DIAGRAM & DETAILS APVD f�.�5 M � <br /> HANDNOL.E � <br /> PP LIGHTING CONTROL SYSTEM PQWER PACK Y CONTACTOR S-10A-C129 CONTR4L BUILDING IVREC FORMS � <br /> . MH MANHOLE �;� S-10A-C130 CONTROL BUILDING NREC F4RMS p,q�� �d (2a {�..�a" a <br /> - SB SWITCH BYPASS DEVICE N <br /> RELAY COiC. <br /> � ICS1--1 IL�UMINATION CONTROL STATION CR CR - CONTROL RELAY. TD-TTME DELAY RELAY� � <br /> � - SYMBOLS LEGEND — GENERAL os CEILING MOUNT�D OCCUPANCY SENSOR WITH POWER PACK = UV - UNDERVOLTAGE RELAY� M-MOTOR CONTACTOR GE NE RAL. N� T E � � <br /> 0 <br /> PASSIVE INF'RARE� TYPE UNL.ESS NOTED: gE VERL Y PARK o <br /> SYMBOL DESCRIPTION $ MOTOR-RATED SWITCH - SIZE OL. PER MOT4R REQUIREMENT 1, ELECTRICAL SYM64LS AND ABBREVIATIONS ON THIS DRAWING APPLY TO THE <br /> OS U = ULTRASONIC SUBSTATION C(3NTROL BUILOTNG ONL.Y. SU�3STATION t <br /> ..�. H EQUIPMENT EMERGENCY SHUTDOWN SWITCH ` <br /> _ GROUND. CONNECTION OS DT � DUAL TECHNOLOGY � � CON7ROL BUILDING � <br /> DT N <br /> a <br /> ELECTRICAI.. LEGEND �a . <br /> � ��� GROUN� R00 PC �HOTOELECTRIC CONTROI. C�ILIN� MOUNTED Q <br /> uM <br /> • i GROUND WELL p � - <br /> � �S OCCUPANCY SENSOR WALL MC3UNTE� <br /> dM <br /> - �-Q AIR TERMINAL PC PHOTOELECTRIC CONTROL WALL M�UNTED � y <br /> REV DRAWING „�, <br /> .. � � � mQ.�.. . <br /> . � . Q S-10A--Ci22 %� <br /> #. <br /> - am <br />