Laserfiche WebLink
PROJECT DESCRIPTION: <br /> HOUSE REMODELING <br /> OLEKSANDR NAUMETS <br /> 37'-6" 1924 MCDOUGALL AVE <br /> 0 0 0 0 EVERETT WA 98201-2459 <br /> Wood cafe LEGAL DESCRIPTION <br /> • EVERETT DIV K PLAT OF BLK 384 0-00 - 2012WA STATE ENERGY CODE COMPLIANCE: PROJECT ADDRESS: <br /> N1/2 LOT 20 &ALL LOT 21 <br /> ?FR TAM R402 1 1• PROJECT NAME: NAUMETS RESIDENCE REMODEL <br /> N PARCEL TAX I.D. # MAXIMUM VERTICAL GLAZING U-VALUE: 0.30 PROJECT ADDRESS: 1924 MCDOUGALL AVE <br /> 00437938402000 MAXIMUM OVERHEAD GLAZING U-VALUE: 0.50 EVERETT.WA 98201-2459 <br /> MAXIMUM DOOR GLAZING U-VALUE: 0.20 <br /> II II HEIGHT CALCULATIONS PROPOSED INSULATION: PROJECT SCOPE: HOUSE CONSTRUCTION OF SINGLE FAMILY <br /> 37'-6" CEILNGS WITH ATTICS: R-49 <br /> BENCH MARK VAULTED CEILINGS: R-38- <br /> Wood Fence - Wood Fence • Manhole RIM El EV. = 100' ABOVE GRADE WALLS; R-21 TAX 101 <br /> b BELOW GRADE INTERIOR WALLS: R-21 (R-15 RIGID) PARCELL 100437938402000 <br /> ' " BELOW GRADE EXTERIOR WALLS: R-10 <br /> B=98-11LEGAL DESCRIPTION: <br /> Asphalt Paved - FLOORS R_30• <br /> ;Lp'1 m - AreaII C=99-10 SLAB ON GRADE: R-10 <br /> _ 0=98,-10" <br /> 395'-7"s4=98'-11"AVERAGE(BASE ELEV.) ADDITIONAL REQUIREMENTS' <br /> v n II +78'ALLOWED INSULATION: <br /> 126'-11"=MAX HEIGHT EXT.WALL HEADERS R-10.SEE 13/A8.02 FOR PROJECT TEAM: <br /> DETAILS <br /> PIPING&DUCTING IN ARCHITECTS• OWNER- <br /> • LOT COVERAGE BY BUILDING UNCONDTONED SPACE R-8(WRAPPED) VIZCANDI ARCHITECTURE NAUMETS OLEKSANDR <br /> •• 1,1 0 / 601, 108TH AVE NE. 19TH FLOOR 1924 MCDOUGALL AVE. <br /> EXISTING SIZE 4500 <br /> BUILDING 1391 SF ALL DUCTS/BUILDING CAVITIES/AIR HANDLERS/FILTER BOXES USED BELLEWE WA 98004 EVERETT,WA 98201-2459 <br /> 11 BUILD. SF_ LOT SF=31% AS DUCTS SHALL BE SEALED.JOINTS AND SEALS TO COMPLY WITH <br /> SECTION M1601.3 OF 2012 IRC/SECTION 603.9 OF 20122 WE.DUCTS CONTACT:M,H,JAZZ LACKEY CONTACT: 5 OLEKSANOR <br /> SHALL BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33,USING MAX. PH:206-349-5606 PH:425-273-4990 <br /> IMPERVIOUS AREA DUCT LEAKAGE RATES SPECIFIED IN SEC 503.10.3 OF THE 2012 WSEC. EMAIL:vizeandi0ouUook.com EMAIL: <br /> u <br /> EXISTING: 1491 SF DUCT LEAKAGE TESTING TO BE CONDUCTED BY A QUALIFIED TECHNICIAN <br /> PROPOSED: 422 SF &DUCT LEAKAGE AFFIDAVIT TO BE POSTED NEXT TO ELEC.PANEL. <br /> e'-7" TOTAL: 1913 SF• PROVIDE A PROGRAMMABLE THERMOSTAT WHICH SHALL ALLOW FOR A - - <br /> Proposed Wood Steps - MINIMUM 5-2 PROGRAMMABLE SCHEDULE AND CAPABLE OF PROVIDING <br /> .I NORTH AT LEAST TWO PROGRAMMABLE SETBACK PERIODS PER DAY. <br /> II c d Wood P h SCALE: 3/32"=1' <br /> ADDITIONAL CREDIT.PER R406.2 WSEC 2012,PROVIDE 1.5 CREDITS FOR <br /> `. \ 12' 7 �'O n D MEDIUM DWEWNG HOUSE.PROVIDE GAS/PROPANE/OIL FIRED WATER. <br /> Wood Fence .' I _,I HEATER WITH MINIMUM E.F.OF 0.82.WATER HEATER SHALL HAVE <br /> (Divided by Prop Line) OI :'I SEPARATE FUEL SHUT OFF,NON COMPRESSIBLE R-10 PAD AND <br /> 1 I ;O •1, • —% TEMPERATURE SETTING SHOULD BE MAINTAINED AT 120'F. ZONING INFORMATION: <br /> 4 ' II AT LEAST 75%OF ALL INTERIOR LUMINARIES AND ALL EXTERIOR. <br /> $ 4 13 10 LUMINARIES SHALL BE HIGH EFFICIENCY PER WSEC 2012 SEC 404.1. <br /> HIGH EFFICIENCY LUMINARIES ARE DEFINED AS A LIGFITING FIXTURE THAT ZONING R-2 <br /> I) DOES NOT CONTAIN A MEDIUM SCREW BASE SOCKET(E24/E26)AND <br /> CONSTRUOCCUPANCTION: <br /> WHOSE LAMPS OR OTHER UGHT SOURCE HAVE A MIN.EFFICIENCY OF <br /> \ -60 LUMENS PER WATT FOR LAMPS OVER 40 WATTS BUILDING COVERAGE CALCULATIONS: <br /> -50 LUMENS PER WATT FOR LAMPS OVER 15 WATTS TO 40 WATTS TOTAL SITE AREA: <br /> 2'-0• 12'-0" - -40 LUMENS PER WATT FOR LAMPS 15 WATTS OR LESS. EASEMENT AREA <br /> PROVIDE MOTION SENSOR/PHOTO-DAYLIGHT CONTROLS FOR ALL ALLOWED STRUCTURAL COVERAGE: <br /> ALLOWED IMPERVIOUS COVERAGE: <br /> of o OUTDOOR LIGHTING. PRESENT STRUCTURAL COVERAGE: <br /> I I PRESENT IMPERVIOUS COVERAGE <br /> THE RESIDENTIAL ENERGY CODE COMPLIANCE CERTIFICATE SHALL BE PROPOSED STRUCTURAL COVERAGE: <br /> COMPLETED BY THE BUILDER REGISTER PROFESSIONAL AND SHALL BE PROPOSED IMPERVIOUS COVERAGE: <br /> 1 3 POSTED WITHIN 3'-0"OF THE&EC.PANEL <br /> ^I f II' SETBACK REQUIREMENTS <br /> D=98'-10" I B=98'-11' GENERAL PROVISIONS: FRONT: 1171 SFT <br /> •. r - • REAR: <br /> 1 VENTILATION REQUIREMENTS(PFR 2017 IRC)- SIDE: 631 OFT <br /> VII 7-4 -Ir•••• -FRAME HOUSE It 2.-6. - SOURCE SPECIFIC VENTILATION REQUIREMENTS 1802 SFT <br /> =o BATHROOM/LAUNDRY ROOM/POWDER ROOM FANS: 65 CFM EXISTING FIRST FLOOR AREA <br /> I WITH BASEMENT - KITCHEN EXHAUST FANS 100 SFM EXISTING GARAGE ARES <br /> �� I T ( •#1824 nl,'. EXHAUST FANS FLOW RATED 0.25 W.G.STATIC EXISTING SECOND FLOOR AREA <br /> A I PRESSURE TOTAL EXISTING BUILDING AREA <br /> 3 <br /> EXHAUST DUCTS SHALL PROPOSED FIRST FLOOR ADDITION: <br /> Roof Overhang -BE INSTALLED TO R-4 IN UNCONDITIONED SPACE TOTAL FIRST FLOOR: <br /> / -BE EQUIPPED A BACKORAFT DAMPER. PROPOSED TOTAL BUILDING AREA: R <br /> -TERMINATE OUTSIDE THE BUILDING <br /> -COMPLY WITH BELOW MAXIMUM HEIGHT ALLOWED(PITCH ROOF):126'-11" <br /> T 3 I FAN CFM MAX.FLEX DIA MAX FT. MAX.SMOOTH DIA MAX.FT NO CHANGE IN THE EXISTING HEIGHT OF THE BUILDING. <br /> v _ �v _ 50 4" 25' <br /> 50 5" 90' 5" 100' FLOOR/AREA RATIO(FAR): r <br /> o I 50 6" OVER 100' 6". OVER A 5 _ <br /> I 3 100' - SQUARE FOOTAGE IS MEASURED TO THE OUTSIDE FACE OF WALLS.STAIRS - e <br /> - 80 4" NOT ALLOWED 4" 20' ARE <br /> 80 5" 15' 5" 100' COUNTED ONCE IN CALCULATIONS.OPEN TO BELOW SPACES ARE NOT 6 E <br /> 0 <br /> ❑ I Li 800 5" NOT ALLOWED 5" OVER 100' ININCCALCULATIONS. <br /> W ... 100 6" 45' 6" OVER 100' <br /> .,✓ I 26 S( -,, 25'-a" 125 6' 15' 6" OVER 100' <br /> 125 6" 17' 7" OVER 100' <br /> J VICINITY MAP: <br /> i I Cov d W tl 99' 10" - 2.KITCHEN RANGE HOOD <br /> P h I ENSURE KITCHEN RANGE HOOD MEETS ALL THE CRITERIA OF SEC 111503.4 IRE <br /> / `/13 •10 2012.IF THE KITCHEN HOOD EXHAUST IS RATED AT MORE THAN 400 CFM,THEN <br /> / MAKE UP AIR MUST BE PROVIDED EQUAL TO THE AIR EXHAUSTED.THE REQUIRED <br /> __ o MAKEUP AIR SYSTEM MUST BE INTERLOCKED WITH THE HOOD SO WHEN THE MAKE <br /> 1 /Proposed Wood Step OP AIR SYSTEM AUTOMATICALLY TURNS ON WHEN THE HOOD IS TURNED ON. <br /> _ I` ' 0\ LEGEND: V SMOKE Al ARMS <br /> i _ T © = SEWER MANHOLE SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS Yu McOn�pYA CE <br /> 3'anI 1.IN EACH SLEEPING ROOM. I-S <br /> / 2.OUTSIDE EACH SEPARATE SLEEPING AREA N THE IMMEDIATE VICINITY OF THE <br /> I <br /> 4-9 �/10 —)—}--)—}-- =SEWER LINE BEDROOMS.' I-o 0 <br /> W -WATER LINE 3.ON EACH STORY OF THE DWELLING. W m <br /> I THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE o <br /> ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE RESIDENCE. _-c <br /> %Property Line— 3 WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER U Lao.� <br /> THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. IX z m o o. <br /> — <br /> 3 I Z w o'I N.' <br /> III- 4. WATER RESISTANT OWB SHALL BE USED ON WAILS AROUND SHOWER AND m-a 3 n u <br /> NON-AS.FINISH ALL WALLS ADJACENT TO SHOWER AND AWITH SMOOTH,37 6" NON-ABSORBENT MATERIAL UPTO 7'-0"HEIGHT ABOVE DRAIN. 6 w 4 m H o$, <br /> / a 3 5.CARBON MONOXIDE ALARM.PROVIDE A UL 2034 COMPLIANT CARBON MONOXIDE ALARM <br /> '+�U'T�rr <br /> fn N_�.. <br /> U' OUTSIDE MS INS EACH LLSEPARATE 8315 AND AREA IA INSTE VICINITY OF THE W.j 0 0 0 3 m <br /> BEDROOMS.INSTALL PER IRC R315 AND MANUFACTURERS INSTRUCTIONS. 0 <br /> / r 6.STAIRWAY ILLUMINATION:PROVIDE LIGHT SOURCES FOR ILLUMINATION OF NEW AND "'" <br /> EXISTING STAIRCASES IN THE IMMEDIATE VICINITY OF EACH LANDING OF THE STAIRWAY. <br /> C o e t e 3 W a Ik LIGHT SOURCES SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS <br /> �. NOT LESS THAN 1 FOOT-CANDLE 11 LUX)MEASURED AT THE CENTER OF TREADS AND <br /> LANDING) <br /> 7.WHOLE HOUSE VENTILATION SYSTEM:PROVIDE A WHOLE HOUSE VENTILATION SYSTEM CODES&SPECIFICATIONS: <br /> / THAT PROVIDES OUTDOOR AIR AT A CONTINUOUS RATE AS PRESCRIBED IN IRC TABLE <br /> M1 S07.3.3.1.THE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM SHALL BE PROVIDED <br /> 3 WITH CONTROLS THAT ENABLE MANUAL OVERRIDE. 1.2012 INTERNATIONAL RESIDENTIAL CODE. <br /> 2.2012 WASHINGTON STATE ENERGY CODE(WAC 51-11 WSEC) <br /> 3.2012 NATIONAL DESIGN SPECIFICATIONS(NDS)FOR WOOD w <br /> SHEET INDEX: CONSTRUCTION. o <br /> 4.2012 INTERNATIONAL BUILDING CODE. 0 <br /> Al TITLE SHEET.CODE COMPLIANCE INFO,SITE PLAN LU OLL <br /> A2 FLOOR PLAN-LEVEL 1 tr- Z <br /> Concrete Curb 3 A3 FLOOR PLAN-LEVEL 2,BASEMENT w w <br /> A4 ELEVATIONS-EAST,WEST,DETAILED WALL SECTION U U <br /> AS ELEVATION-NORTH.SOUTH Z <br /> A6 PLAN-FRONT,BACK PORCH.VIEW- 1,2 p¢.L Z <br /> "C <br /> E1.=100 _ <br /> m Ha <br /> --4,-(—T—(—(—(--( (—(—(--(--(—(—(—(--(--( <br /> I� MCDOUGAL 3 AVE. .5 wMz <br /> ( V (--(—(—(—( (—(—(—(—(—(—(—(—(—(�—(—(—(—(—(—(—(—(—(—(—(—(—(—(—(- H 83 =OJ <br /> L. wa <br /> Oma,rWow <br /> Al 3 <br />