6515 MORGAN RD SPRINT ANTENNA 2019-02-12
>
Address Records
>
MORGAN RD
>
6515
>
SPRINT ANTENNA
>
6515 MORGAN RD SPRINT ANTENNA 2019-02-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2019 11:27:51 AM
Creation date
2/12/2019 11:27:44 AM
Metadata
Fields
Template:
Address Document
Street Name
MORGAN RD
Street Number
6515
Tenant Name
SPRINT ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the base of the monopole and the power density is 0.001761 mW/cm2 with an <br /> assumed power level of 2,000 watts. This is 0.3303% of the MPE limit for the <br /> general population/uncontrolled exposure of 0.533 mW/cm2 as referenced in <br /> Table I OET Bulletin 65 Appendix A for the lowest frequency range. <br /> OTHER CARRIERS <br /> The following are examples of wireless carriers providing service in Snohomish <br /> County: <br /> ESMR 851-866 Mhz Nextel <br /> Cellular 869-894 Mhz AT&T, Verizon <br /> PCS > 1800 Mhz Sprint, T-Mobile, AT&T <br /> In order to develop a "worst case prediction", it is assumed that all other wireless <br /> facilities on the tower have maximum effective radiated power (ERP) levels of <br /> and 2,000 watts for the wireless carrier panel antennas. <br /> Wireless facility antennas are highly directional and project the majority of the RF <br /> energy horizontally. Attached as an exhibit are the MPE (Maximum Permissible <br /> Exposure) calculations using the referenced power density formula. These <br /> calculations assume that the vertical patterns of the antennas suppress the ERP <br /> by 20 dB towards the antenna base. The calculations show that the maximum <br /> total MPE at ground level (6' above AGL) at the base of the monopole is <br /> 0.002751 mW/cm2. This is 0.5891% of the MPE limit for the general <br /> population/uncontrolled exposure of 0.467 mW/cm2 for the lowest frequency <br /> (700/1500) as referenced in Table I OET Bulletin 65 Appendix A. <br /> COLOCATED FACILITIES TOTAL MPE <br /> The combined MPE for the Sprint antennas and the existing carriers using "worst <br /> case" calculations is: 0.001761 mW/cm2 + 0.002751 mW/cm2 = 0.004512 <br /> mW/cm2 Total MPE. <br /> ENVIRONMENTAL EVALUATION <br /> Routine environmental evaluation is required if the PCS broadband facility is less <br /> than 10 m (32.81 feet) AGL and has a total power of all channels in any given <br /> I/3 `t <br />