• GROUNDING NOTES <br /> 1. AU.DETAILS ARE SHOWN IN GENERAL TERMS.ACTUAL GROUNDING INSTALLATION AND <br /> CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDR10N5. <br /> 2. GROUND ALL ANTENNA BASES,FRAMES,CABLE RUNS,AND OTHER METAWC COMPONENTS <br /> USING/2 GROUND WIRES AND CONNECT TO SURFACE MOUNTED GROUND BUS BARS A5 <br /> SHOWN.FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING <br /> REQUIREMENTS.GROUND COAX SHIELD AT BOTH ENDS USING MANUFACTURERS PRACTICES. INSTALL MOUNTING FIFE(TYP) � <br /> AU.UNDERGROUND WATER PIPES,METAL CONDUITS AND GROUNDS THAT ARE A PART 0E11115Imo <br /> SYSTEM SHALL BE BONDED TOGETHER. SYMBOL LEGEND <br /> 3. ALL GROUND CONNECTIONSSHALL BE/2 AWG U.N.O.ALL WIRES SHALL BE COPPER THHNMIVIN. EXOTHERMIC CONNECTION <br /> i_i\ 1 <br /> INSTALL ANTENNA(IYF) /� <br /> AU.GROUND WIRE SHALL BE SOLID TIN COATED OR STRANDED GREEN INSULATED WIRE. - `� m MECHANICAL CONNECTION `/ , <br /> 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE,5 OHMS MAXIMUM. PROVIDEhg tie <br /> summon-GROTNNDING RODS AS REQUIRED TO ACHIEVE SPECIFIED OHMS READING. NS '�'i <br /> GROUNDING AND OTHER OPTIONAL TESTING WILL BE WITNESSED BY THE SPRINT INSTALL RPM(TIP) I— — <br /> REPRESENTATIVE <br /> 5. NOTIFY ARGf1RECT1BiGINEERIFTHERE ARE ANY DIFFICULTIE5INSTALLING GROUNDING SYSTEM i �- a <br /> DUE TO SITE SOIL CONDITIONS. JUMPER CABLES(TIP) -��•• C g <br /> 6. BARE GROUNDING CONDUCTOR SHALL BE HARD DRAWN TINNED COPPER SIZES AS NOTED ON �v I 4-J <br /> PIM. FIBER 4 DC CABLES(TYP) • <br /> L' <br /> 7. ALL HORIZONTALLY RUN GROUNDING CONDUCTORS SHALL BE INSTALLED MINIMUM 30'BELOW a 1 <br /> GRADE/FROST-LINE IN ROST-LTRENCH,U.N.O.,AND BACK FILL SHALL BE COMPACTED AS REQUIRED BY 'o <br /> ARCHITECT. <br /> 8. ALL GROIN)CONDUCTORS SHALL BE RUN AS STRAIGHT AND SHORT AS POSSIBLE,WHH A <br /> !MA'AM IT EBBING RADIUS NOT LESS THAN 90 DEGREES. BREAK OUT CYUNDERS(TIP) 5 a^, <br /> 9. ALL SUPPORT STRUCTURES,CABLE CHANNEL WAYS OR WIRE GUIDES SHALL BE BONDED TO ` ` <br /> GROUND SYSTEM AT A PONT NEAREST THE MAIN GROUNDING BUS TMGB'(OR DIRECTLY TO <br /> GROUND-RING). 1 —1 <br /> 10. ACCEPTABLE COW:MONS FOR GROUNDING SYSTEM SHALL BE: POWER1,06 ri RACK RECTIFIER i z 6a.BURTDY,HYD UL USTED CONNECTORS FOR INDOOR USE ORA5 APPROVED BYSPRINT PROCT MANoN 4.CADWID,EXOTHERMIC WENDS(WELDED CONNECTIONS). BATTERY avc�HOLETINNED COPPER COMPRESSION(LONG BARREL)FITTINGS(BUS BAR I I BAR5(TYP) III NDkE 'Jill <br /> II. ALL CRIMPED LOAN ECTIOS SHALL HAVE EMBOSSED MANUFACTURERS DIEMARK VISIBLE AT TUB / Za' OM <br /> CRIMP(RESULTING FROM USE OF PROPER CRIMPING DEVICES). UPPER GROUND BAR O <br /> 12. PRDRTO ANY LUGBUSBARCONNECTIONS,THE BUS BAR SHALL BE CLEANED BY USE OF U) ei <br /> "a ni <br /> WENCH-MTV OR PLAIN STEEL WOOL AS TO REMOVE ALL SURFACE OXIDATION AND <br /> U a �I- i <br /> CONTAMINANTS.ACOATING OF NO-0X-ID'SHALL BE APPLIED TO THE CONNECTION SURFACES. L1.1o l <br /> 13. ALL CONNECTION HARDWARE SHALL BE TYPE 316 55(NOT ATTRACTED TO MAGNETS). a. ! i <br /> 14. THE GROUND RING SHALL BE INSTALLED 24'MINIMUM BEYOND ANY BUILDING DRIP UNE. S. , Ibis <br /> 15. ELECTRICAL SERVILE EQUIPMENT GROUNDING SHALL COMPLY WITH NEC,ARTICLE 250-82 AND L EQUIPMENT GROUND <br /> SHALL BOD ALL EXISTING MID NEW GROUNDING ELECTRODES.NEW GROUNDING ELECTRODE <br /> SHALL INCWDE BUT NOT UNITED TO GROUND RODS,GROUND RING IF SERVICE IS WITHIN THE <br /> RADIO EQUIPMENT LOCATION,BUILDING STEEL IF APPLICABLE,COLD WATER CONNECTIONS MUST ��.-° <br /> 8E MADE ON THE Stt15LDE Of MAIN SHUT-OFF VALVE l ' <br /> O GROUNDING DIAGRAM �i� <br /> 02 AWG PROM EQUIPMENT NTS E'41avu t <br /> TO BE GROUNDED <br /> GROUND BAR X I I I II I EVERGREEN <br /> 11111111 <br /> 111 11 1 WAY <br /> nnnn t1n n <br /> 0 NHHH EH H 0 <br /> SE54XCI02 <br /> 6515 MORGAN ROM <br /> 1 DUAL CADWEDS,TO 5E 1 EVERETT,WA 98203 <br /> I USED WO 2 AWG KW <br /> TO GROUND RING I SILICON SEAL <br /> P .PI AT TOP ISSUE STATUS <br /> I'OVC SEALTNE A DATE DESCRIPTION <br /> OHI 1/17 (2)90% <br /> NOTE: 08/22/17 CD 100% <br /> I. CONTRACTOR TO UTILIZE KOPRSHIED(TRANS 4 BETTS)ON <br /> ALL WG CONNECTIONS OR APPROVED EQUAL <br /> 2. ALL LUGS TO BE DUAL HOIE LONG BARREL AND CRIMPED <br /> TWICE WIDI MFRS RECOMMENDED TOOL <br /> DRAWN BY: 5.DAVE <br /> �„� GROUNDING BAR CONNECTION DETAIL Nis APPROVEDY.9 .DCARLO <br /> M <br /> cCOMB <br /> DATE: 08/22/17 <br /> SHEETTR1E: <br /> GROUNDING DETAILS <br /> (a, --...4--...„ SHEET NUMBER <br /> E <br />