1927 W MUKILTEO BLVD CINGULAR WIRELESS ANTENNA 2019-02-20
>
Address Records
>
W MUKILTEO BLVD
>
1927
>
CINGULAR WIRELESS ANTENNA
>
1927 W MUKILTEO BLVD CINGULAR WIRELESS ANTENNA 2019-02-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2019 12:45:18 PM
Creation date
2/12/2019 12:01:14 PM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
1927
Tenant Name
CINGULAR WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br /> • <br /> GROUNDING KEYED NOTES <br /> OEXISTING EXTERNAL GROUND RING.(V.I.F.) <br /> =PLANS PREPARED BY: <br /> orn—• EF NFLIST00NE <br /> O PROPOSED LUG GROUND CONNECTION TO EQUIPMENT.SEE DETAIL 9/E-1.1 16928 WOODINVILLE-REDMOND RD NE,SUITE 210 <br /> WOODINVILLE,WA 98072 <br /> O7PROPOSED CADWELD GROUND CONNECTION TO STEEL. PHONE:STONE-1732 <br /> SEE DETAIL 4/E-1.1 WWW.CORNERTONE{NGR.COM <br /> (E)RETAINING WALL W/WOOD =PROJECT INFO: <br /> SCREEN WALL ABOVE <br /> (E)ICE BRIDGE(TYP) O PROPOSED#2 SOLID TINNED COPPER GROUND LEAD FROM STEEL WA6451 <br /> (E)CONDUIT(TYP) TO GROUND RING. <br /> 10 PROPOSED#2 SOLID TINNED COPPER GROUND LEAD FROM EQUIPMENT EDGEWATER <br /> (E)FRAME MOUNTED EQUIPMENT TO GROUND RING. <br /> O <br /> REPLACEMENT DIPLEXER(TYP OF 2) 1927 W ETTWA 9 BLVD <br /> VERETT,WA 98203 <br /> SNOHOMISH COUNTY <br /> /- <br /> / _IIINIQ� --- ISSUED FOR: <br /> / s-- <br /> __ _ <br /> i - �� _ — ® c» CONSTRUCTION <br /> =___ <br /> / _ ___ _ [REV:_DATE: ISSUED <br /> FOR: BY:_ <br /> / / I / I (E) --'=-,=-7.=,-==.72=::.-.=.E.=====- _ sem <br /> / ,/ II I TE21 I/11 <br /> GROUNDING NOTES <br /> /I 11 Ii CABINET \\ <br /> 1/1 <br /> I Iii 1 ,i --- 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS.ACTUAL INSTALLATION AND <br /> i''..., <br /> \ i 11---f __ _---_ �uw!� CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. <br /> / I o 0 0, I 4 12-04-17 FINAL JRF <br /> • <br /> L_____j ==_ n 't 2. GROUND ALL ANTENNA BASES,FRAMES,CABLE RUNS,AND OTHER METALLIC <br /> / • I' / COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED <br /> / �\ (E) (E) �\ // 11-22-17 PRELIMINARY DMO <br /> BUS BARS.FOLLOW ANTENNA AND BTS MANUFACTURER'S PRACTICES FOR <br /> / • TE40 TE43 ♦ / GROUNDING REQUIREMENTS.GROUND COAX SHIELD AT BOTH ENDS AND EXIT <br /> / CABINET CABINET 90'1111 <br /> (E) II -DRAWN BY:=CHK.: APV.: <br /> / \ �� / FROM TOWER OR POLE USING MFR'S PRACTICES. r// \{ ' - _ ��� CABINET UMTS I I i % L DMO I MWO I MWO <br /> _ _ I \ 3. ALL GROUND CONNECTIONS SHALL BE CADWELD.ALL WIRES SHALL BE <br /> / I I //� /i'� %/G \%/ 00 ••EH <br /> IC 1 \ // COPPER THHN/THWN.ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE CURRENT ISSUE DATE: <br /> / // / agi I,I I \I /// ABOVE GROUND. 12-04-17 <br /> t __ <br /> _,. _IIIII�_��_n J<rL j J o a — —��——-_ 1 "/ 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE.GROUNDING AND _LICENSURE: <br /> -�L,a_` `_�T���_ -E -Ste '' ROTHER EPRESENTATIVE. TESTING WILL BE WITNESSED BY AT&T WIRELESS,LLC. <br /> • II ,,TIT7 SLEY h <br /> REPLACEMENTX!RRH, XERS(TYP OF 8) 5. REFER TO DIVISION 16 GENERAL ELECTRIC;GENERAL ELECTRICAL PROVISION J- of <br /> © O AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. �4e <br /> e • <br /> PROPOSED FLEX!RRH, IP <br /> ' Y G <br /> O • <br /> BELOW(TYP OF 2) 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING ` <br /> PROPOSED WCS RRH, SYSTEM,AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED AT&T <br /> ABOVE(TYP OF 2) WIRELESS,LLC.REPRESENTATIVE,PRIOR TO INSTALLATION OF GROUNDING ,ff¢k 7 <br /> SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING <br /> EXPANDED H-FRAME (E)BUILDING 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES JURISDICTIONAL APPROVAL: <br /> INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. <br /> ,u <br /> PROPRIETARY INFORMATION: <br /> I /// DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> AU.DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORS AND OMISSIONS.AU.PREVIOUS ISSUES OF THIS <br /> DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> .. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br /> LEGEND IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE <br /> OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS <br /> STRICTLY PROHIBITED. <br /> SYMBOL DESCRIPTION DRAWING TITLE: <br /> NOTE: 6 GROUND INSPECTION WELL SCHEMATIC GROUNDING PLAN <br /> ALL GROUNDING WIRE RUNS AND la <br /> CONNECTIONS,BOTH ABOVE AND COPPER GROUND ROD ,DRAWING NUMBER: <br /> BELOW GRADE,SHALL BE LOCATED ® COMPRESSION LUG <br /> `� <br /> INSIDE OF THE LEASE AREA LINE. --1 <br /> PLAN NORTH A CADWELD CONNECTION -�--`---EY—-I9- <br /> C_1 0 <br /> SCHEMATIC GROUNDING PLAN EQUIPMENT ® SIDE SPLICE CADWELD L <br /> 22x34 SCALE:3/4'=1'-0" 111x17 SCALE:3/8"='T-0" -- <br /> ‘..........kw. FIELD VERIFY&TIE INTO EXISTING GROUNDING SYSTEM CEI JOB NUMBER: LTE 3C 4C 17-09094 <br />