My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3211 NASSAU ST 2019-02-12
>
Address Records
>
NASSAU ST
>
3211
>
3211 NASSAU ST 2019-02-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2019 1:09:46 PM
Creation date
2/12/2019 1:09:39 PM
Metadata
Fields
Template:
Address Document
Street Name
NASSAU ST
Street Number
3211
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENGINEERING <br /> PUBLIC SERVICES DEPARTMENT <br /> July 21, 2017 <br /> Ben Ryan <br /> Ben@brothersconstractorsnorthwest.com <br /> RE: Owner: Brian Churchill <br /> Job Address: 3211 Nassau St. <br /> Plan Check Number: B1707-019 <br /> Dear Mr. Ryan, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. These comments address building issues only. Additional <br /> revisions or additions may be required by other departments (such as Public Works, Planning, or <br /> Fire). All references refer to the 2015 International Building Code (IBC), the 2015 International <br /> Existing Building Code (IEBC), the 2015 International Property Maintenance Code (IPMC), the 2015 <br /> International Fire Code (IFC), the 2015 International Mechanical Code (IMC), and the 2015 <br /> International Energy Conservation (IECC), as amended by the State of Washington (WSEC) and <br /> adopted by the City of Everett. The current IBC referenced standard for accessible design is the <br /> 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA, FHA, and <br /> HUD regulations and standards, including the Fair Housing Accessibility Guidelines may be more <br /> restrictive. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of construction documents <br /> reflecting the corrections requested. <br /> Structural <br /> 1. Provide lateral calculations for the stair structure, especially when evaluating connections, <br /> members, and footings shown in Sections 1 and 2. <br /> 2. Please provide gravity calculations for the new stair design that meets the loads and <br /> deflection requirements indicated in the structural notes. See IBC 2015 Tables 1607.1 and <br /> Table 1604.3 for strength and deflection requirements, respectively. <br /> 3. Please provide calculations and connection details for handrails and guardrails meeting the <br /> loading requirements per IBC 2015 Section 1607.8. <br /> 4. If A35 clips are used to support stringer members, please provide calculations checking the <br /> strength of the connections to the supporting members. <br /> D.•e1of2 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257-8857 <br />
The URL can be used to link to this page
Your browser does not support the video tag.