.c BUILDING PLANNING <br /> WALL-\ <br /> 15 IN. WALL \ / I <br /> jr <br /> 1 0 30 IN. <br /> WALL` _, t 1. / i_ <br /> s <br /> CLEARANCE <br /> MIN. I <br /> iii <br /> 21 IN. <br /> CLEA <br /> 21 IN. <br /> CLEARANCE 24 IN.CLEARANCE IN <br /> FRONT OF OPENING <br /> SHOWER <br /> WATER CLOSET <br /> OR BIDET <br /> WALL <br /> WALL 15 IN.—� <br /> 15IN.1 ' 1 <br /> 211111111111■- <br /> - III <br /> - <br /> ` <br /> r <br /> CE 21 IN. <br /> CLEARANCE WALL <br /> IIIIII <br /> WATER CLOSETS WALL <br /> For SI: 1 inch=25.4 mm. <br /> FIGURE R307.1 <br /> MINIMUM FIXTURE CLEARANCES <br /> R308.3 Human impact loads. Individual glazed areas, R308.3.1 Impact test. Where required by other sections <br /> including glass mirrors in hazardous locations such as those of the code, glazing shall be tested in accordance with <br /> indicated as defined in Section R308.4, shall pass the test CPSC 16 CFR 1201. Glazing shall comply with the test <br /> requirements of Section R308.3.1. criteria for Category II unless otherwise indicated in Table <br /> Exceptions: R308.3.1(1). <br /> 1. Louvered windows and jalousies shall comply with Exception: Glazing not in doors or enclosures for hot <br /> Section R308.2. tubs, whirlpools, saunas, steam rooms, bathtubs and <br /> showers shall be permitted to be tested in accordance <br /> 2. Mirrors and other glass panels mounted or hung on awith ANSI Z97.1.Glazing shall comply with the test cri- <br /> surface that provides a continuous backing support. teria for Class A unless indicated in Table R308.3.1(2). <br /> 3. Glass unit masonry complying with Section R607. <br /> 58 2015 INTERNATIONAL RESIDENTIAL CODES <br />