My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1110 RAINIER AVE B DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
>
Address Records
>
RAINIER AVE
>
1110
>
DOMESTIC VIOLENCE SERVICES OF SNO CO
>
1110 RAINIER AVE B DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2019 10:30:42 AM
Creation date
2/13/2019 10:00:42 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
1110
Unit
B
Tenant Name
DOMESTIC VIOLENCE SERVICES OF SNO CO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
qRCARCMITECTS.COM 110� F P�RE5IREET FLOOF J SEA7TLEV.'A58t2^ 2�5 72? 7J22 P 205 3.: 9J77 P <br />• • <br />Response: Please refer to Building Code Data on sheet T1.0. All children ages 0-17 and their <br />mothers will be occupying this building. <br />a. NO, this will not be a childcare center. <br />b. YES, parents (mothers) will be accompa�ying the youth at all times. <br />a�� c. NO daycare services will be provided. <br />� d. NO food and drink will be provided. (Families may bring snacks but there will <br />be no food service or preparetion in this building. <br />2 If ihe bwlding use includes daycare, ihen sprinklers may be required, per IBC section 903 2 3, once <br />revised occupancy calculations are submitted for educational use, at 35 occupants per net sf, per <br />the definition of floor area, net, in IBC chapter 2, and IBC table 10004 1 2 <br />Response: Building use does not include daycare. <br />�3 Please mdicate the location and content oi the posted occupancy signs on the dra�vings for rooms <br />w�th assembly occupancy, per IBC table 1004.1.1 <br />Egress <br />Response: Please refer to floor plan for location and content of occupancy sig�s. <br />All assembly areas (mterior and designated exterror assembly areas), should have lhe following <br />indicated on lhe drewings. <br />a Emergency lighting should be shown on the reflected ceiling pian inside the building, per IBC <br />sections 1006 1 and 1006 3 <br />�� Response: Emergency power for illumination will be provided at both exit doors and at <br />exterior exit discharge. Please refer to the reflected ceiling plan for locations of <br />emergency lighting. There are no interior corridors and aisles in the building that require <br />emergency lighting. <br />b Where changes of elevation of less than 12 inches exist in the means of egress, sloped <br />surfaces should be shown on the drawings, per IBC section 1003 5 <br />. -.;y, Response: There are no changes of eievation within the building. The east exit door will <br />i����t�j be flush with the exterior tinish grade, providing one accessible means of egress' for the <br />�: building. The west exit door has an elevation change of 9 inches from the tinish (loor to <br />� � the existing exterior pavement. A landing will be provided that connects to adjacent , <br />asphalt paving, so flush with finish grade. <br />. . , ��, <br />�� 'Per Section 1007 (Accessible Means of Egress) Ezception 1: Accessible means of egress �� •. <br />are not required in alterations to existing buildings. (We can however provide onc) • <br />�� <br />� <br />� ic Tactde exd signs should be shown on the drawings adjacent ro each door to lhe exit <br />discharge, per IBC sect�on 1011 3 <br />Response: Please reter to 21A2.1 �nd 31A2.1 tor locations oi tactile exit signs. <br />�'� d I( locks and latches are provided on doors or gates in assembly areas, signage per IBC <br />1 sect�on 1008 1 9 3 should be shown on lhe drawings for each of these areas <br />� Response: Both exit doors will be provided with signage that reads "THIS DOOR TO <br />REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" and will be posted adjacent to the <br />� door, egress sitle,'Please refer to 2/A2.1 (or location. <br />i� ��S <br />��if` � Ao'..-.__ �_..�. <br />_ i <br />����� �� � <br />� s` ' Zl Y <br />�, <br />, <br />'-. <br />
The URL can be used to link to this page
Your browser does not support the video tag.