Laserfiche WebLink
I <br /> FRAME TYP S DOOR SCH DUL NOTES OO <br /> PER SCHEDULE 1. ALL DOOR HARDWARE SHALL BE FULLY ACCESSIBLE PER THE PROVISIONS OF ANSI A117,1 SECTION 404/T1.2, <br /> D � �C� �U� <br /> 2. AT THE MAIN EXTERIOR DOOR, LOCKS & LATCHES SHALL BE PERMITTED IF THE LOCKING DEVICE IS READILY DISTINGUISHABLE <br /> AND A READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: "THIS OPENINGS FRAMES DCTAILS - <br /> DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED . THE SIGN SHALL BE IN LEfTERS 1 HIGH ON A CONTRASTING � � <br /> BACKGROUND & MEEf REQUIREMENTS OF IBC 1008.1.9.3 LOCKS & LATCHES. <br /> 3. EXTERIOR DOORS TO BE STEEL, 20 GAUGE, FULL FLUSH WITH FIBROUS HONEYCOMB CORE, BAKED ON PRIMER. EXTERIOR N O. TY P E W X H T H K M AT� G L I N S U L H D W F N TY P E M AT L I ( N H D J A M B S L L REMARKS <br /> � � DOOR FRAMES TO BE STEEL, 18 GAUGE WITH 2" FACES AND 5/8" STOPS FORMED INTERNAL CORNERS MITERED, WELDED AND <br /> o GROUND SMOOTH, BAKED ON PRIMER, U.N.O.. 100 FG 3'-0" X 7'-0" 1 3 4" ALUM TIG PER <br /> w 4. ALL STOREFRONT ENTRY DOORS SHALL BE CERTIFIED & LABELED WITH ITS MAX. U-FACTOR & SOLAR HEAT GAIN COEFFICIENT � COVERSHEET A CLEAR ANOD. 1 ALUM CLEAR ANOD. 10/A6.2 9/A6.2 8/A6.2 <br /> � BY AN INDEPENDENT AGENCY LICENSED BY THE NFRC, IN COMPLIANCE WITH THE VALUES LISTED ON SHEET CS. 101 F 3'-0" X 7'-0" 1 3/4" HM - COVERSHEEf C PAINT 1 HM PAINT 7/A6.2 6/A6.2 5/A6.2 <br /> cn 5. DOORS OPENING INTO SEMI-HEATED SPACE, UNCONDITIONED SPACE OR TO THE EXTERIOR TO COMPLY WITH VALUES LISTED ON 102-103 FG 3'-0'� X 7'-0" 1 3 4" ALUM TIG PER <br /> � SHEET CS. � COVERSHEET A CLEAR ANOD. 1 ALUM CLEAR ANOD. 10/A6.2 9/A6.2 8/A6.2 <br /> � � 104 F 3'-0" X 7'-0" 1 3/4" HM - COVERSHEET C PAINT 1 HM PAINT 7/A6.2 6/A6.2 5/A6.2 '�� <br /> 105 FG 3'-0" X 7'-0" 1 3/4" ALUM TIG COVERSHEET A CLEAR ANOD. 1 ALUM CLEAR ANOD. 10/A6.2 9/A6.2 8/A6.2 <br /> � 106-108 F 3'-0" X 7'-0" 1 3/4" HM - COVERSHEEf C PAINT 1 HM PAINT 7/A6.2 6/A6.2 5/A6.2 � �' C �'T I # @ C � S <br /> 109 S 12'-0'� X 14'-0" - - - COVERSHEET B PRE-FINISHED - - - 4/A6.2 3/A6.2 2/A6.2 <br /> DOOR TYPES DOOFi HARDWARE NOTES 110-113 S 9'-0'� X 10'-0" - - - COVERSHEET B PRE-FINISHED - - - 4/A6.2 3/A6.2 1/A6.2 2505 Third Avenue <br /> PER DOOR SCHEDULE TYPE A: EXTERIOR PUSH PULL BARS, CLOSER, DEAD BOLT WITH ADA 114 F 3'-0'� X 7'-0" 1 3/4'� HM - PER Suite 324 <br /> / COVERSHEEf C PAINT 1 HM PAINT 7/A6.2 6/A6.2 5/A6.2 Seattle, WA 98�21 <br /> LEVER AND BUILDING SIGNAGE 'THIS DOOR TO REMAIN OP�N 115-119 S 9'-0" X 10'-0" - - - COVERSHEET B PRE-FINISHED - - - 4/A6.2 3/A6.2 1/A6,2 <br /> DURING BUSINESS HOURS', WEATHER STRIPPING, & DOOR <br /> PER DOOR SCHEDULE PER DOOR SCHEDULE SWEEP 120 F 3'-0" X 7'-0" 1 3/4° HM - COVERSHEEf C PAINT 1 HM PAINT 7/A6,2 6/A6.2 5/A6.2 206.720.7001 phone <br /> � 121-122 S 12'-0'� X 14'-0" - - - _ _ _ 206.720.2949 fax <br /> �'-� TYPE B: SECTIONAL OVERHEAD DOOR HARDWARE, LATCH ABOVE TRACK COVERSHEET B PRE-FINISHED 4/A6,2 3/A6.2 2/A6.2 <br /> � GUARD 123 F 3'-0" X 7'-0" 1 3/4" HM - COVERSHEET C PAINT � HM PAINT 7/A6.2 6/A6.2 5/A6.2 www.craftarchitects.com <br /> w w o <br /> > > � � TYPE C: STOREROOM LOCKSEi, CLOSER, WEATHER STRIPING, DOOR �24-�28 S 9'-0" X 10'-0" - - - COVERSHEET B PRE-FINISHED - - - 4/A6.2 3/A6.2 1/A6.2 <br /> � � cn SWEEP, LATCH GUARD & DRIP 129 F 3'-0" X 7'-0" 1 3/4'� HM - COVERSHEET C PAINT 1 HM PAINT 7/A6.2 6/A6.2 5/A6.2 <br /> _ _ � <br /> � � 0 130-133 S 9'-0" X 10'-0" - - - COVERSHEET B PRE-FINISHED - - - 4/A6.2 3/A6.2 1/A6.2 <br /> o p , , � 134 S 12'-0" X 14'-0" - - - COVEqSHEEf B PRE-FINISHED - - - 4/A6.2 3/A6.2 2/A6.2 <br /> 0 o w 135-137 F 3'-0" X 7'-0" 1 3/4" HM - COVERSHEET C PAINT 1 HM PAINT 7/A6,2 6/A6.2 5/A6.2 <br /> � <br /> � � .. TIG 200 F 3'-0" X 7'-0" 1 3/4'� HM - COVERSHEET C PAINT � NM PAINT 7/A6.2 6/A6.2 5/A6.2 <br /> � °- � 201 F 3'-0" X 7'-On 1 3/4" HM - COVERSHEET � PAINT 1 HM PAINT 7/A6.2 6/A6.2 5/A6.2 <br /> � � <br /> F (FLUSH) FG (FULL GL4SS) S <br /> SECTIONAL <br /> � <br /> � � <br /> � � <br /> � � <br /> . s � <br /> � v, � <br /> U - � � <br /> a � <br /> J � <br /> � <br /> U - u, � <br /> �- � cn w <br /> � � °C <br /> w <br /> > <br /> . � � <br /> CONSULTANT <br /> 7os� <br /> <RE6ISTERE� <br /> ARCHITECT <br /> ��€ HfNG ON <br /> Submittals/Revisions: <br /> FOR PERMIT 05/04/16 <br /> -CEILING PER GA FILE NUMBER 4503 GUARDRAIL -CEILING PER GA FILE NUMBER 4503 <br /> -WALL PER GA FILE NUMBER 1072 -WALL PER GA FILE NUMBER 1072 <br /> COMPENSATION CHANNEL � ROOF DECK � FIRE-RATED 3/4" PLYWOOD DECKING 0/ 6" <br /> 1/2 MIN. GAP � 16 GA. MTL. STUDS � 16" O.C. MAX COMPENSATION CHANNEL � ROOF DECK � <br /> DEFLECTION (L/240) <br /> FIRE-RATED 3/4" PLYWOOD DECKING 0/ 6" 16 <br /> GA. MTL. STUDS � 16" O.C. MAX DEFLECTION 1/2 MIN. GAP <br /> (L/240) PAINTED 5/8" GWB, OVER 8" x 1-5/8", 18 ' <br /> GA. MTL STUDS � 24" O.C. MAX <br /> PAINTED 5/8" GWB, OVER 8" x 1-5/8", 18 GA. DEFLECTION (L/240) TO MEET SSMA <br /> � MTL, STUDS C� 24" O,C, MAX DEFLECTION • . . ..... ..... . .. . . ,..; , . .....,, o `r INTERIOR NON-STRUCTURAL COMPOSITE <br /> � (L/240) TO MEET SSMA INTERIOR , , , .. ; : . .: � <br /> . _ . _ TABLE <br /> � <br /> NON-STRUCTURAL COMPOSITE TABLE PAINTED 5/8" Tl'PE k' GWB CEILING, +� <br /> .. , - <br /> � z <br /> ` MAINTAIN 1 HR. FIRE RATING AT PUMP RM. : <br /> � WAREHOUSE � PAINTED 5/8" GWB, OVER 6� MT�. Sheet Title: DOOR SCHEDULE <br /> � <br /> '� PAI " " ' � ELEC ' FIRE PUMP S1 U240�BRAC D �MAX_�FAFFTIOE ELEC WAREHOUSE � <br /> z NTED 5/8 TYPE X' GWB CEILING, <br /> o ( / ) PR <br /> � MAINTAIN 1 HR. FIRE RATING AT PUMP STEEL STUD MANUFACTURERS <br /> � ROOM ASSOCIATIONS (SSMA) <br /> � MTL STUD RUNNER AT�ACHED TO CONC. MTL STUD RUNNER ATTACHED TO CONC. SLAB Date: 05 f 04/16 <br /> a : <br /> � FIRE PUMP : MTL STUD RUNNER ATTACHED TO TOP OF TILT UP SLAB W/ 5/32" DIA. LOW-VELOCITY W/ 5/32" DIA. LOW-VELOCITY POWER-DRIVEN <br /> ? CONCREIE PANEL W/ 5/32" DIA. LOW-VELOCITY POWER-DRIVEN FASTENER W/ 1 1/4' FASTENER W/ 1 1/4" PENETRATION MIN. PER Design: <br /> POWER-DRIVEN FASTENER W/ 1 1/4" PENEfRATION MIN. PER STUD STUD MANUFACTURER'S RECOMMENDATIONS. <br /> � PENETRATION MIN. PER STUD MANUFACTURER'S MANUFACTURER'S RECOMMENDATIONS. Drawn: <br /> � RECOMMENDATIONS W/ FIRESAFING. <br /> � <br /> 0 <br /> Project No: 15-198 <br /> 0 <br /> 0 <br /> a 1 HR RATED PARTITIC�N WALL/CEiLING PARTITIC�N FULL HEIGHT PARTITICJN Approved: <br /> �' 3 2 1 <br /> Building No: BUIIDING A <br /> � <br /> 0 <br /> 0 <br /> � <br /> Sheet No: <br /> . <br /> � <br /> 0 <br /> � <br /> 0 <br /> COPYRIGHT CRAFT ARCHITECTS 2016 <br />