a TPO ROOF 1 1/2" <br /> CONCRETE WALL PANEL <br /> TPO ROOF, EXTEND DOWN FULL <br /> HEIGHT OF PLYWOOD, FASTEN PER � � � <br /> n MANUFACTURER'S RECOMMENDATIONS, � a � CONC TILT-UP WALL <br /> ( I o MINIMUM 12" O.C. Q a _ CHANGE IN PAINT COLOR� a a a PANEL <br /> EXTENDABLE SAFETY i i CURB W/ INTEGRAL M E T A L C O P I N G, 2 4 G A M I N I M U M, A S <br /> POSTS, BOTH SIDES CAP FLASHING REQUIRED FOR SPANS <br /> OF LADDER � � 4" HEMMED DRIP EDGE � Z „ a Q � a � <br /> I I COUNTERFLASHING M � 1 1/8 CONTINUOUS PT PLYWOOD a <br /> ROOF HATCH PER � � 70 INSULATED CURB FASCIA a a a a <br /> DTL. 16/A8.1 � � o ASSEMBLY, FASTENED � RIGID INSULATION, STAGGERED JOINTS \ <br /> I I o PER MANUFACT�RER'S � � � <br /> I I �� � RECOMMENDATIONS CONTINUOUS 2X NAILER �� I <br /> I I 2X BLOCKING, PT WOOD SHEATHING <br /> o TPO ROOFING � �' c � � t e � � � <br /> MEMBRANE OVER RIGID PT BLOCKING 4 <br /> 1/2" ��2�� HORIZ REVEAL <br /> INSULATION WOOD TOP PLATE, PER STRUCTUR,4L <br /> 0 2505 Third Avenue <br /> Q Suite 324 <br /> � o CHANGE IN PAINT COLOR Seattle, WA 98'12'I <br /> � — — — <br /> CONTINUOUS GALVANIZED CLEAT �, � z <br /> a Q a � � � 206_720_700'I phone <br /> o TILT UP CONCREfE PANEL ��2�� 206.720.2949 fax <br /> a <br /> www_craftarch itects.com <br /> ° DESIGN BASIS: <br /> ��/ 2X PURLIN R-35, UP TO 7" OF RIGID TALL HOFiIZCJNTAL R VEAL 1 I �. V RTICAL FiEVEAL <br /> o I I �. RC�OF HATCH �P. ROOF SECTI�N INSULATION: CONFIRM WITH ENERGY Q — � , � <br /> �� 1 1/2"=1'-0" 12 1 1/2"=1'-0'� CODE COMPLIANCE TABLE ON �J 3 -1 -0 3 =1 -0 <br /> �� , ,. <br /> COVERSHEET <br /> � — TPO ROOF - EXTEND DOWN <br /> ROOF JOISTS VENT PIPE TO 1 BELOW T.O. <br /> 1 2� PLYWOOD <br /> BEYOND TPO PIPE BOOT, CONCRETE SHEATHING, PAINT <br /> � TO ACCOMMODATE PIPE RIGID INSULATION, BLACK <br /> SIZES FROM 1" TO 6" STAGGERED JOINTS � � CONCRETE WALL <br /> PANEL � o <br /> o SECURE PER 2X6 CONTINUOUS WOOD a . <br /> MANUFACTURER'S NAILERS <br /> LADDER CAGE INSTALLATION - � a � � � <br /> o REQUIREMENTS 6" MEfAL STUDS — � <br /> Z FLASHING - OVERLAP Q a � W <br /> � CONTINUOUS WELD "'o CONTINUOUS GUTTER, MIN. 3" a � � <br /> � TPO ROOF SYSTEM I WOOD BLOCKING PER � N � � . CONCRETE WALL � � T <br /> ° � PANEL Q (n J•� <br /> STRUCTURAL / \ � � <br /> PAINTED�SDDER � PRE-FINISHED MEfAL GUTfER, � � � " v <br /> � SEE EXTERIOR ELEVATIONS 1/4" � � � <br /> RIGID INSULATION BIRDSCREEN � � � Q a � N � REVEAL <br /> a o Q � �SEE ELEVATIONS R " <br /> �, „ _ � ` <br /> �` �� � Q N � � � � <br /> � FLASHING - EXTEND TO 1 N � <br /> d- STEEL ANGLE PAINTED �^ � <br /> 0 8" BELOW T.O. CONC W INSET CONTINUOUS � � PER EXTERIOR � V, <br /> � WOOD SHEATHING � SOFFIT VENT WITH �2� <br /> j SEALANT BUG SCREEN 1 1/2" ELEVATIONS a aa <br /> CONTINUOUS STEEL ANGLE MASONRY FASTENERS � <br /> PER STRUCTURAL 6" AT 48° ON CENTER, > <br /> � Q 1 X6 WOOD CEDAR BOARD PAINT TO MATCH �. Q W <br /> TILT-UP CONCRETE PANEL, FRAME AROUND STEEL ANGLE <br /> 0 o a TYP. PERIMEiER, FINISH PER <br /> � DOWNSPOUT BEYOND WALLS SECTIONS <br /> �o <br /> ° i ROOF VEIVT TYP. R4OF � CONTINUOUS GU ER �DGE � f'AN L OPENING TYP. HORIZ�NTAL REVEAL <br /> 2�-7" � 3"=1'-0" � 3"=1'-p,. <br /> 1� � ��2��=�'-0" 11 1 1/2"=1'-p» <br /> 0 <br /> � CONSULTANT <br /> a <br /> � FIXED SKYLIGHT � <br /> 2X WOOD CURB WITH FLASHING a <br /> o � SLOPED PT BLOCKING <br /> EXTEND PARTITION � o � RIGID INSULATION a � <br /> TO CREATE PARTIAL K' ROOF ASSEMBLY <br /> HEIGHT GUARDRAIL 1 1/8" CONTINUOUS PT a <br /> AT PLATFORM ° SIMPSON LTP4 OR EQUIVALENT Q Q �n PLYWOOD FASCIA a . a CONCRETE WALL PANEL Q Q CONCRE�E WALL <br /> FRAMING PLATE <br /> a TPO ROOF, WRAP OVER TOP a . <br /> WOOD BLOCKING OF BLOCKING AND DOWN a a a PANEL <br /> ° � a <br /> i �o RIGID INSULATION, STAGGER JOINTS � FACE OF PLYWOOD a SEALANT 8c <br /> "' � METAL COPING QQ a � BACKER ROD <br /> LADDER TO MEET ALL ° a a _ GHANGE IN PAINT COLOR,_TYP_ a <br /> — — — — — <br /> CURRENT OSHA SAFEfY a � a a �os� <br /> REQUIREMENTS a R���sT�R�� - <br /> Q . a ARCHIT£CT <br /> + + TILT-UP CONCRETE N -- � <br /> PANEL a � „ <br /> PAINTED STEEL 1 2' 1 2" �''���� '�+�+��rQr� <br /> LADDER Q . a a . a / ��2 ��n cRa{r �: <br /> PLYWD DECK - <br /> FLOOR OVER MEfAL 3/8"x 2 1/2" FB Q a <br /> JOISTS BEYOND, SIDE RAILS <br /> SEE PARTITION <br /> Submittals/Revisions: <br /> TYPES: SHEET A8.2 1 1/2" <br /> RUNGS �THR�U ��. �IX D SKYLI HT �UR� '��/ /� ��. r f�I N� T � � FOR PERMIT 05/04/16 <br /> SIDE RAILS � i I I �. �A�/`''i�E� SECTI�N � R/`1N ITI�N ��/�1N I I . �UTSI� C��N � <br /> PARTITION, �� 3"=1'-0" I� » > » `� 3"=1'-0" (AT HORIZONTAL REVEAL) � 3"=1'-0" <br /> PER PLAN 1 1/2 =1 —0 <br /> 0 <br /> + + � MEfAL COPING COVER <br /> ' a (12'-0" LENGTHS, MIN.) <br /> WOOD NAILER FINISH PER EXTERIOR Q CONCRETE WALL <br /> � ° ` ELEVATIONS a PANEL <br /> SEALANT <br /> 3'-6' FLASHING CHANNEL TPO MEMBRANE � <br /> � 12" WIDE 20 GA GLAV. \D� Q 1/4" <br /> - 5/8" � EXP BOLT W/2 3/4" MIN ANCHOR CLIPS 4'-0" O.C. '� <br /> EMBED, 3 EA FRAME FASTENERS a Q `L <br /> - ,� , � WIDE CONCEALED SPLICE �� <br /> C' PANEL PLATE AT EACH JOINT , a � ,���` � a <br /> 8"x3"x1/4"x3" LG = HIGH COUNTOUR VENTIIATED STRINGER ¢ a � N � CONCREfE WALL Sheet Title: EXTERIOR DETAILS <br /> NGLE BRACKEfS � �i °- � a � � `� �- --- -- ' ---- - \ a PANEL <br /> TOP & BOTfOM � � � � a. � � �O � M -'_ , � _ a <br /> � „ � w Z � M p � � �p <br /> 4-0 OC MAX F °° HAT SECTION CHANNEL W/MOUNTING � � M � a a �\ SEALANT & <br /> 3 ��4 + � � °, a BRACKET � 4'-0° O.C. Z N� � a Q Q. Q Ll a Q Q B A C K E R R O D Date: 05�04/16 <br /> m <br /> J a` d.. ° < � ;a. °.` aT ° .a, � EDGE OF CANOPY BEYOND � ° � � . �' ° � Design: <br /> Q ` . �. . . . a °� ..° : e 'a a . °oe M ° a : MASONRY FASTENERS N <br /> � 11=111=111=1 I 1=111=111=1 I I-111=111=111=111=111=111=111=111=111=111=111=111=111=111=111-TI-I I I� o. � „ <br /> � 111=111=111=111=111=111=111=111=111-111=111=111=111=111-111=111=111=111=111=111=111=111=111=1 STEEL ANGLE PAINTED PER C SEALANT & � /2 Drawn: <br /> � I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I-i l l-I I I-I I I-I I I-I I I EXTERIOR ELEVATIONS � BACKER <br /> ° I I I-I I I-I I I-I I I-I I1=1I 1=1 I I-I I 1=1 I I-I I I-I I I-I I I I I I-I I I-I I I-I I 1=1 I 1=1 I 1=1 I 1=1 I 1=1 I 1=1 I 1=1 I I-I � °4. � » 3/8" SPACE I� ACTUAL WALL WIDTH �� R, 1/2' /2" HORIZ. REVEAL <br /> W i i=i i i-i i i-Ti=i i i-i i i-iTi=i i i=Ti=Ti=i i i=i i i=i i i=iT_I=Ti=iTi-i i i=i i i=Ti=i i i_i i i-i i i=i i i=i i i a 4 -0 <br /> W I_II-111=111—III—III—III—III-111=111-111=111=111=111—III-111=111=111=111=111-111=111=111=111—i PROVIDED FOR (VARIES) � ��2» Project No: 15-198 <br /> II—III—III—III-111=111=111—III-111=111-111=111=111-111=111=111=111=111=111=111—I_TI-111=111—III WALL VARIATIONS » <br /> MASONRY FASTENERS AT 48" <br /> `" I_I I—I I I—I I I—I I I—I I1=1I I—I I I—I I I—I I I—I I I—I I I—I I 1=1 I I—I I I—I I I—I I I—I I I—I I I—I I I—I I I,I I I—I I I—I I I-1 1 1/ <br /> Q ��—iii-111,-111-111-111,=111=111-111=11i—lii=iTi=iTI-111=111-111-1T_I,;,111,;,111—���— 4° NOTE: ON CENTER, PAINT TO Approved: <br /> � PANEL COLOR TO MATCH MAIN MATCH STEEL ANGLE, TYP. 6�� <br /> � BODY FRAME <br /> Building No: BUILDING A <br /> � L�Q�� .��1 T� I-1�� �� L ���I� CHI V�P 1 . I I f . COP�I VG �C I H�� r L/`�I V � N�fl I �oflN fl �o�N� �. 1 HN � �oIN� <br /> � 17 , 2»=,�-a�� 13 ., , ,. ., > » ., , » <br /> 0 <br /> � 1/2"=1'-p» <br /> 3 =1 -0 � 3 =1 -0 � 3 =1 -0 Sheet No: . <br /> � <br /> � COPYRIGHT CRAF7 ARCHITECTS 2016 <br />