Laserfiche WebLink
NE 1 /4 , SECTI0 �1 35 , TOWNSHIP 29 �IORTH , RAI� GE 4 EAST, W . M . � � <br /> ENGINEERING <br /> 250 4TH AYE. S.� SUITE 200 <br /> EDMONDS, WASHINGTON 98020 <br /> PHONE (425) 778-8500 <br /> PIPE ANCHORS TO BE SECURED TO THE FAX (425� 778-5536 <br /> EXISTING SLOPE PER MANUFACTURES <br /> RECOMMENDATIONS OR @ MAXIMUM <br /> SPACING OF 30'OC <br /> 6" PVC CAP W/FERNCO <br /> COUPUNG ATTACHED TO <br /> 6"�HDPE W/STAINLESS <br /> STEEL PIPE CLAMPS CONTROLLED SURFACE FLOW <br /> TOWARDS RAILROAD DITCH <br /> FILTER FABRIC MATERIAL 36" MIN WIDE �'b°� �° �° � <br /> ROLLS. USE STAPLES OR WIRE RINGS TO ° oq�o�O�� �'b�� �bv�� �'b�� s�a`a <br /> ATTACH FABRIC TO WIRE.JOINTS IN FILTER b � o� ° o� �,o`� �oy� ��b <br /> FABRIC SHALL BE SPLICED AT POSTS. FIITER FABRIC b �'b' d'a� �°p og' p <br /> 2"x2" BY 14 GA.WIRE MATERIAL �bv `'" <br /> �G GU jLt <br /> FABRIC OR EQUIVALENT 2"x2" BY 14 GA WIRE 11" 8„ C}�,�,p� �As�r,�,� <br /> FABRIC OR EQUIV IF <br /> STANDARD STRENGTH 1�-11" H� �' • <br /> FABRIC IS USED ? Q 3��6�� <br /> z � � � <br /> �� � � � ���� ti� <br /> N N m CUT OUT UPPER HALF Cs <br /> � �x_ <br /> PROFILE OF EACH END CAP FOR SSI�IVAL � <br /> e; _ , ., 6"x6"MIN rRENCH ' WEIR EFFECT <br /> , �,��r , � � . ._._ � '�.,_.�. :� �~�-��— BACKFILLTRENCH WITH — <br /> _ �__.__ 06/2�l I� <br /> __ _� BURY BOTTOM OF FILTER NATIVE SOIL OR 3/4" 1 1/2 <br /> MATERIAL IN 6"x6"TRENCH __ ? WqSHED ROCK ° a� ° o� o - <br /> � o0 15/8"x 3" 1�2"q,j ORIFICE � � �b o�°0°4' N <br /> 6 MAX <br /> � 6",TYP ♦ + SLOTTED HOLE @ 6��O� �,p o� _ o o� <br /> 1 1/2�� d'e - cPb ,1 �� o <br /> 2"x4"WOOD POST ALT: o - �� ^� 1'-6" <br /> 2"x4"WOOD POSTS,STANDARD S T E E L F E N C E P O S T S � + + � � �� 0 � \\�\\�_ ��� 0 6 FUSED HDPE PIPE <br /> OR BETTER OR EQUAL b o �o� � � � � o " <br /> ALTERNA7E:STEEL FENCE POSTS � �— <br /> + , o� <Pb ANCHORED TO INSIDE OF <br /> cPb �'O �°p�' d'O4' �'O �'° CATCH BASIN PER MFR d <br /> a� NOTE: RECOMMENDATION � <br /> SILT FENCE NOTES: 7° PL 3/16 x 7 x 1'-0" � 0 CATCH BASIN&ANCHORAGE � N a <br /> (3) 1/2"�b THRU MAY BE ADIUSTED 1N THE FIELD � -� Z <br /> 1. THE FILTER FABRIC SHALL BE MIRAFI 700X OR APPROVED EQUAL,AND SHAIL BE PURCHASED IN A CONTINUOUS ROlL BOLTS EA SIDE � °4' ° o`� �� W/ENGINEER APPROVAL. m Q � � <br /> CUT TO THE IENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN 101NTS ARE NECESSARY, FILTER CLOTH SHALL b <br /> 1/2 �6 DRILLED HOLES @ N <br /> BENT PL 1/8" PROVIDE TO '' 6"OC. LONGITUDINALLY HDPE FLANGE N m <br /> BE SPLICED TOGETHER ONLY AT A SUPPORT POST,WITH A MINIMUM 6 INCH OVERLAP,AND BOTH ENDS SECURELY in > <br /> MATCH OUTSIDE � _ OFFSET TOP&BOTTOM INSlDE CATCH BASIN Z ~ � w � <br /> FASTENED TO THE POST. O m aC vr <br /> DIAMETER OF HDPE PIPE N � � ROWS BY 2" <br /> 2. T H E S I L T F E N C E S H A L L B E I N S T A L L E D T O F O L L O W T H E C O N T O U R S(W H E R E F E A S I B L E). T H E F E N C E P O S T S S H A L L B E S E C T I O N A-A ° o� � _ � 1— � � p W <br /> SPACED A MAXIMUM OF 6 FEET APART AND DRIVEN SECURELY INTO THE GROUND(MINIMUM OF 181NCHES). � � N � <br /> 3. A SHALLOW TRENCH SHALL BE EXCAVATED, ROUGHLY 6 fNCHES WIDE AND 61NCHES DEEP, UPSLOPE AND ADIA C E N T G A L V A N I Z E D S A D D L E A S �b Z° o�, BURLINGTON CATCH � � � � H � H <br /> TO THE WOOD P O ST S T O A L L O W T H E L O W E R E D G E O F T H E F I L T E R F A B R I C T O B E S E C U R E D W I T H G R A V E L. S P E C I F I E D O R � � BASIN BY CUZ CONCRETE <br /> 6"Q�HDPE PIPE � _ _ __ � <br /> 4. WHEN FILTER FABRIC NOT AS STRONG AS MIRAFI 700X IS USED,A WIRE MESH SUPPORT FENCE SHALL BE FASTENED PRE-MANUFACTURED EQUAL �� b OR APPROVED EQUAL 6" P V C F R O M R O O F � � � J � <br /> SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAW-DUTY WIR E S T A P L E S A T L E A S T 1 I N C H L O N G,T I E W I R E S ON SIOPE 6°WELDED TEE - &FTG DRAINS w Z w Q w <br /> o m a o c a <br /> OR HOG RINGS. THE WIRE MESH SHAII EXTEND INTO THE SHALLOW TRENCH A MINIMUM OF 4 INCHES AND SHALL A A � �?O�' — <br /> d"' <br /> NOT EXTEND MORE THAN 36 INCHES ABOVE THE ORIGINAL GROUND SURFACE. ;.� COLLAR END CAP W/ �° o� � �a o� — _ � <br /> 5. THE MIRAF1700X FIITER FABRIC SHALL BE STAPLED OR WIRED TO THE FENCE,AND AT LEAST 181NCHE5 OF THE FABRIC �Z���j p�pE� FERNCO COUPLING �'' o �'b , „ -- --- ^� ^ ^ ^ ^ <br /> PRIMED L6 x 4 x 1/4 x 1-6 N � � � � <br /> SHALI BE 6URIED IN THE SHALLOW TRENCH. THE FILTER FABRIC SHALL NOT EXTEND MORE THAN 36 INCHES ABOVE &PIPE CLAMPS <br /> ° ��' LONG W/(3)5J8"Q�HILTI KWIK --- �-+ Q c��l N O N <br /> THE ORIGINAL GROUND SURFACE AND SHALL NOT BE STAPLED TO TREES. a � <br /> 6. WHEN EXTRA-STREN6TH FILTER FABRIC(MIRAFI 700X OR EQUAL)AND FOUR(4')POST SPACING IS USED,THE WIRE B O L T T Z W/4"E M B E D M E N T � -- --- -- �, � M M � t�C <br /> M E S H S U P P O R T F E N CE MAY BE ELIMINATED. IN SUCH A CASE,THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO 1 4 " � z�� � o O O O <br /> THE POSTS WITH ALL OTHER PROVISIONS OF NOTE 5 APPLYING. o o� <br /> � o�o� �a� o � <br /> 7. THE TRENCH SHALL BE BACKFILLED WITH NATIVE SOIL OR 3/4"-1.5"WASHED ROCK. ' � Y <br /> b _ ] e � " <br /> - ._ - � N �� d. . ' Q � ' �� ,Q . �� , . _._. __.._.. � <br /> 8. FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE ' � ' '' � � I I — — I I—I —I � <br /> UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED.THE NEWLY DISTURBED AREAS RESULTING FROM SILT FENCE I��I I I� � I ' ° � � VV d UU � ` � <br /> REMOVAL SHALI BE IMMEDIATELY SEEDED AND MULCHED,OR OTHERWISE PERMANENTLY STABILIZED TO THE MATERIAL TO BE ASTM - ° � ` " <br /> A36 GALVANIZED r-- ------ ------- ______________. �.n. � <br /> SATISFACTION OF THE CIVIL INSPECTOR. PLAN VIEW � � � � � DESIGN: VD <br /> 9. SILT FEfVCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED AFTER FABRICATION <br /> RAINFALL.ANY REQUIRED REPAIRS SHAIL BE MADE IMMEDIATELY. PER ASTM A153 2" M{NUS CLEAN EXISTING 6" DRAWN: JCS <br /> 1 1J2"x 6` PIPE <br /> 10.MAINTENANCE:ANY DAMAGED OR CLOGGED FENCE SHALL BE REPAIRED/REPLACED IMMEDIATELY.SEDIMENT MUST STAKES EA SIDE CRUSHED ROCK PAD CONCRETE WALL <br /> BE REMOVED WHEN THE SEDIMENT DEPTH IS 6 INCHES OR GREATER. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF PIPE CHECK: GAG <br /> FLATTEN TO POINT JOB NO: 17041 .20 <br /> OF THE FENCE,THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENTTRAP OR POND. <br /> DATE: 03/20/17 <br /> SILT FENCE PIPE ANCHOR DETAIL DRAIN DIFFUSER TEE DETAIL BURLINGTON CATCH BASIN DETAIL <br /> 1 SCALE: 1/2" = 1'-0 � SCAIE: NTS � SCALE: NTS � SCALE: 1" = 1'-0" <br /> W <br /> �? <br /> Q <br /> Z <br /> � � � <br /> � J ---� <br /> - <br /> W <br /> M <br /> Z � N ~ <br /> W � W <br /> o � rn � <br /> � t.�a.t � Q W <br /> � � 3 (� <br /> � Q <br /> w � � Z <br /> � w ._ <br /> �- Q <br /> U � > � � <br /> tn �- w p � <br /> � <br /> SHEET: <br /> ■ <br />