Laserfiche WebLink
Geotechnical Engineering Evaluation NGA File No. 1008917 <br /> Cooley Smiles Commercial Development October 3,2017 <br /> Everett,Washington Page 8 <br /> encountered in the unexplored areas of the site. Where undocumented fill or less dense soils are <br /> encountered at footing bearing elevation, the subgrade should be over-excavated to expose suitable <br /> bearing soil. The over-excavation may be filled with structural fill, or the footing may be extended down <br /> to the competent native soils. If footings are supported on structural fill, the fill zone should extend <br /> outside the edges of the footing a distance equal to one half of the depth of the over-excavation below the <br /> bottom of the footing. <br /> All footings should extend at least 18 inches below the lowest adjacent finished ground surface for frost <br /> protection and bearing capacity considerations. Foundations should be designed in accordance with the <br /> 2015 IBC. Footing widths should be based on the anticipated loads and allowable soil bearing pressure. <br /> Water should not be allowed to accumulate in footing trenches. All loose or disturbed soil should be <br /> removed from the foundation excavation prior to placing concrete. <br /> For foundations constructed as outlined above, we recommend an allowable design bearing pressure of <br /> not more than 2,500 pounds per square foot (psf) be used for the design of footings founded on the <br /> medium dense or better native glacial soils or rock spalls extending to the competent native material. The <br /> foundation bearing soil should be evaluated by a representative of NGA. We should be consulted if <br /> higher bearing pressures are needed. Current IBC guidelines should be used when considering increased <br /> allowable bearing pressure for short-term transitory wind or seismic loads. Potential foundation <br /> settlement using the recommended allowable bearing pressure is estimated to be less than one-inch total <br /> and 1/2-inch differential between adjacent footings or across a distance of about 20 feet, based on our <br /> experience with similar project. <br /> Lateral loads may be resisted by friction on the base of the footing and passive resistance against the <br /> subsurface portions of the foundation. A coefficient of friction of 0.35 may be used to calculate the base <br /> friction and should be applied to the vertical dead load only. Passive resistance may calculated as a <br /> triangular equivalent fluid pressure distribution. An equivalent fluid density of 200 pounds per cubic foot <br /> (pcf)should be used for passive resistance design for a level ground surface adjacent to the footing. This <br /> level surface should extend a distance equal to at least three times the footing depth. These recommended <br /> values incorporate safety factors of 1.5 and 2.0 applied to the estimated ultimate values for frictional and <br /> passive resistance, respectively. To achieve this value of passive resistance, the foundations should be <br /> poured "neat" against the native medium dense soils or compacted fill should be used as backfill against <br /> the front of the footing. We recommend that the upper one foot of soil be neglected when calculating the <br /> passive resistance. <br /> NELSON GEOTECHNICAL ASSOCIATES, INC, <br />